Ocular irritation reversibility assessment for personal care products using a porcine corneal culture assay

被引:5
|
作者
Donahue, Douglas A. [1 ]
Avalos, Javier [1 ]
Kaufman, Lewis E. [2 ]
Simion, F. Anthony [1 ]
Cerven, Daniel R. [3 ]
机构
[1] Kao Brands Co, Cincinnati, OH 45214 USA
[2] Scripterra Sci, Wooster, OH USA
[3] MB Res Labs Inc, Spinnerstown, PA USA
关键词
Ocular irritation; Ocular reversibility; Porcine cornea; Alternative assay; Corneal culture; Cosmetics; EYE IRRITATION; ORGAN-CULTURE; MODEL; TOXICITY; EXPOSURE; LAYER;
D O I
10.1016/j.tiv.2010.12.008
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Personal care product manufacturers have used a broad spectrum of alternative ocular irritation assays during the past two decades because these tests do not require the use of live animals, they provide reliable predictive data, and they are relatively inexpensive to conduct. To complement these assays, the ex vivo Porcine Corneal Opacity Reversibility Assay (PorCORA) was recently developed using a corneal culture model to predict reversibility of ocular irritants. Three commercially available consumer products (a shampoo, a hair color glaze, and a hair colorant system containing 12% hydrogen peroxide) were each tested in two PorCORA study replicates in order to assess potential ocular damage reversibility for surfactant-, propylene carbonate-, and peroxide-based formulations, respectively. Under the exaggerated, in vitro study conditions, the surfactant-based shampoo may cause irreversible porcine corneal damage (histological changes in the epithelial squamous cell and/or basal cell layers), whereas the hair color glaze and 12% hydrogen peroxide product caused fully reversible ocular irritation (microscopic changes only in the superficial squamous cell layer). The hair color glaze and peroxide product results correlate with established in vivo data for similar compounds, but the shampoo results contradicted previous BCOP results (expected to be only a mild irritant). Therefore, although the PorCORA protocol shows promise in predicting the extent and reversibility of potential ocular damage caused by accidental consumer eye exposure to personal care products, the contradictory results for the surfactant-based shampoo indicate that more extensive validation testing of the PorCORA is necessary to definitively establish the protocol's reliability as a Draize test replacement. (c) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:708 / 714
页数:7
相关论文
共 50 条
  • [21] Concentration and health risk assessment of per- and polyfluoroalkyl substances in cosmetic and personal care products
    Keawmanee, Sasipin
    Piyaviriyakul, Pitchaya
    Boontanon, Narin
    Waiyarat, Sonthinee
    Sukeesan, Suratsawadee
    Kongpran, Jira
    Boontanon, Suwanna Kitpati
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2024, 59 (09) : 551 - 561
  • [22] Histopathological evaluation of the ocular-irritation potential of shampoos, make-up removers and cleansing foams in the bovine corneal opacity and permeability assay
    Furukawa, Masatoshi
    Sakakibara, Takashi
    Itoh, Kouta
    Kawamura, Kohtaro
    Sasaki, Satoshi
    Matsuura, Masao
    JOURNAL OF TOXICOLOGIC PATHOLOGY, 2015, 28 (04) : 243 - 248
  • [23] An improved human skin explant culture method for testing and assessing personal care products
    Zhou, Linli
    Ji, Wei
    Dicolandrea, Teresa
    Finlay, Deborah
    Supp, Dorothy
    Boyce, Steven
    Wei, Karl
    Kadekaro, Ana Luisa
    Zhang, Yuhang
    JOURNAL OF COSMETIC DERMATOLOGY, 2023, 22 (05) : 1585 - 1594
  • [24] Reconstituted human corneal epithelium: A new alternative to the Draize eye test for the assessment of the eye irritation potential of chemicals and cosmetic products
    Doucet, O
    Lanvin, M
    Thillou, C
    Linossier, C
    Pupat, C
    Merlin, B
    Zastrow, L
    TOXICOLOGY IN VITRO, 2006, 20 (04) : 499 - 512
  • [25] Human Cumulative Irritation Tests of Common Preservatives Used in Personal Care Products: A Retrospective Analysis of Over 45 000 Subjects
    Walters, Russel M.
    Khanna, Preeya
    Hamilton, Matthew
    Mays, David A.
    Telofski, Lorena
    TOXICOLOGICAL SCIENCES, 2015, 148 (01) : 101 - 107
  • [26] Prediction of eye irritation potential of liquid and granular laundry detergent formulas using the bovine corneal opacity and permeability (BCOP) assay
    Cater, Kathleen C.
    Harbell, John W.
    CUTANEOUS AND OCULAR TOXICOLOGY, 2013, 32 (03) : 210 - 221
  • [27] A reassessment of the in vitro RBC haemolysis assay with defibrinated sheep blood for the determination of the ocular irritation potential of cosmetic products:: Comparison with the in vivo Draize rabbit test
    Alves, Eloisa Nunes
    Presgrave, Rosaura de Farias
    Franca Presgrave, Octavio Augusto
    Sabagh, Fernanda Peres
    Rolim de Freitas, Joao Carlos Borges
    Corrado, Alexandre Pinto
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2008, 36 (03): : 275 - 284
  • [28] Safety assessment of starch-based personal care products: Nanocapsules and pickering emulsions
    Marto, J.
    Pinto, P.
    Fitas, M.
    Goncalves, L. M.
    Almeida, A. J.
    Ribeiro, H. M.
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 2018, 342 : 14 - 21
  • [29] Study of the difficulties encountered by Brazilian laboratories in implementing alternative methods to animal use: assessment of Ocular Irritation and the Bovine Corneal Opacity and Permeability (BCOP) test
    Gimenes, Izabela
    Presgrave, Octavio Augusto Franca
    Gonzalez, Marcelo Salabert
    Alves, Gutemberg Gomes
    VIGILANCIA SANITARIA EM DEBATE-SOCIEDADE CIENCIA & TECNOLOGIA, 2024, 12
  • [30] PLANARIAN MOBILITY ASSAY AS A SIMPLE ALTERNATIVE FOR RAPID SCREENING AQUATIC ACUTE TOXICITY OF PERSONAL CARE PRODUCTS
    Li, Mei-Hui
    FRESENIUS ENVIRONMENTAL BULLETIN, 2020, 29 (05): : 3362 - 3369