Effect of Depression on Mortality in Implantable Cardioverter Defibrillator Recipients-Findings from the Prospective LICAD Study

被引:25
作者
Tzeis, Stylianos [2 ,3 ]
Kolb, Christof [2 ,3 ]
Baumert, Jens [4 ]
Reents, Tilko [2 ,3 ]
Zrenner, Bernhard [2 ,3 ]
Deisenhofer, Isabel [2 ,3 ]
Ronel, Joram [4 ]
Andrikopoulos, George [5 ]
Ladwig, Karl-Heinz [1 ,4 ]
机构
[1] Helmholtz Zentrum Munchen, German Res Ctr Environm Hlth, Inst Epidemiol Epi 2, D-85764 Neuherberg, Germany
[2] Deutsch Herzzentrum Munich, Munich, Germany
[3] Tech Univ Munich, Fac Med, Med Klin Klinikum Rechts Isar 1, Munich, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Fac Med, Dept Psychosomat Med & Psychotherapy, D-8000 Munich, Germany
[5] Henry Dunant Hosp, Dept Cardiol, Athens, Greece
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2011年 / 34卷 / 08期
关键词
implantable cardioverter defibrillator; depression; mortality; ACUTE MYOCARDIAL-INFARCTION; CORONARY-ARTERY-DISEASE; SUDDEN CARDIAC DEATH; HEART-FAILURE; VENTRICULAR-ARRHYTHMIAS; HOSPITAL ANXIETY; SYMPTOMS; RISK; METAANALYSIS; PREVALENCE;
D O I
10.1111/j.1540-8159.2011.03081.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Depression predicts mortality in patients with coronary artery disease and heart failure. However, its effect on patient outcome in the presence of an implantable cardioverter defibrillator (ICD) has not been investigated. Methods: A total of 236 ICD patients (76 females, 58.6 +/- 14.0 years) were screened for depressive symptoms using the Hospital Anxiety and Depression Scale (HADS). The outcome measure was all-cause mortality and the prognostic effect of depression was evaluated with Cox proportional hazards regression analysis. Results: Fifty (21%) patients reported depressive symptoms (HADS score >= 8). Renal failure (odds ratio [OR] = 4.0, 95% confidence intervals [CI] = 1.47-10.87, P = 0.007), prior angina (OR = 2.1, 95% CI = 1.07-4.12, P = 0.03), but not the experience of ICD shocks were associated with baseline depressive symptoms. In a mean follow-up period of 6.1 +/- 2.5 years, 74 patients (31%) died. Mortality significantly increased from 45.1 deaths per 1,000 person-years among patients without depression to 80.3 deaths per 1,000 person-years in patients with depressive symptoms (P = 0.039). In the univariate model, depression (HADS score = 8) was a significant predictor of mortality (OR = 1.81, 95% CI = 1.1-3.0, P = 0.02). However, in the multivariate model, depression lost its prognostic significance. Conclusions: In our prospective patient cohort, one-fifth of ICD recipients reported depressive symptoms. Depression increased the absolute mortality risk but was not an independent predictor of mortality. (PACE 2011;34:991-997)
引用
收藏
页码:991 / 997
页数:7
相关论文
共 50 条
[41]   Protein Biomarkers Identify Patients Unlikely to Benefit From Primary Prevention Implantable Cardioverter Defibrillators Findings From the Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSE-ICD) [J].
Cheng, Alan ;
Zhang, Yiyi ;
Blasco-Colmenares, Elena ;
Dalal, Darshan ;
Butcher, Barbara ;
Norgard, Sanaz ;
Eldadah, Zayd ;
Ellenbogen, Kenneth A. ;
Dickfeld, Timm ;
Spragg, David D. ;
Marine, Joseph E. ;
Guallar, Eliseo ;
Tomaselli, Gordon F. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (06) :1084-U185
[42]   Kidney Dysfunction and Deterioration of Ejection Fraction Pose Independent Risk Factors for Mortality in Implantable Cardioverter-Defibrillator Recipients for Primary Prevention [J].
Kreuz, Jens ;
Horlbeck, Fritz ;
Schrickel, Jan ;
Linhart, Markus ;
Fimmers, Rolf ;
Mellert, Fritz ;
Nickenig, Georg ;
Schwab, Joerg Otto .
CLINICAL CARDIOLOGY, 2012, 35 (09) :575-579
[43]   Effect of SAcubitril/Valsartan on left vEntricular ejection fraction and on the potential indication for Implantable Cardioverter Defibrillator in primary prevention: the SAVE-ICD study [J].
