Miniaturized biosensors employing electropolymerized permselective films and their use for creatinine assays in human serum

被引:128
作者
Madaras, MB [1 ]
Buck, RP [1 ]
机构
[1] UNIV N CAROLINA, DEPT CHEM, CHAPEL HILL, NC 27599 USA
关键词
D O I
10.1021/ac960239r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Miniaturized, disposable amperometric biosensors for determination of creatinine in human serum are described. The base electrodes are fabricated using microelectronics techniques, to build a multilayer film structure on a polyimide foil, By using a thin electropolymerized film of poly(1,3-diaminobenzene), the electrochemical interferences from ascorbate, urate, acetaminophen, and other oxidizable species are greatly diminished, The multienzyme system (creatininase, creatinase, sarcosine oxidase) is immobilized on top of the permselective layer using cross-linking of the proteins with glutaraldehyde. The electropolymerization conditions for obtaining almost ideal permselectivity of the inner layer are defined, as well as the optimal enzyme layer preparation, A composite polymeric outer membrane [Nafion + poly-(2-hydroxy-ethyl methacrylate)] is used for diffusion control and to protect the enzyme layer from fouling. The reagentless planar sensors for creatinine and creatine have fast response time (t(95) = 1 min), linear response up to 1.2 mM in batch-type and 2,0 mM in flow injection analysis and a detection limit of 10-20 mu M. They are applied in a differential setup for creatinine assay in control and hospital human serum samples and are suitable for incorporation in a portable analyzer.
引用
收藏
页码:3832 / 3839
页数:8
相关论文
共 35 条
  • [1] DEVELOPMENT OF A NEEDLE-TYPE BIOSENSOR FOR INTRAVASCULAR GLUCOSE MONITORING
    ABDELHAMID, I
    ATANASOV, P
    WILKINS, E
    [J]. ANALYTICA CHIMICA ACTA, 1995, 313 (1-2) : 45 - 54
  • [2] AMBROSE RT, 1983, CLIN CHEM, V29, P256
  • [3] BLUM W, 1949, PRINCIPLES ELECTROPL, P383
  • [4] MICROFABRICATED SENSOR ARRAYS SENSITIVE TO PH AND K+ FOR IONIC DISTRIBUTION MEASUREMENTS IN THE BEATING HEART
    COSOFRET, VV
    ERDOSY, M
    JOHNSON, TA
    BUCK, RP
    ASH, RB
    NEUMAN, MR
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (10) : 1647 - 1653
  • [5] CSOREGI E, 1995, ANAL CHEM, V67, P1240
  • [6] SIMULTANEOUS DETERMINATION OF ALLANTOIN AND CREATININE IN URINE BY A RAPID REVERSED-PHASE LIQUID-CHROMATOGRAPHIC METHOD
    DIEZ, MT
    ARIN, MJ
    RESINES, JA
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (08): : 1337 - 1350
  • [7] USE OF POLYMER-FILMS IN AMPEROMETRIC BIOSENSORS
    EMR, SA
    YACYNYCH, AM
    [J]. ELECTROANALYSIS, 1995, 7 (10) : 913 - 923
  • [8] FOSSATI P, 1983, CLIN CHEM, V29, P1494
  • [9] ELECTROPOLYMERIZED FILMS TO PREVENT INTERFERENCES AND ELECTRODE FOULING IN BIOSENSORS
    GEISE, RJ
    ADAMS, JM
    BARONE, NJ
    YACYNYCH, AM
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (02) : 151 - 160
  • [10] ELECTROPOLYMERIZED 1,3-DIAMINOBENZENE FOR THE CONSTRUCTION OF A 1,1'-DIMETHYLFERROCENE MEDIATED GLUCOSE BIOSENSOR
    GEISE, RJ
    RAO, SY
    YACYNYCH, AM
    [J]. ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 467 - 473