Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT

被引:48
作者
Bauer, Ralf W. [1 ]
Kramer, Sebastian [1 ]
Renker, Matthias [1 ]
Schell, Boris [1 ]
Larson, Maya Christina [1 ]
Beeres, Martin [1 ]
Lehnert, Thomas [1 ]
Jacobi, Volkmar [1 ]
Vogl, Thomas J. [1 ]
Kerl, Josef Matthias [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
Dual-energy CT; 64-slice CT; Pulmonary embolism; Dose; Image quality; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ACUTE CORONARY SYNDROME; RADIATION-EXPOSURE; LUNG PERFUSION; EMBOLISM; DIAGNOSIS; FEASIBILITY; MANAGEMENT; SETTINGS; SOCIETY;
D O I
10.1007/s00330-011-2162-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To compare dose and image quality of 64-slice, first and second generation dual-energy CT (DECT) for CT pulmonary angiography (CTPA). Methods Totally 120 patients, 30 in each group, underwent CTPA on a first generation (group 1: single-energy, 120 kV/145 mAs; group 2: DE, 140/80 kV, 70/350 mAs) or second generation dual-source DECT device (group 3: DE, 100/Sn140 kV, 120/102 mAs; group 4: DE, 80/Sn140 kV, 202/86 mAs). CTDIvol, DLP, background noise (BN), thorax diameter and attenuation in the pulmonary trunk were compared. Results Thorax diameter and attenuation in the pulmonary trunk did not differ significantly (p > 0.4 and > 0.19) between the groups. Mean CTDIvol and DLP were significantly lower (p < 0.003) in group 4 (6.2 +/- 1.6 mGy/170 +/- 41 mGycm) compared to group 1 (8.5 +/- 2.6 mGy/235 +/- 117 mGycm), group 2 (9.2 +/- 3.3 mGy/224 +/- 122 mGycm) and group 3 (8.7 +/- 2.8 mGy/246 +/- 86 mGycm). BN was significantly lower (p < 0.0001) in group 4 (12 +/- 3 HU) and group 1 (13 +/- 6 HU) compared to group 3 and 2 (16 +/- 6 HU and 23 +/- 9). Conclusion The use of second generation DECT in 80/Sn140 kV configuration allows for significant dose reduction with image quality similar to 120 kV CTPA.
引用
收藏
页码:2139 / 2147
页数:9
相关论文
共 50 条
  • [31] Dose levels at coronary CT angiography—a comparison of Dual Energy-, Dual Source- and 16-slice CT
    J. Matthias Kerl
    Ralf W. Bauer
    Tobias B. Maurer
    Rene Aschenbach
    Huedayi Korkusuz
    Thomas Lehnert
    Simon Deseive
    Hanns Ackermann
    Thomas J. Vogl
    European Radiology, 2011, 21 : 530 - 537
  • [32] Prospectively gated axial CT coronary angiography: comparison of image quality and effective radiation dose between 64-and 256-slice CT
    Klass, Oliver
    Walker, Matthew
    Siebach, Anne
    Stuber, Tina
    Feuerlein, Sebastian
    Juchems, Markus
    Hoffmann, Martin H. K.
    EUROPEAN RADIOLOGY, 2010, 20 (05) : 1124 - 1131
  • [33] Effects of electrocardiogram gating on CT pulmonary angiography image quality
    Ardley, Nicholas D.
    Lau, Ken K.
    Buchan, Kevin
    Paul, Eldho
    Troupis, John M.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2014, 58 (03) : 303 - 311
  • [34] Prospectively gated axial CT coronary angiography: comparison of image quality and effective radiation dose between 64- and 256-slice CT
    Oliver Klass
    Matthew Walker
    Anne Siebach
    Tina Stuber
    Sebastian Feuerlein
    Markus Juchems
    Martin H. K. Hoffmann
    European Radiology, 2010, 20 : 1124 - 1131
  • [35] Pulmonary nodule enhancement in subtraction CT and dual-energy CT: A comparison study
    Grob, Dagmar
    Oostveen, Luuk J.
    Jacobs, Colin
    Scholten, Ernst
    Prokop, Mathias
    Schaefer-Prokop, Cornelia M.
    Sechopoulos, Ioannis
    Brink, Monique
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 134
  • [36] Dual-energy CT angiography in suspected pulmonary embolism: influence of injection protocols on image quality and perfused blood volume
    Aleksander Kosmala
    Philipp Gruschwitz
    Simon Veldhoen
    Andreas Max Weng
    Bernhard Krauss
    Thorsten Alexander Bley
    Bernhard Petritsch
    The International Journal of Cardiovascular Imaging, 2020, 36 : 2051 - 2059
  • [37] Low-Contrast Agent Dose Dual-Energy CT Monochromatic Imaging in Pulmonary Angiography Versus Routine CT
    Dong, Jian
    Wang, Xiaoying
    Jiang, Xuexiang
    Gao, Li
    Li, Feiyu
    Qiu, Jianxing
    Xu, Yufeng
    Wang, He
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 618 - 625
  • [38] Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography
    Meier, A.
    Wurnig, M.
    Desbiolles, L.
    Leschka, S.
    Frauenfelder, T.
    Alkadhi, H.
    CLINICAL RADIOLOGY, 2015, 70 (11) : 1244 - 1251
  • [39] Effectiveness of Adaptive Statistical Iterative Reconstruction for 64-Slice Dual-Energy Computed Tomography Pulmonary Angiography in Patients With a Reduced Iodine Load: Comparison With Standard Computed Tomography Pulmonary Angiography
    Lee, Ji Won
    Lee, Geewon
    Lee, Nam Kyung
    Moon, Jin Il
    Ju, Yun Hye
    Suh, Young Ju
    Jeong, Yeon Joo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (05) : 777 - 783
  • [40] Detection of Low Blood Hemoglobin Levels on Pulmonary CT Angiography: A Feasibility Study Combining Dual-Energy CT and Machine Learning
    Kay, Fernando U.
    Lumby, Cynthia
    Tanabe, Yuki
    Abbara, Suhny
    Rajiah, Prabhakar
    TOMOGRAPHY, 2023, 9 (04) : 1538 - 1550