Effect of Depression on Mortality in Implantable Cardioverter Defibrillator Recipients-Findings from the Prospective LICAD Study

被引:25
作者
Tzeis, Stylianos [2 ,3 ]
Kolb, Christof [2 ,3 ]
Baumert, Jens [4 ]
Reents, Tilko [2 ,3 ]
Zrenner, Bernhard [2 ,3 ]
Deisenhofer, Isabel [2 ,3 ]
Ronel, Joram [4 ]
Andrikopoulos, George [5 ]
Ladwig, Karl-Heinz [1 ,4 ]
机构
[1] Helmholtz Zentrum Munchen, German Res Ctr Environm Hlth, Inst Epidemiol Epi 2, D-85764 Neuherberg, Germany
[2] Deutsch Herzzentrum Munich, Munich, Germany
[3] Tech Univ Munich, Fac Med, Med Klin Klinikum Rechts Isar 1, Munich, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Fac Med, Dept Psychosomat Med & Psychotherapy, D-8000 Munich, Germany
[5] Henry Dunant Hosp, Dept Cardiol, Athens, Greece
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2011年 / 34卷 / 08期
关键词
implantable cardioverter defibrillator; depression; mortality; ACUTE MYOCARDIAL-INFARCTION; CORONARY-ARTERY-DISEASE; SUDDEN CARDIAC DEATH; HEART-FAILURE; VENTRICULAR-ARRHYTHMIAS; HOSPITAL ANXIETY; SYMPTOMS; RISK; METAANALYSIS; PREVALENCE;
D O I
10.1111/j.1540-8159.2011.03081.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Depression predicts mortality in patients with coronary artery disease and heart failure. However, its effect on patient outcome in the presence of an implantable cardioverter defibrillator (ICD) has not been investigated. Methods: A total of 236 ICD patients (76 females, 58.6 +/- 14.0 years) were screened for depressive symptoms using the Hospital Anxiety and Depression Scale (HADS). The outcome measure was all-cause mortality and the prognostic effect of depression was evaluated with Cox proportional hazards regression analysis. Results: Fifty (21%) patients reported depressive symptoms (HADS score >= 8). Renal failure (odds ratio [OR] = 4.0, 95% confidence intervals [CI] = 1.47-10.87, P = 0.007), prior angina (OR = 2.1, 95% CI = 1.07-4.12, P = 0.03), but not the experience of ICD shocks were associated with baseline depressive symptoms. In a mean follow-up period of 6.1 +/- 2.5 years, 74 patients (31%) died. Mortality significantly increased from 45.1 deaths per 1,000 person-years among patients without depression to 80.3 deaths per 1,000 person-years in patients with depressive symptoms (P = 0.039). In the univariate model, depression (HADS score = 8) was a significant predictor of mortality (OR = 1.81, 95% CI = 1.1-3.0, P = 0.02). However, in the multivariate model, depression lost its prognostic significance. Conclusions: In our prospective patient cohort, one-fifth of ICD recipients reported depressive symptoms. Depression increased the absolute mortality risk but was not an independent predictor of mortality. (PACE 2011;34:991-997)
引用
收藏
页码:991 / 997
页数:7
相关论文
共 50 条
[31]   Rates and predictors of appropriate implantable cardioverter-defibrillator therapy delivery: Results from the EVADEF cohort study [J].
Otmani, Akii ;
Trinquart, Ludovic ;
Marijon, Eloi ;
Lavergne, Thomas ;
Waintraub, Xavier ;
Lepiffier, Antoine ;
Chatellier, Gilles ;
Le Heuzey, Jean-Yves .
AMERICAN HEART JOURNAL, 2009, 158 (02) :230-237E1
[32]   Mortality Implications of Appropriate Implantable Cardioverter Defibrillator Therapy in Secondary Prevention Patients: Contrasting Mortality in Primary Prevention Patients From a Prospective Population-Based Registry [J].