Guerra, Federico ;
Ammendola, Ernesto ;
Ziacchi, Matteo ;
Aspromonte, Vittorio ;
Pellegrino, Pier Luigi ;
Del Giorno, Giuseppe ;
Dell'Era, Gabriele ;
Pimpini, Lorenzo ;
Santoro, Francesco ;
Floris, Roberto ;
Stronati, Giulia ;
Nigro, Gerardo ;
Paolisso, Pasquale ;
Guido, Alessandro ;
Maglia, Giampiero ;
Brunetti, Natale Daniele ;
Carbone, Angelo ;
Gravellone, Miriam ;
Antonicelli, Roberto ;
Cannone, Michele ;
Accogli, Michele ;
Dello Russo, Antonio ;
Palmisano, Pietro .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 2021, 77 (12) :1835-1842
[44]   Association between remote implantable cardioverter defibrillator monitoring and beta-blocker utilization: An analysis from the EFFECT study [J].
D'Onofrio, Antonio ;
Stabile, Giuseppe ;
Capucci, Alessandro ;
Amellone, Claudia ;
De Simone, Antonio ;
Leoni, Loira ;
Morani, Giovanni ;
Bianchi, Valter ;
Campari, Monica ;
Valsecchi, Sergio ;
Buja, Gianfranco .
JOURNAL OF TELEMEDICINE AND TELECARE, 2016, 22 (07) :383-390
[45]   Ventricular Arrhythmias Among Implantable Cardioverter-Defibrillator Recipients for Primary Prevention Impact of Chronic Total Coronary Occlusion (VACTO Primary Study) [J].
Nombela-Franco, Luis ;
Mitroi, Cristina D. ;
Fernandez-Lozano, Ignacio ;
Garcia-Touchard, Arturo ;
Toquero, Jorge ;
Castro-Urda, Victor ;
Fernandez-Diaz, Jose A. ;
Perez-Pereira, Elena ;
Beltran-Correas, Paula ;
Segovia, Javier ;
Werner, Gerald S. ;
Javier, Goicolea ;
Luis, Alonso-Pulpon .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (01) :147-154
[46]   Clinical Effectiveness of Cardiac Resynchronization and Implantable Cardioverter-Defibrillator Therapy in Men and Women With Heart Failure Findings From IMPROVE HF [J].
Wilcox, Jane E. ;
Fonarow, Gregg C. ;
Zhang, Yan ;
Albert, Nancy M. ;
Curtis, Anne B. ;
Gheorghiade, Mihai ;
Heywood, J. Thomas ;
Mehra, Mandeep R. ;
O'Connor, Christopher M. ;
Reynolds, Dwight ;
Walsh, Mary Norine ;
Yancy, Clyde W. .
CIRCULATION-HEART FAILURE, 2014, 7 (01) :146-153
[47]   Perceived support from healthcare professionals, shock anxiety and post-traumatic stress in implantable cardioverter defibrillator recipients [J].
Morken, Ingvild M. ;
Bru, Edvin ;
Norekval, Tone M. ;
Larsen, Alf I. ;
Idsoe, Thormod ;
Karlsen, Bjorg .
JOURNAL OF CLINICAL NURSING, 2014, 23 (3-4) :450-460
[48]   Early mortality in implantable cardioverter defibrillator patients: from randomized controlled trials to real life [J].
Koebe, Julia ;
Eckardt, Lars .
EUROPACE, 2009, 11 (06) :694-696
[49]   Clinical impact of implantable cardioverter-defibrillator in primary prevention of total mortality in non-ischaemic cardiomyopathy: results from a meta-analysis of prospective randomized clinical trials [J].
Romero, Jorge ;
Diaz, Juan Carlos ;
Grushko, Michael ;
Quispe, Renato ;
Briceno, David ;
Avendano, Ricardo ;
Golive, Anjani ;
Pina, Ileana ;
Natale, Andrea ;
Garcia, Mario J. ;
Jorde, Ulrich P. ;
Di Biase, Luigi .
EUROPACE, 2018, 20 :F211-F216
[50]   Sex differences in the course of implantable cardioverter defibrillator concerns (Results from the Danish national DEFIB-WOMEN study) [J].
Andersen, Christina M. ;
Johansen, Jens Brock ;
Wehberg, Sonja ;
Nielsen, Jens Cosedis ;
Riahi, Sam ;
Haarbo, Jens ;
Philbert, Berit T. ;
Pedersen, Susanne S. ;
DEFIB WOMEN Investigators .
JOURNAL OF PSYCHOSOMATIC RESEARCH, 2023, 164