Tube Current Modulation Between Single- and Dual-Energy CT With a Second-Generation Dual-Source Scanner: Radiation Dose and Image Quality

被引:7
作者
Matsubara, Kosuke [1 ]
Takata, Tadanori [2 ]
Kobayashi, Masanao [3 ]
Kobayashi, Satoshi [1 ]
Koshida, Kichiro [1 ]
Gabata, Toshifumi [4 ]
机构
[1] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ Hosp, Dept Radiol Technol, Kanazawa, Ishikawa, Japan
[3] Fujita Hlth Univ, Sch Hlth Sci, Fac Radiol Technol, Toyoake, Aichi, Japan
[4] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Dept Radiol, Fac Med, Kanazawa, Ishikawa, Japan
关键词
dosimetry; dual-energy CT; image noise; radiation dose; tube current modulation; AUTOMATIC EXPOSURE CONTROL; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; PATIENT SIZE; ABDOMINAL CT; ITERATIVE RECONSTRUCTION; STONE COMPOSITION; BLOOD-VOLUME; ANGIOGRAPHY; REDUCTION;
D O I
10.2214/AJR.15.15404
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare the effects of tube current modulation between single- and dual-energy CT with a second-generation dual-source scanner. MATERIALS AND METHODS. Custom-made elliptic polymethylmethacrylate phantoms for slim and large patients were used. Absorbed radiation dose at the central point of the phantoms was measured with a solid-state detector while the phantoms were scanned in single-energy (120 kV) and dual-energy (100/Sn140, 80/Sn140, and 140/80 kV) modes with a second-generation dual-source CT scanner. Tube current modulation was activated in both modes, and quality reference tube current-time settings of 150, 300, 450, and 600 mAs were selected. Scanning was performed three times under the same conditions, and image noise was evaluated by measuring the SD of CT numbers in four separate regions of three adjacent images of the phantoms. RESULTS. Absorbed dose increased and image noise decreased with an increase in quality reference tube current-time setting when the slim phantom was scanned. For the large phantom, the radiation dose and noise level reached a plateau above quality reference tube current-time settings of 300 mAs for 100/Sn140 kV and 450 mAs for 120 kV. The radiation dose was small and the noise level was large with 80/Sn140 kV compared with that obtained with 120 and 100/Sn140 kV at all quality reference tube current-time settings. CONCLUSION. When a large phantom is scanned with 100/Sn140 kV, exposure demand for tube current modulation exceeds system limits at a lower quality reference tube current-time setting than for scanning 120 kV.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 50 条
  • [41] Radiation dose and image quality of computed tomography of the supra-aortic arteries: A comparison between single-source and dual-source CT Scanners
    Saba, Luca
    di Martino, Michele
    Siotto, Paolo
    Anzidei, Michele
    Argiolas, Giovanni Maria
    Porcu, Michele
    Suri, Jasjit S.
    Wintermark, Max
    JOURNAL OF NEURORADIOLOGY, 2018, 45 (02) : 136 - 141
  • [42] Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT
    Park, Clara
    Gruber-Rouh, Tatjana
    Leithner, Doris
    Zierden, Amelie
    Albrecht, Mortiz H.
    Wichmann, Julian L.
    Bodelle, Boris
    Elsabaie, Mohamed
    Scholtz, Jan-Erik
    Kaup, Moritz
    Vogl, Thomas J.
    Beeres, Martin
    CANCER IMAGING, 2016, 16 : 1 - 7
  • [43] Feasibility of Dose Optimization in a Second-Generation Dual-Source CT Scanner for a Manufacturer-Recommended Urolithiasis Protocol for Imaging Renal Stones
    Pansini, Michele
    Morsbach, Fabian
    Schubert, Tilman
    Hohmann, Joachim
    Kovacs, Balazs
    Szucs-Farkas, Zsolt
    Schindera, Sebastian T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (02) : 348 - 354
  • [44] Automated Tube Voltage Selection in Thoracoabdominal Computed Tomography at High Pitch Using a Third-Generation Dual-Source Scanner Image Quality and Radiation Dose Performance
    Lurz, Markus
    Lell, Michael M.
    Wuest, Wolfgang
    Eller, Achim
    Scharf, Michael
    Uder, Michael
    May, Matthias Stefan
    INVESTIGATIVE RADIOLOGY, 2015, 50 (05) : 352 - 360
  • [45] Simulated Radiation Dose Reduction in Whole-Body CT on a 3rd Generation Dual-Source Scanner: An Intraindividual Comparison
    Brendlin, Andreas S.
    Winkelmann, Moritz T.
    Do, Phuong Linh
    Schwarze, Vincent
    Peisen, Felix
    Almansour, Haidara
    Bongers, Malte N.
    Artzner, Christoph P.
    Weiss, Jakob
    Kim, Jong Hyo
    Othman, Ahmed E.
    Afat, Saif
    DIAGNOSTICS, 2021, 11 (01)
  • [46] Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study
    Meinel, Felix G.
    Canstein, Christian
    Schoepf, U. Joseph
    Sedlmaier, Martin
    Schmidt, Bernhard
    Harris, Brett S.
    Flohr, Thomas G.
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2014, 24 (07) : 1643 - 1650
  • [47] The effect of tube voltage combination on image artefact and radiation dose in dual-source dual-energy CT: comparison between conventional 80/140 kV and 80/150 kV plus tin filter for gout protocol
    Jeon, Ji Young
    Lee, Sheen-Woo
    Jeong, Yu Mi
    Baek, Han Joo
    EUROPEAN RADIOLOGY, 2019, 29 (03) : 1248 - 1257
  • [48] Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction
    De Cecco, Carlo N.
    Muscogiuri, Giuseppe
    Schoepf, U. Joseph
    Caruso, Damiano
    Wichmann, Julian L.
    Cannao, Paola M.
    Canstein, Christian
    Fuller, Stephen R.
    Snider, Lauren
    Varga-Szemes, Akos
    Hardie, Andrew D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (07) : 1257 - 1264
  • [49] Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT
    Euler, Andre
    Obmann, Markus M.
    Szucs-Farkas, Zsolt
    Mileto, Achille
    Zaehringer, Caroline
    Falkowski, Anna L.
    Winkel, David J.
    Marin, Daniele
    Stieltjes, Bram
    Krauss, Bernhard
    Schindera, Sebastian T.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3405 - 3412
  • [50] Image quality and dose exposure of contrast-enhanced abdominal CT on a 1st generation clinical dual-source photon-counting detector CT in obese patients vs. a 2nd generation dual-source dual energy integrating detector CT
    Hagen, Florian
    Hofmann, Johannes
    Wrazidlo, Robin
    Gutjahr, Ralf
    Schmidt, Bernhard
    Faby, Sebastian
    Nikolaou, Konstantin
    Horger, Marius
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 151