Dynamic effects of positive-pressure ventilation on canine left ventricular pressure-volume relations

被引:36
|
作者
Denault, AY [1 ]
Gorcsan, J [1 ]
Pinsky, MR [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Dept Anesthesiol & Crit Care Med, Div Crit Care Med,Cardiopulm Res Lab, Pittsburgh, PA 15261 USA
关键词
afterload; canine model; heart-lung interactions; mechanical ventilation; preload; ventricular function;
D O I
10.1152/jappl.2001.91.1.298
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Positive-pressure ventilation (PPV) may affect left ventricular (LV) performance by altering both LV diastolic compliance and pericardial pressure (Ppc). We measured the effect of PPV on LV intraluminal pressure, Ppc, LV volume, and LV cross-sectional area in 17 acute anesthetized dogs. To account for changes in lung volume independent of changes in Ppc and differences in contractility, measures were made during both open- and closed-chest conditions, during closed chest with and without chest wall binding, and after propranolol-induced acute ventricular failure (AVF). Apneic end-systolic pressure-volume relations (ESPVR) were generated by inferior vena caval occlusions. With the open chest, PPV had no effects. With the chest closed, PPV inspiration decreased LV end-diastolic volume (EDV) along its diastolic compliance curve and decreased end-systolic volume (ESV) such that the end-systolic pressure-volume domain was shifted to a point left of the LV ESPVR, even when referenced to Ppc. The decrease in EDV was greater in control than in AVF conditions, whereas the shift of the ESV to the left of the ESPVR was greater with AVF than in control conditions. We conclude that the hemodynamic effects of PPV inspiration are due primarily to changes in intrathoracic pressure and that the inspiration-induced decreases of LV EDV reflect direct effects of intrathoracic pressure on LV filling. The decreases in LV ESV exceed the amount explained solely by a reduction in LV ejection pressure.
引用
收藏
页码:298 / 308
页数:11
相关论文
共 50 条
  • [21] The cardiovascular effects of positive pressure ventilation
    Corp, A.
    Thomas, C.
    Adlam, M.
    BJA EDUCATION, 2021, 21 (06) : 202 - 209
  • [22] Measurement of pressure-volume curves in patients on mechanical ventilation: methods and significance
    Qin Lu
    Jean-Jacques Rouby
    Critical Care, 4
  • [23] INFLUENCE OF FILLING ON LEFT-VENTRICULAR DIASTOLIC PRESSURE-VOLUME CURVE DURING PACING ISCHEMIA IN DOGS
    SHINTANI, H
    GLANTZ, SA
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (04): : H1373 - H1385
  • [24] Noninvasive positive-pressure ventilation as a weaning strategy for intubated adults with respiratory failure
    Burns, Karen E. A.
    Meade, Maureen O.
    Premji, Azra
    Adhikari, Neill K. J.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (12):
  • [25] Indications and outcome associated with positive-pressure ventilation in dogs and cats: 127 cases
    Cagle, Laura A.
    Hopper, Kate
    Epstein, Steven E.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2022, 32 (03) : 365 - 375
  • [26] MAGNETIC-RESONANCE-IMAGING ANALYSIS OF LEFT-VENTRICULAR PRESSURE-VOLUME RELATIONS - VALIDATION WITH THE CONDUCTANCE METHOD AT REST AND DURING DOBUTAMINE STRESS
    PATTYNAMA, PMT
    DEROOS, A
    VANDERVELDE, ET
    LAMB, HJ
    STEENDIJK, P
    HERMANS, J
    BAAN, J
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (05) : 728 - 737
  • [27] Dynamic elastic pressure-volume loops in healthy pigs recorded with inspiratory and expiratory sinusoidal flow modulationRelationship to static pressure-volume loops
    Ulrika Bitzén
    Björn Drefeldt
    Lisbet Niklason
    Björn Jonson
    Intensive Care Medicine, 2004, 30 : 481 - 488
  • [28] Preload changes by positive pressure ventilation can be used for assessment of left ventricular systolic function
    Sellgren, J
    Söderström, S
    Johansson, G
    Biber, B
    Häggmark, S
    Pontén, J
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2003, 47 (05) : 541 - 548
  • [29] Application of continuous positive airway pressure to trace static pressure-volume curves of the respiratory system
    Albaiceta, GM
    Piacentini, E
    Villagrá, A
    Lopez-Aguilar, J
    Taboada, F
    Blanch, L
    CRITICAL CARE MEDICINE, 2003, 31 (10) : 2514 - 2519
  • [30] In Vivo Evaluation of a Physiologic Control System for Rotary Blood Pumps Based on the Left Ventricular Pressure-Volume Loop
    Cysyk, Joshua
    Jhun, Choon-Sik
    Newswanger, Ray
    Pae, Walter
    Izer, Jenelle
    Flory, Heidi
    Reibson, John
    Weiss, William
    Rosenberg, Gerson