This paper presents an experimental measurement of the thermal conductivity of bovine cortical bone by an improved parallel plate method to increase the accuracy of the measurement. An experimental apparatus was designed to measure the thermal conductivity of the cortical bone using a reference material with a known thermal conductivity by the heat transfer through the samples. To improve the measurement accuracy, a reference material was selected as quartz, which is of the same order of magnitude of the thermal conductivity of bovine cortical bone reported in the existing literature. Additionally, the temperatures at the heat source and heat sink were set to +/-5 degrees C from the ambient temperature to reduce the inevitable heat loss in the measurement. The temperature offset was determined numerically. The current experimental measurement was validated by an in-house finite-difference numerical program. The heat loss in the measurement was predicted from the numerical program. The thermal conductivity of the bovine cortical bone was then determined to be 0.55 +/- 0.02 W/mK with compensating heat loss.
引用
收藏
页数:7
相关论文
共 11 条
[1]  
[Anonymous], 2002, Bones: Structure and Mechanics
[2]   MEASUREMENTS OF THERMAL-PROPERTIES FOR HUMAN FEMORA [J].
BIYIKLI, S ;
MODEST, MF ;
TARR, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1986, 20 (09) :1335-1345
[3]  
CLATTENBURG R, 1975, J BIOMED MATER RES, V9, P169
[4]   Measurement of thermal conductivity of bovine cortical bone [J].
Davidson, SRH ;
James, DF .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (10) :741-747
[5]   HEAT CAUSED BY DRILLING CORTICAL BONE - TEMPERATURE MEASURED INVIVO IN PATIENTS AND ANIMALS [J].
ERIKSSON, AR ;
ALBREKTSSON, T ;
ALBREKTSSON, B .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06) :629-631
[6]  
Lee J. E, 2016, 2016 ASME INT MECH E
[7]   An experimental investigation on thermal exposure during bone drilling [J].
Lee, JuEun ;
Ozdoganlar, O. Burak ;
Rabin, Yoed .
MEDICAL ENGINEERING & PHYSICS, 2012, 34 (10) :1510-1520
[8]   A new thermal model for bone drilling with applications to orthopaedic surgery [J].
Lee, JuEun ;
Rabin, Yoed ;
Ozdoganlar, O. Burak .
MEDICAL ENGINEERING & PHYSICS, 2011, 33 (10) :1234-1244
[9]   MEASUREMENT OF THE THERMAL-CONDUCTIVITY OF CORTICAL BONE BY AN INVERSE TECHNIQUE [J].
MOSES, WM ;
WITTHAUS, FW ;
HOGAN, HA ;
LASTER, WR .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1995, 11 (01) :34-39
[10]  
Sisljagic V, 2010, PERIOD BIOL, V112, P59