Tube Current Modulation Between Single- and Dual-Energy CT With a Second-Generation Dual-Source Scanner: Radiation Dose and Image Quality

被引:7
作者
Matsubara, Kosuke [1 ]
Takata, Tadanori [2 ]
Kobayashi, Masanao [3 ]
Kobayashi, Satoshi [1 ]
Koshida, Kichiro [1 ]
Gabata, Toshifumi [4 ]
机构
[1] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ Hosp, Dept Radiol Technol, Kanazawa, Ishikawa, Japan
[3] Fujita Hlth Univ, Sch Hlth Sci, Fac Radiol Technol, Toyoake, Aichi, Japan
[4] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Dept Radiol, Fac Med, Kanazawa, Ishikawa, Japan
关键词
dosimetry; dual-energy CT; image noise; radiation dose; tube current modulation; AUTOMATIC EXPOSURE CONTROL; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; PATIENT SIZE; ABDOMINAL CT; ITERATIVE RECONSTRUCTION; STONE COMPOSITION; BLOOD-VOLUME; ANGIOGRAPHY; REDUCTION;
D O I
10.2214/AJR.15.15404
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare the effects of tube current modulation between single- and dual-energy CT with a second-generation dual-source scanner. MATERIALS AND METHODS. Custom-made elliptic polymethylmethacrylate phantoms for slim and large patients were used. Absorbed radiation dose at the central point of the phantoms was measured with a solid-state detector while the phantoms were scanned in single-energy (120 kV) and dual-energy (100/Sn140, 80/Sn140, and 140/80 kV) modes with a second-generation dual-source CT scanner. Tube current modulation was activated in both modes, and quality reference tube current-time settings of 150, 300, 450, and 600 mAs were selected. Scanning was performed three times under the same conditions, and image noise was evaluated by measuring the SD of CT numbers in four separate regions of three adjacent images of the phantoms. RESULTS. Absorbed dose increased and image noise decreased with an increase in quality reference tube current-time setting when the slim phantom was scanned. For the large phantom, the radiation dose and noise level reached a plateau above quality reference tube current-time settings of 300 mAs for 100/Sn140 kV and 450 mAs for 120 kV. The radiation dose was small and the noise level was large with 80/Sn140 kV compared with that obtained with 120 and 100/Sn140 kV at all quality reference tube current-time settings. CONCLUSION. When a large phantom is scanned with 100/Sn140 kV, exposure demand for tube current modulation exceeds system limits at a lower quality reference tube current-time setting than for scanning 120 kV.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 50 条
  • [31] Evaluation of Image Quality and Detectability of Deep Learning Image Reconstruction (DLIR) Algorithm in Single- and Dual-energy CT
    Zhong, Jingyu
    Shen, Hailin
    Chen, Yong
    Xia, Yihan
    Shi, Xiaomeng
    Lu, Wei
    Li, Jianying
    Xing, Yue
    Hu, Yangfan
    Ge, Xiang
    Ding, Defang
    Jiang, Zhenming
    Yao, Weiwu
    JOURNAL OF DIGITAL IMAGING, 2023, 36 (04) : 1390 - 1407
  • [32] Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose
    Daniella F. Pinho
    Naveen M. Kulkarni
    Arun Krishnaraj
    Sanjeeva P. Kalva
    Dushyant V. Sahani
    European Radiology, 2013, 23 : 351 - 359
  • [33] Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability
    Solomon, Justin
    Wilson, Joshua
    Samei, Ehsan
    MEDICAL PHYSICS, 2015, 42 (08) : 4941 - 4953
  • [34] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786
  • [35] Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality
    Jeremy R. Wortman
    Jeffrey Y. Shyu
    Jeffrey Dileo
    Jennifer W. Uyeda
    Aaron D. Sodickson
    Emergency Radiology, 2020, 27 : 45 - 50
  • [36] Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality
    Wortman, Jeremy R.
    Shyu, Jeffrey Y.
    Dileo, Jeffrey
    Uyeda, Jennifer W.
    Sodickson, Aaron D.
    EMERGENCY RADIOLOGY, 2020, 27 (01) : 45 - 50
  • [37] Effects of Patient Size and Radiation Dose on Iodine Quanti fi cation in Dual-Source Dual-Energy CT
    Jiang, Xia
    Yang, Xiangyu
    Hintenlang, David E.
    White, Richard D.
    ACADEMIC RADIOLOGY, 2021, 28 (01) : 96 - 105
  • [38] Dual-Energy CT Perfusion During Pharmacologic Stress for the Assessment of Myocardial Perfusion Defects Using a Second-Generation Dual-Source CT: A Comparison With Cardiac Magnetic Resonance Imaging
    Kim, Sung Mok
    Chang, Sung-A
    Shin, Wonseon
    Choe, Yeon Hyeon
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) : 44 - 52
  • [39] Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: Image quality, radiation dose and diagnostic performance
    Sun, Hao
    Hou, Xin-Yi
    Xue, Hua-Dan
    Li, Xiao-Guang
    Jin, Zheng-Yu
    Qian, Jia-Ming
    Yu, Jian-Chun
    Zhu, Hua-Dong
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (05) : 884 - 891
  • [40] Radiation dose and image quality of computed tomography of the supra-aortic arteries: A comparison between single-source and dual-source CT Scanners
    Saba, Luca
    di Martino, Michele
    Siotto, Paolo
    Anzidei, Michele
    Argiolas, Giovanni Maria
    Porcu, Michele
    Suri, Jasjit S.
    Wintermark, Max
    JOURNAL OF NEURORADIOLOGY, 2018, 45 (02) : 136 - 141