A soft x-ray beamline capable of canceling the performance impairment due to power absorbed on its optical elements

被引:20
作者
Reininger, Ruben [1 ]
Kriesel, Ken [2 ]
Hulbert, S. L. [3 ,4 ]
Sanchez-Hanke, Cecilia [3 ,4 ]
Arena, D. A. [3 ,4 ]
机构
[1] Sci Answers & Solut, Madison, WI 53711 USA
[2] Univ Wisconsin, PSL, Stoughton, WI 53589 USA
[3] Brookhaven Natl Lab, NSLS, Upton, NY 11973 USA
[4] Brookhaven Natl Lab, NSLS II, Upton, NY 11973 USA
关键词
D O I
10.1063/1.2897587
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present an entrance slitless beamline design capable of maintaining its very high performance in terms of energy resolution (>10(4)) and spot size (4 x 4 mu m(2)) at the sample position despite being exposed to more than 2.15 kW of undulator radiation and a maximum power density on the optics of more than 0.9 W/mm(2). Ray tracing simulations of this beamline under the worst-case thermal deformations of the optical element surfaces verify that appropriate focusing corrections are able to cancel the deleterious effects of these deformations. One of the necessary conditions for this cancellation is to illuminate the optical elements with a larger solid angle than the undulator's central cone, which contains the usable photons but is considerably smaller than the angular power distribution. (C) 2008 American Institute of Physics.
引用
收藏
页数:6
相关论文
共 17 条
[1]   Design of a variable-included-angle Monk-Gillieson monochromator with varied-line-spacing gratings [J].
Amemiya, K ;
Ohta, T .
JOURNAL OF SYNCHROTRON RADIATION, 2004, 11 :171-176
[2]   PERFORMANCE OF A SX-700 MONOCHROMATOR EXPOSED TO WIGGLER RADIATION - COUPLED RAY-TRACING AND FINITE-ELEMENT APPROACH [J].
DECASTRO, ARB ;
REININGER, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (01) :135-141
[3]  
DECASTRO ARB, 1991, REV SIC INSTR, V63, P1317
[4]  
Elleaume P., 2003, UNDULATORS WIGGLERS
[5]   Extended SX-700 type monochromator combining normal and grazing incidence optics for a new undulator beamline at SLS [J].
Flechsig, U ;
Patthey, L ;
Quitmann, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :479-481
[6]   Plane-grating monochromator at BESSY II using collimated light [J].
Follath, R ;
Senf, F ;
Gudat, W .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :769-771
[7]   New plane-grating monochromators for third generation synchrotron radiation light sources [J].
Follath, R ;
Senf, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 390 (03) :388-394
[8]   Varied line-spacing plane grating monochromator for undulator beamline [J].
Fujisawa, M ;
Harasawa, A ;
Agui, A ;
Watanabe, M ;
Kakizaki, A ;
Shin, S ;
Ishii, T ;
Kita, T ;
Harada, T ;
Saitoh, Y ;
Suga, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (02) :345-349
[9]  
HARADA T, 1984, P SOC PHOTO-OPT INST, V503, P114, DOI 10.1117/12.944821
[10]   SOFT-X-RAY MONOCHROMATOR WITH A VARIED-SPACE PLANE GRATING FOR SYNCHROTRON RADIATION - DESIGN AND EVALUATION [J].
ITOU, M ;
HARADA, T ;
KITA, T .
APPLIED OPTICS, 1989, 28 (01) :146-153