Graphite-based microextraction by packed sorbent for online extraction of β-blockers from human plasma samples

被引:19
作者
Abuzooda, Thana [1 ]
Amini, Ahmad [2 ]
Abdel-Rehim, Mohamed [1 ]
机构
[1] Stockholm Univ, Dept Analyt Chem, S-10691 Stockholm, Sweden
[2] Swedish Drug Agency, S-75103 Uppsala, Sweden
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 992卷
关键词
Graphitic sorbent; Microextraction by packed sorbent; beta-Blocker; Plasma samples; CHROMATOGRAPHY-MASS SPECTROMETRY; SOLID-PHASE EXTRACTION; HUMAN URINE SAMPLES; LIQUID-CHROMATOGRAPHY; SYRINGE MEPS; LOCAL-ANESTHETICS; STATIONARY-PHASE; LC-MS/MS; CARBON; QUANTIFICATION;
D O I
10.1016/j.jchromb.2015.04.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work a new graphitic material (Carbon-XCOS) was used as a sorbent for microextraction by packed sorbent (MEPS).The beta-blockers metoprolol and acebutolol in plasma samples were extracted and detected online using Carbon-MEPS syringe and liquid chromatography and tandem mass spectrometry (LC-MS/MS). Factors affecting the MEPS performance such as conditioning, washing and elution solutions were investigated. The validation of the bioanalytical method was performed using human plasma. The standard curve ranged from 10 to 2000 nM and the lower limit of quantification (LLOQ) was set to 10 nM. The method validation showed good accuracy and precision for the quality control (QC) samples at three concentration levels (30, 800 and 1600 nM). The accuracy values of the QC samples were in the range of 86-108% (n = 18). The precision values of intra- and inter-day for QC samples ranged from 4.4% to 14.4% (RSD) for the both studied analytes. The coefficient of determination (R-2) values were >= 0.999 (n = 3). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 90
页数:5
相关论文
共 50 条
  • [41] Novel oligonucleotide-based sorbent for the selective extraction of cadmium from serum samples
    Gignac, Fanny
    Delaunay, Nathalie
    Pichon, Valerie
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 237
  • [42] Boron nitride nanotubes for extraction of angiotensin receptor blockers from human plasma
    Batista, Jessica Mauricio
    Vieira Diniz, Melina Luiza
    da Silva, Wellington Marcos
    Gloria, Maria Beatriz A.
    Barros de Sousa, Edesia Martins
    Fernandes, Christian
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 221
  • [43] A method based on microextraction by packed sorbent-programmed temperature vaporizer-fast gas chromatography-mass spectrometry for the determination of aromatic amines in environmental water samples
    del Nogal Sanchez, Miguel
    Perez Sappo, Cristina
    Perez Pavon, Jose Luis
    Moreno Cordero, Bernardo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (6-7) : 2007 - 2015
  • [44] An analytical strategy for designer benzodiazepines and Z-hypnotics determination in plasma samples using ultra-high performance liquid chromatography/tandem mass spectrometry after microextraction by packed sorbent
    Ares-Fuentes, A. M.
    Lorenzo, R. A.
    Fernandez, P.
    Carro, A. M.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 194
  • [45] Efficient discrimination and removal of phospholipids during electromembrane extraction from human plasma samples
    Vardal, Linda
    Gjelstad, Astrid
    Huang, Chuixiu
    Oiestad, Elisabeth Leere
    Pedersen-Bjergaard, Stig
    BIOANALYSIS, 2017, 9 (08) : 631 - 641
  • [46] First liquid chromatographic method for the simultaneous determination of amiodarone and desethylamiodarone in human plasma using microextraction by packed sorbent (MEPS) as sample preparation procedure
    Rodrigues, Marcio
    Alves, Gilberto
    Rocha, Marilia
    Queiroz, Joao
    Falcao, Amilcar
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 913 : 90 - 97
  • [47] Microextraction in packed syringe/liquid chromatography/electrospray tandem mass spectrometry for quantification of acebutolol and metoprolol in human plasma and urine samples
    El-Beqqali, Aziza
    Kussak, Anders
    Blomberg, Lars
    Abdel-Rehim, Mohamed
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (04) : 575 - 586
  • [48] A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples
    Moein, Mohammad Mahdi
    Jabbar, Dunia
    Colmsjo, Anders
    Abdel-Rehim, Mohamed
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1366 : 15 - 23
  • [49] Screening of Cocaine and Its Metabolites in Human Urine Samples by Direct Analysis in Real-Time Source Coupled to Time-of-Flight Mass Spectrometry After Online Preconcentration Utilizing Microextraction by Packed Sorbent
    Jagerdeo, Eshwar
    Abdel-Rehim, Mohamed
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (05) : 891 - 899
  • [50] Development of new extraction method based on liquid-liquid-liquid extraction followed by dispersive liquid-liquid microextraction for extraction of three tricyclic antidepressants in plasma samples
    Farajzadeh, Mir Ali
    Abbaspour, Maryam
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (08)