Tube Current Modulation Between Single- and Dual-Energy CT With a Second-Generation Dual-Source Scanner: Radiation Dose and Image Quality

被引:7
作者
Matsubara, Kosuke [1 ]
Takata, Tadanori [2 ]
Kobayashi, Masanao [3 ]
Kobayashi, Satoshi [1 ]
Koshida, Kichiro [1 ]
Gabata, Toshifumi [4 ]
机构
[1] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ Hosp, Dept Radiol Technol, Kanazawa, Ishikawa, Japan
[3] Fujita Hlth Univ, Sch Hlth Sci, Fac Radiol Technol, Toyoake, Aichi, Japan
[4] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Dept Radiol, Fac Med, Kanazawa, Ishikawa, Japan
关键词
dosimetry; dual-energy CT; image noise; radiation dose; tube current modulation; AUTOMATIC EXPOSURE CONTROL; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; PATIENT SIZE; ABDOMINAL CT; ITERATIVE RECONSTRUCTION; STONE COMPOSITION; BLOOD-VOLUME; ANGIOGRAPHY; REDUCTION;
D O I
10.2214/AJR.15.15404
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare the effects of tube current modulation between single- and dual-energy CT with a second-generation dual-source scanner. MATERIALS AND METHODS. Custom-made elliptic polymethylmethacrylate phantoms for slim and large patients were used. Absorbed radiation dose at the central point of the phantoms was measured with a solid-state detector while the phantoms were scanned in single-energy (120 kV) and dual-energy (100/Sn140, 80/Sn140, and 140/80 kV) modes with a second-generation dual-source CT scanner. Tube current modulation was activated in both modes, and quality reference tube current-time settings of 150, 300, 450, and 600 mAs were selected. Scanning was performed three times under the same conditions, and image noise was evaluated by measuring the SD of CT numbers in four separate regions of three adjacent images of the phantoms. RESULTS. Absorbed dose increased and image noise decreased with an increase in quality reference tube current-time setting when the slim phantom was scanned. For the large phantom, the radiation dose and noise level reached a plateau above quality reference tube current-time settings of 300 mAs for 100/Sn140 kV and 450 mAs for 120 kV. The radiation dose was small and the noise level was large with 80/Sn140 kV compared with that obtained with 120 and 100/Sn140 kV at all quality reference tube current-time settings. CONCLUSION. When a large phantom is scanned with 100/Sn140 kV, exposure demand for tube current modulation exceeds system limits at a lower quality reference tube current-time setting than for scanning 120 kV.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 39 条
[1]   Dose to Radiosensitive Organs During Routine Chest CT: Effects of Tube Current Modulation [J].
Angel, Erin ;
Yaghmai, Nazanin ;
Jude, Cecilia Matilda ;
DeMarco, John J. ;
Cagnon, Christopher H. ;
Goldin, Jonathan G. ;
McCollough, Cynthia H. ;
Primak, Andrew N. ;
Cody, Dianna D. ;
Stevens, Donna M. ;
McNitt-Gray, Michael F. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) :1340-1345
[2]   Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT [J].
Angel, Erin ;
Yaghmai, Nazanin ;
Jude, Cecilia Matilda ;
DeMarco, John J. ;
Cagnon, Christopher H. ;
Goldin, Jonathan G. ;
Primak, Andrew N. ;
Stevens, Donna M. ;
Cody, Dianna D. ;
McCollough, Cynthia H. ;
McNitt-Gray, Michael F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (03) :497-511
[3]   Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation [J].
Bamberg, Fabian ;
Dierks, Alexander ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Becker, Christoph R. ;
Johnson, Thorsten R. C. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1424-1429
[4]   Incidental adrenal lesions detected on enhanced abdominal dual-energy CT: Can the diagnostic workup be shortened by the implementation of virtual unenhanced images? [J].
Botsikas, Diomidis ;
Triponez, Frederic ;
Boudabbous, Sana ;
Hansen, Catrina ;
Becker, Christoph D. ;
Montet, Xavier .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) :1746-1751
[5]   Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media [J].
Grant, Katharine L. ;
Flohr, Thomas G. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Thomas, Christoph ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2014, 49 (09) :586-592
[6]   Dual-energy CT angiography of abdomen with routine concentration contrast agent in comparison with conventional single-energy CT with high concentration contrast agent [J].
He, Jingzhen ;
Wang, Qing ;
Ma, Xiangxing ;
Sun, Zhiyuan .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (02) :221-227
[7]   Point dose profile measurements using solid-state detectors in characterization of Computed Tomography systems [J].
Herrnsdorf, L. ;
Bjork, M. ;
Cederquist, B. ;
Mattsson, C. G. ;
Thungstrom, G. ;
Frojdh, C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) :223-225
[8]   Dual-Energy CT Angiography for Assessment of Regional Pulmonary Perfusion in Patients With Chronic Thromboembolic Pulmonary Hypertension: Initial Experience [J].
Hoey, Edward T. D. ;
Mirsadraee, Saeed ;
Pepke-Zaba, Joanna ;
Jenkins, David P. ;
Gopalan, Deepa ;
Screaton, Nicholas J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (03) :524-532
[9]   Patient Size and Radiation Exposure in Thoracic, Pelvic, and Abdominal CT Examinations Performed With Automatic Exposure Control [J].
Israel, Gary M. ;
Cicchiello, Lawrence ;
Brink, James ;
Huda, Walter .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) :1342-1346
[10]   In Vivo Comparison of Radiation Exposure of Dual-Energy CT Versus Low-Dose CT Versus Standard CT for Imaging Urinary Calculi [J].
Jepperson, Maria A. ;
Cernigliaro, Joseph G. ;
Ibrahim, El-Sayed H. ;
Morin, Richard L. ;
Haley, William E. ;
Thiel, David D. .
JOURNAL OF ENDOUROLOGY, 2015, 29 (02) :141-146