Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT

被引:51
作者
Bauer, Ralf W. [1 ]
Kramer, Sebastian [1 ]
Renker, Matthias [1 ]
Schell, Boris [1 ]
Larson, Maya Christina [1 ]
Beeres, Martin [1 ]
Lehnert, Thomas [1 ]
Jacobi, Volkmar [1 ]
Vogl, Thomas J. [1 ]
Kerl, Josef Matthias [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
Dual-energy CT; 64-slice CT; Pulmonary embolism; Dose; Image quality; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ACUTE CORONARY SYNDROME; RADIATION-EXPOSURE; LUNG PERFUSION; EMBOLISM; DIAGNOSIS; FEASIBILITY; MANAGEMENT; SETTINGS; SOCIETY;
D O I
10.1007/s00330-011-2162-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To compare dose and image quality of 64-slice, first and second generation dual-energy CT (DECT) for CT pulmonary angiography (CTPA). Methods Totally 120 patients, 30 in each group, underwent CTPA on a first generation (group 1: single-energy, 120 kV/145 mAs; group 2: DE, 140/80 kV, 70/350 mAs) or second generation dual-source DECT device (group 3: DE, 100/Sn140 kV, 120/102 mAs; group 4: DE, 80/Sn140 kV, 202/86 mAs). CTDIvol, DLP, background noise (BN), thorax diameter and attenuation in the pulmonary trunk were compared. Results Thorax diameter and attenuation in the pulmonary trunk did not differ significantly (p > 0.4 and > 0.19) between the groups. Mean CTDIvol and DLP were significantly lower (p < 0.003) in group 4 (6.2 +/- 1.6 mGy/170 +/- 41 mGycm) compared to group 1 (8.5 +/- 2.6 mGy/235 +/- 117 mGycm), group 2 (9.2 +/- 3.3 mGy/224 +/- 122 mGycm) and group 3 (8.7 +/- 2.8 mGy/246 +/- 86 mGycm). BN was significantly lower (p < 0.0001) in group 4 (12 +/- 3 HU) and group 1 (13 +/- 6 HU) compared to group 3 and 2 (16 +/- 6 HU and 23 +/- 9). Conclusion The use of second generation DECT in 80/Sn140 kV configuration allows for significant dose reduction with image quality similar to 120 kV CTPA.
引用
收藏
页码:2139 / 2147
页数:9
相关论文
共 37 条
[11]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[12]   Reduced-dose CT: Effect on reader evaluation in detection of pulmonary embolism [J].
MacKenzie, John D. ;
Nazario-Larrieu, Javier ;
Cai, Tianxi ;
Ledbetter, M. Stephen ;
Duran-Mendicuti, Maria Alejandra ;
Judy, Philip F. ;
Rybicki, Frank J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) :1371-1379
[13]  
Mettler Fred A. Jr., 2000, Journal of Radiological Protection, V20, P353, DOI 10.1088/0952-4746/20/4/301
[14]   Prognostic significance of early diagnosis in acute pulmonary thromboembolism with circulatory failure [J].
Ota, M ;
Nakamura, M ;
Yamada, N ;
Yazu, T ;
Ishikura, K ;
Hiraoka, N ;
Tanaka, H ;
Fujioka, H ;
Isaka, N .
HEART AND VESSELS, 2002, 17 (01) :7-11
[15]   Assessment of lobar perfusion in smokers according to the presence and severity of emphysema: preliminary experience with dual-energy CT angiography [J].
Pansini, Vittorio ;
Remy-Jardin, Martine ;
Faivre, Jean-Baptiste ;
Schmidt, Bernhard ;
Dejardin-Bothelo, Alexis ;
Perez, Thierry ;
Delannoy, Valerie ;
Duhamel, Alain ;
Remy, Jacques .
EUROPEAN RADIOLOGY, 2009, 19 (12) :2834-2843
[16]   Technical principles of dual source CT [J].
Petersilka, Martin ;
Bruder, Herbert ;
Krauss, Bernhard ;
Stierstorfer, Karl ;
Flohr, Thomas G. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) :362-368
[17]   Lung Perfusion with Dual-Energy Multi-detector Row CT Can It Help Recognize Ground Glass Opacities of Vascular Origin? [J].
Pontana, Francois ;
Remy-Jardin, Martine ;
Duhamel, Alain ;
Faivre, Jean-Baptiste ;
Wallaert, Benoit ;
Remy, Jacques .
ACADEMIC RADIOLOGY, 2010, 17 (05) :587-594
[18]   Lung Perfusion with Dual-energy Multidetector-row CT (MDCT): Feasibility for the Evaluation of Acute Pulmonary Embolism in 117 Consecutive Patients [J].
Pontana, Francois ;
Faivre, Jean-Baptiste ;
Remy-Jardin, Martine ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Tacelli, Nunzia ;
Pansini, Vittorio ;
Remy, Jacques .
ACADEMIC RADIOLOGY, 2008, 15 (12) :1494-1504
[19]   Clinical validity of a negative computed tomography scan in patients with suspected pulmonary embolism - A systematic review [J].
Quiroz, R ;
Kucher, N ;
Zou, KH ;
Kipfmueller, F ;
Costello, P ;
Goldhaber, SZ ;
Schoepf, UJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (16) :2012-2017
[20]   Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society [J].
Remy-Jardin, Martine ;
Pistolesi, Massimo ;
Goodman, Lawrence R. ;
Gefter, Warren B. ;
Gottschalk, Alexander ;
Mayo, John R. ;
Sostman, H. Dirk .
RADIOLOGY, 2007, 245 (02) :315-329