Effect of Depression on Mortality in Implantable Cardioverter Defibrillator Recipients-Findings from the Prospective LICAD Study

被引:25
作者
Tzeis, Stylianos [2 ,3 ]
Kolb, Christof [2 ,3 ]
Baumert, Jens [4 ]
Reents, Tilko [2 ,3 ]
Zrenner, Bernhard [2 ,3 ]
Deisenhofer, Isabel [2 ,3 ]
Ronel, Joram [4 ]
Andrikopoulos, George [5 ]
Ladwig, Karl-Heinz [1 ,4 ]
机构
[1] Helmholtz Zentrum Munchen, German Res Ctr Environm Hlth, Inst Epidemiol Epi 2, D-85764 Neuherberg, Germany
[2] Deutsch Herzzentrum Munich, Munich, Germany
[3] Tech Univ Munich, Fac Med, Med Klin Klinikum Rechts Isar 1, Munich, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Fac Med, Dept Psychosomat Med & Psychotherapy, D-8000 Munich, Germany
[5] Henry Dunant Hosp, Dept Cardiol, Athens, Greece
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2011年 / 34卷 / 08期
关键词
implantable cardioverter defibrillator; depression; mortality; ACUTE MYOCARDIAL-INFARCTION; CORONARY-ARTERY-DISEASE; SUDDEN CARDIAC DEATH; HEART-FAILURE; VENTRICULAR-ARRHYTHMIAS; HOSPITAL ANXIETY; SYMPTOMS; RISK; METAANALYSIS; PREVALENCE;
D O I
10.1111/j.1540-8159.2011.03081.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Depression predicts mortality in patients with coronary artery disease and heart failure. However, its effect on patient outcome in the presence of an implantable cardioverter defibrillator (ICD) has not been investigated. Methods: A total of 236 ICD patients (76 females, 58.6 +/- 14.0 years) were screened for depressive symptoms using the Hospital Anxiety and Depression Scale (HADS). The outcome measure was all-cause mortality and the prognostic effect of depression was evaluated with Cox proportional hazards regression analysis. Results: Fifty (21%) patients reported depressive symptoms (HADS score >= 8). Renal failure (odds ratio [OR] = 4.0, 95% confidence intervals [CI] = 1.47-10.87, P = 0.007), prior angina (OR = 2.1, 95% CI = 1.07-4.12, P = 0.03), but not the experience of ICD shocks were associated with baseline depressive symptoms. In a mean follow-up period of 6.1 +/- 2.5 years, 74 patients (31%) died. Mortality significantly increased from 45.1 deaths per 1,000 person-years among patients without depression to 80.3 deaths per 1,000 person-years in patients with depressive symptoms (P = 0.039). In the univariate model, depression (HADS score = 8) was a significant predictor of mortality (OR = 1.81, 95% CI = 1.1-3.0, P = 0.02). However, in the multivariate model, depression lost its prognostic significance. Conclusions: In our prospective patient cohort, one-fifth of ICD recipients reported depressive symptoms. Depression increased the absolute mortality risk but was not an independent predictor of mortality. (PACE 2011;34:991-997)
引用
收藏
页码:991 / 997
页数:7
相关论文
共 50 条
[21]   Early mortality in prophylactic implantable cardioverter-defibrillator recipients: development and validation of a clinical risk score [J].
Kraaier, Karin ;
Scholten, Marcoen F. ;
Tijssen, Jan G. P. ;
Theuns, Dominic A. M. J. ;
Jordaens, Luc J. L. M. ;
Wilde, Arthur A. M. ;
van Dessel, Pascal F. H. M. .
EUROPACE, 2014, 16 (01) :40-46
[22]   Chronic renal insufficiency is an independent predictor of mortality in implantable cardioverter-defibrillator recipients [J].
Chen-Scarabelli, Carol ;
Scarabelli, Tiziano M. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (03) :371-376
[23]   New onset anxiety and depression in patients with an implantable cardioverter defibrillator during 24 months of follow-up (data from the national DEFIB-WOMEN study) [J].
Pedersen, Susanne S. ;
Nielsen, Jens Cosedis ;
Wehberg, Sonja ;
Jorgensen, Ole Dan ;
Riahi, Sam ;
Haarbo, Jens ;
Philbert, Berit T. ;
Larsen, Mogens Lytken ;
Johansen, Jens Brock .
GENERAL HOSPITAL PSYCHIATRY, 2021, 72 :59-65
[24]   Predicting appropriate therapies and mortality in implantable cardioverter-defibrillator recipients: a work in progress [J].
Trohman, Richard G. .
POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2019, 129 (10) :657-658
[25]   Effect of end-stage renal failure and hemodialysis on mortality rates in implantable cardioverter-defibrillator recipients [J].
Hreybe, Haitham ;
Razak, Eathar ;
Saba, Samir .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (09) :1091-1095
[26]   A prospective longitudinal study of health-related quality of life and psychological wellbeing after an implantable cardioverter-defibrillator in patients with genetic heart diseases [J].
van den Heuvel, Lieke M. ;
Sarina, Tanya ;
Sweeting, Joanna ;
Yeates, Laura ;
Bates, Kezia ;
Spinks, Catherine ;
O'Donnell, Catherine ;
Sears, Samuel F. ;
McGeechan, Kevin ;
Semsarian, Christopher ;
Ingles, Jodie .
HEART RHYTHM O2, 2022, 3 (02) :143-151
[27]   A comparison of anxiety, depression and quality of life between device shock and nonshock groups in implantable cardioverter defibrillator recipients [J].
Jacq, Fanny ;
Foulldrin, Gael ;
Savoure, Arnaud ;
Anselme, Frederic ;
Baguelin-Pinaud, Audrey ;
Cribier, Alain ;
Thibaut, Florence .
GENERAL HOSPITAL PSYCHIATRY, 2009, 31 (03) :266-273
[28]   Anger and long-term mortality and ventricular arrhythmias in patients with a first-time implantable cardioverter-defibrillator: data from the MIDAS study [J].
Pedersen, Susanne S. ;
Andersen, Christina Maar ;
Burg, Matthew ;
Theuns, Dominic A. M. J. .
EUROPACE, 2020, 22 (07) :1054-1061
[29]   Vectorcardiography Findings Are Associated with Recurrent Ventricular Arrhythmias and Mortality in Patients with Heart Failure Treated with Implantable Cardioverter-Defibrillator Device [J].
Chaudhry, Uzma ;
Cortez, Daniel ;
Platonov, Pyotr G. ;
Carlson, Jonas ;
Borgquist, Rasmus .
CARDIOLOGY, 2020, 145 (12) :784-794
[30]   The experiences of patients electrically shocked by an implantable cardioverter defibrillator: Findings from a descriptive qualitative study [J].
Palese, Alvisa ;
Cracina, Arianna ;
Purino, Michela ;
Urli, Nadia ;
Fabris, Stefano ;
Danielis, Matteo .
NURSING IN CRITICAL CARE, 2020, 25 (04) :229-237