Variability of Tear Osmolarity in Patients With Dry Eye

被引:66
作者
Bunya, Vatinee Y. [1 ]
Fuerst, Nicole M. [1 ]
Pistilli, Maxwell [1 ]
McCabe, Bridgette E. [1 ]
Salvo, Rebecca [1 ]
Macchi, Ilaria [2 ]
Ying, Gui-Shuang [1 ]
Massaro-Giordano, Mina [1 ]
机构
[1] Univ Penn, Scheie Eye Inst, Dept Ophthalmol, Philadelphia, PA 19104 USA
[2] Campus Biomed Univ, Rome, Italy
关键词
CLASSIFICATION CRITERIA; SJOGRENS-SYNDROME; HYPEROSMOLARITY; FILM; TESTS;
D O I
10.1001/jamaophthalmol.2015.0429
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
IMPORTANCE Knowledge about the variability of measurements using the TearLab Osmolarity System is necessary when evaluating the clinical utility of readings. OBJECTIVE To examine the variability of tear osmolarity measured by the TearLab Osmolarity System in patients with Sjogren syndrome (SS), patients with blepharitis, and control participants. DESIGN, SETTING, AND PARTICIPANTS Cross-sectional study at a tertiary care academic center from June 13, 2012, to March 21, 2013. Participants included 74 eyes of 37 patients from a volunteer sample (18 patients with SS, 11 patients with blepharitis, and 8 control participants) who were evaluated using the TearLab Osmolarity System, with 3 consecutive osmolarity measurements taken at 1-minute intervals in a session; 15 of these patients had the same measurements taken by the same examiner in 2 additional sessions on the same day (9 AM-10 AM, 12 PM-1 PM, or 3 PM-4 PM). Most patients with SS and patients with blepharitis were taking systemic or topical dry eye medications at the time of enrollment. MAIN OUTCOMES AND MEASURES Mean osmolarity and its variability calculated from a linear mixed model for each disease group that accounts for the variations attributable to different patients, eyes, and sessions and measurement error specific to each disease group. RESULTS Mean tear osmolarity was 307mOsm/L, 304mOsm/L, and 301mOsm/L in the SS, blepharitis, and control groups, respectively (P = .46). The error associated with repeated measurements within a session in the patients without dry eye (10.5mOsm/L [95% CI, 9.0-12.4]) was significantly lower than in the patients with blepharitis (14.6mOsm/L [95% CI, 12.5-17.5]; P = .006) and patients with SS (15.8mOsm/L [95% CI, 14.2-17.8]; P < .001) but a difference in the error of repeated measurements between patients with blepharitis and patients with SS was not identified (P = .46). CONCLUSIONS AND RELEVANCE There was increased variability attributable to error in repeated measurements in patients with SS and patients with blepharitis compared with control participants. The high variability of TearLab osmolarity readings in all groups makes the clinical interpretation of measurements unclear.
引用
收藏
页码:662 / 667
页数:6
相关论文
共 29 条
[1]  
Amparo F, 2014, AM J OPHTHALMOL, V157, pe2
[2]   What is the Value of Incorporating Tear Osmolarity Measurement in Assessing Patient Response to Therapy in Dry Eye Disease? [J].
Amparo, Francisco ;
Jin, Yiping ;
Hamrah, Pedram ;
Schaumberg, Debra A. ;
Dana, Reza .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (01) :69-77
[3]  
[Anonymous], 2012, TEARLAB OSM SYST US
[4]   Tear osmolarity measurement using the TearLab™ Osmolarity System in the assessment of dry eye treatment effectiveness [J].
Benelli, Umberto ;
Nardi, Marco ;
Posarelli, Chiara ;
Albert, Timothy G. .
CONTACT LENS & ANTERIOR EYE, 2010, 33 (02) :61-67
[5]  
Bron AJ, 2007, OCUL SURF, V5, P108
[6]   Predicted Phenotypes of Dry Eye: Proposed Consequences of Its Natural History [J].
Bron, Anthony J. ;
Yokoi, Norihiko ;
Gaffney, Eamonn ;
Tiffany, John M. .
OCULAR SURFACE, 2009, 7 (02) :78-92
[7]   Reproducibility and repeatability of the OcuSense TearLab™ osmometer [J].
Eperjesi, Frank ;
Aujla, Maana ;
Bartlett, Hannah .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (08) :1201-1205
[8]  
FARRIS RL, 1994, ADV EXP MED BIOL, V350, P495
[9]   HUMAN TEAR FILM ELECTROLYTE CONCENTRATIONS IN HEALTH AND DRY-EYE DISEASE [J].
GILBARD, JP .
INTERNATIONAL OPHTHALMOLOGY CLINICS, 1994, 34 (01) :27-36
[10]  
Gipson IK, 2007, OCUL SURF, V5, P179