Almehmadi, Fahad ;
Porta-Sanchez, Andreu ;
Ha, Andrew C. T. ;
Fischer, Hadas D. ;
Wang, Xuesong ;
Austin, Peter C. ;
Lee, Douglas S. ;
Nanthakumar, Kumaraswamy .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (08)
[33]   Effect of a Psychoeducational Intervention on Depression, Anxiety, and Health Resource Use in Implantable Cardioverter Defibrillator Patients [J].
Dunbar, Sandra B. ;
Langberg, Jonathan J. ;
Reilly, Carolyn M. ;
Viswanathan, Bindu ;
Mccarty, Frances ;
Culler, Steven D. ;
O'Brien, Marian C. ;
Weintraub, William S. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (10) :1259-1271
[34]   Long-term follow-up study of uncertainty and psychosocial adjustment among implantable cardioverter defibrillator recipients [J].
Mauro, Ann Marie P. .
INTERNATIONAL JOURNAL OF NURSING STUDIES, 2010, 47 (09) :1080-1088
[35]   Fifteen years' experience of implantable cardioverter defibrillator in children and young adults: Mortality and complications study [J].
Lewandowski, Michal ;
Syska, Pawel ;
Kowalik, Ilona ;
Maciag, Aleksander ;
Sterlinski, Maciej ;
Atenska-Pawlowska, Joanna ;
Szwed, Hanna .
PEDIATRICS INTERNATIONAL, 2018, 60 (10) :923-930
[36]   Fluoroscopic and Electrical Assessment of Implantable Cardioverter Defibrillator Leads: A Prospective Observational Study [J].
McKeag, Nicholas A. ;
Hodkinson, Emily C. ;
Noad, Rebecca L. ;
Kodoth, Vivek N. ;
Ashfield, Kyle ;
Wilson, Carol M. ;
McEneaney, David J. ;
Roberts, Michael J. D. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (11) :1538-1543
[37]   Multi-morbidity burden, psychological distress, and quality of life in implantable cardioverter defibrillator recipients: Results from a nationwide study [J].
Miller, Jennifer L. ;
Thylen, Ingela ;
Elayi, Samy C. ;
Etaee, Farshid ;
Fleming, Steve ;
Czarapata, Mary M. ;
Lennie, Terry A. ;
Moser, Debra K. .
JOURNAL OF PSYCHOSOMATIC RESEARCH, 2019, 120 :39-45
[38]   EFFECTS OF AEROBIC INTERVAL TRAINING ON MEASURES OF ANXIETY, DEPRESSION AND QUALITY OF LIFE IN PATIENTS WITH ISCHAEMIC HEART FAILURE AND AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR: A PROSPECTIVE NON-RANDOMIZED TRIAL [J].
Isaksen, Kjetil ;
Munk, Peter Scott ;
Giske, Rune ;
Larsen, Alf Inge .
JOURNAL OF REHABILITATION MEDICINE, 2016, 48 (03) :300-306
[39]   Dutch outcome in implantable cardioverter-defibrillator therapy (DO-IT): registry design and baseline characteristics of a prospective observational cohort study to predict appropriate indication for implantable cardioverter-defibrillator [J].
van Barreveld, M. ;
Dijkgraaf, M. G. W. ;
Hulleman, M. ;
Boersma, L. V. A. ;
Delnoy, P. P. H. M. ;
Meine, M. ;
Tuinenburg, A. E. ;
Theuns, D. A. M. J. ;
van der Voort, P. H. ;
Kimman, G. P. ;
Buskens, E. ;
Tijssen, J. P. G. ;
Bruinsma, N. ;
Verstraelen, T. E. ;
Zwinderman, A. H. ;
van Dessel, P. H. F. M. ;
Wilde, A. A. M. .
NETHERLANDS HEART JOURNAL, 2017, 25 (10) :574-580
[40]   Association between atrial fibrillation and appropriate implantable cardioverter defibrillator therapy:: Results from a prospective study [J].
Grönefeld, GC ;
Mauss, O ;
Li, YG ;
Klingenheben, T ;
Hohnloser, SH .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (11) :1208-1214