Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT

被引:48
|
作者
Bauer, Ralf W. [1 ]
Kramer, Sebastian [1 ]
Renker, Matthias [1 ]
Schell, Boris [1 ]
Larson, Maya Christina [1 ]
Beeres, Martin [1 ]
Lehnert, Thomas [1 ]
Jacobi, Volkmar [1 ]
Vogl, Thomas J. [1 ]
Kerl, Josef Matthias [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
Dual-energy CT; 64-slice CT; Pulmonary embolism; Dose; Image quality; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ACUTE CORONARY SYNDROME; RADIATION-EXPOSURE; LUNG PERFUSION; EMBOLISM; DIAGNOSIS; FEASIBILITY; MANAGEMENT; SETTINGS; SOCIETY;
D O I
10.1007/s00330-011-2162-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To compare dose and image quality of 64-slice, first and second generation dual-energy CT (DECT) for CT pulmonary angiography (CTPA). Methods Totally 120 patients, 30 in each group, underwent CTPA on a first generation (group 1: single-energy, 120 kV/145 mAs; group 2: DE, 140/80 kV, 70/350 mAs) or second generation dual-source DECT device (group 3: DE, 100/Sn140 kV, 120/102 mAs; group 4: DE, 80/Sn140 kV, 202/86 mAs). CTDIvol, DLP, background noise (BN), thorax diameter and attenuation in the pulmonary trunk were compared. Results Thorax diameter and attenuation in the pulmonary trunk did not differ significantly (p > 0.4 and > 0.19) between the groups. Mean CTDIvol and DLP were significantly lower (p < 0.003) in group 4 (6.2 +/- 1.6 mGy/170 +/- 41 mGycm) compared to group 1 (8.5 +/- 2.6 mGy/235 +/- 117 mGycm), group 2 (9.2 +/- 3.3 mGy/224 +/- 122 mGycm) and group 3 (8.7 +/- 2.8 mGy/246 +/- 86 mGycm). BN was significantly lower (p < 0.0001) in group 4 (12 +/- 3 HU) and group 1 (13 +/- 6 HU) compared to group 3 and 2 (16 +/- 6 HU and 23 +/- 9). Conclusion The use of second generation DECT in 80/Sn140 kV configuration allows for significant dose reduction with image quality similar to 120 kV CTPA.
引用
收藏
页码:2139 / 2147
页数:9
相关论文
共 50 条
  • [1] Dose and image quality at CT pulmonary angiography—comparison of first and second generation dual-energy CT and 64-slice CT
    Ralf W. Bauer
    Sebastian Kramer
    Matthias Renker
    Boris Schell
    Maya Christina Larson
    Martin Beeres
    Thomas Lehnert
    Volkmar Jacobi
    Thomas J. Vogl
    Josef Matthias Kerl
    European Radiology, 2011, 21 : 2139 - 2147
  • [2] Single- and dual-energy CT pulmonary angiography using second- and third-generation dual-source CT systems: comparison of radiation dose and image quality
    Lenga, Lukas
    Trapp, Franziska
    Albrecht, Moritz H.
    Wichmann, Julian L.
    Johnson, Addison A.
    Yel, Ibrahim
    D'Angelo, Tommaso
    Booz, Christian
    Vogl, Thomas J.
    Martin, Simon S.
    EUROPEAN RADIOLOGY, 2019, 29 (09) : 4603 - 4612
  • [3] Image Quality of Low-Energy Pulmonary CT Angiography: Comparison With Standard CT
    Bogot, Naama R.
    Fingerle, Alexander
    Shaham, Dorith
    Nissenbaum, Izhak
    Sosna, Jacob
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : W273 - W278
  • [4] Single- and dual-energy CT pulmonary angiography using second- and third-generation dual-source CT systems: comparison of radiation dose and image quality
    Lukas Lenga
    Franziska Trapp
    Moritz H. Albrecht
    Julian L. Wichmann
    Addison A. Johnson
    Ibrahim Yel
    Tommaso D’Angelo
    Christian Booz
    Thomas J. Vogl
    Simon S. Martin
    European Radiology, 2019, 29 : 4603 - 4612
  • [5] Image Quality of Iodine Maps for Pulmonary Embolism: A Comparison of Subtraction CT and Dual-Energy CT
    Grob, Dagmar
    Smit, Ewoud
    Oostveen, Luuk J.
    Snoeren, Miranda M.
    Prokop, Mathias
    Schaefer-Prokop, Cornelia M.
    Sechopoulos, Ioannis
    Brink, Monique
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (06) : 1253 - 1259
  • [6] Diagnosis of Pulmonary Artery Embolism: Comparison of Single-Source CT and 3rd Generation Dual-Source CT using a Dual-Energy Protocol Regarding Image Quality and Radiation Dose
    Petritsch, Bernhard
    Kosmala, Aleksander
    Gassenmaier, Tobias
    Weng, Andreas Max
    Veldhoen, Simon
    Kunz, Andreas Steven
    Bley, Thorsten Alexander
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2017, 189 (06): : 527 - 536
  • [7] Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT
    De Zordo, Tobias
    von Lutterotti, Klemens
    Dejaco, Christian
    Soegner, Peter F.
    Frank, Renate
    Aigner, Friedrich
    Klauser, Andrea S.
    Pechlaner, Christoph
    Schoepf, U. Joseph
    Jaschke, Werner R.
    Feuchtner, Gudrun M.
    EUROPEAN RADIOLOGY, 2012, 22 (02) : 279 - 286
  • [8] Optimisation of contrast medium volume and injection-related factors in CT pulmonary angiography: 64-slice CT study
    Ramadan, Selma Uysal
    Kosar, Pinar
    Sonmez, Iclal
    Karahan, Sevilay
    Kosar, Ugur
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2100 - 2107
  • [9] Dual-energy CT angiography in suspected pulmonary embolism: influence of injection protocols on image quality and perfused blood volume
    Kosmala, Aleksander
    Gruschwitz, Philipp
    Veldhoen, Simon
    Weng, Andreas Max
    Krauss, Bernhard
    Bley, Thorsten Alexander
    Petritsch, Bernhard
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (10): : 2051 - 2059
  • [10] Dosimetric and image quality comparison of different 64-slice CT scanners
    Colli, V.
    Strocchi, S.
    Vite, C.
    Cacciatori, M.
    Rizzi, E.
    Marzoli, L.
    Conte, L.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 197 - 200