Suitability of eigenvalue beam-forming for discrete multi-frequency hyperthermia treatment planning

被引:2
|
作者
Zanoli, Massimiliano [1 ]
Trefna, Hana Dobsicek [1 ]
机构
[1] Chalmers Univ Technol, Dept Elect Engn, Horsalsvagen 11, S-41258 Gothenburg, Sweden
关键词
eigenvalue beam-forming; microwave hyperthermia; multi-frequency; treatment planning; PHASED-ARRAY HYPERTHERMIA; MICROWAVE HYPERTHERMIA; DEEP HYPERTHERMIA; QUALITY-ASSURANCE; OPTIMIZATION; TEMPERATURE; HEAD; RADIATION; RECURRENT; IMPACT;
D O I
10.1002/mp.15220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Thermal dose delivery in microwave hyperthermia for cancer treatment is expected to benefit from the introduction of ultra-wideband (UWB)-phased array applicators. A full exploitation of the combination of different frequencies to improve the deposition pattern is, however, a nontrivial problem. It is unclear whether the cost functions used for hyperthermia treatment planning (HTP) optimization in the single-frequency setting can be meaningfully extended to the UWB case. Method We discuss the ability of the eigenvalue (EV) and a novel implementation of iterative-EV (i-EV) beam-forming methods to fully exploit the available frequency spectrum when a discrete set of simultaneous operating frequencies is available for treatment. We show that the quadratic power deposition ratio solved by the methods can be maximized by only one frequency in the set, therefore rendering EV inadequate for UWB treatment planning. We further investigate whether this represents a limitation in two realistic test cases, comparing the thermal distributions resulting from EV and i-EV to those obtained by optimizing for other nonlinear cost functions that allow for multi-frequency. Results The classical EV-based single-frequency HTP yields systematically lower target SAR deposition and temperature values than nonlinear HTP. In a larynx target, the proposed single-frequency i-EV scheme is able to compensate for this and reach temperatures comparable to those given by global nonlinear optimization. In a meninges target, the multi-frequency setting outperforms the single-frequency one, achieving better target coverage and 0.5 circle C higher T90 in the tumor than single-frequency-based HTP. Conclusions Classical EV performs poorly in terms of resulting target temperatures. The proposed single-frequency i-EV scheme can be a viable option depending on the patient and tumor to be treated, as long as the proper operating frequency can be selected across a UWB range. Multi-frequency HTP can bring a considerable benefit in regions typically difficult to treat such as the brain.
引用
收藏
页码:7410 / 7426
页数:17
相关论文
共 19 条
  • [1] Iterative time-reversal for multi-frequency hyperthermia
    Zanoli, Massimiliano
    Trefna, Hana Dobsicek
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (04)
  • [2] A Refined Eigenvalue-Based Optimization Technique for Hyperthermia Treatment Planning
    Mestrom, R. M. C.
    van Engelen, J. P.
    van Beurden, M. C.
    Paulides, M. M.
    Numan, W. C. M.
    Tijhuis, A. G.
    2014 8TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2014, : 2010 - 2013
  • [3] Feasibility and relevance of discrete vasculature modeling in routine hyperthermia treatment planning
    Sumser, Kemal
    Neufeld, Esra
    Verhaart, Rene F.
    Fortunati, Valerio
    Verduijn, Gerda M.
    Drizdal, Tomas
    van Walsum, Theo
    Veenland, Jifke F.
    Paulides, Margarethus M.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 36 (01) : 801 - 811
  • [4] Multi-frequency compact encoding metasurface for independent beam control
    Huang, Xiaojun
    Li, Wentao
    Xue, Qi
    Gao, Junfei
    Wang, Danqi
    Xiang, Mei
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2025, 58 (10)
  • [5] Multi-frequency AOM for multi-beam laser scanning exposure system
    Shinada, Hidetoshi
    OPTICAL REVIEW, 2016, 23 (05) : 765 - 769
  • [6] Multi-frequency AOM for multi-beam laser scanning exposure system
    Hidetoshi Shinada
    Optical Review, 2016, 23 : 765 - 769
  • [7] Passive multi-frequency brain imaging and hyperthermia irradiation apparatus: the use of dielectric matching materials in phantom experiments
    Gouzouasis, Ioannis
    Karathanasis, Konstantinos
    Karanasiou, Irene
    Uzunoglu, Nikolaos
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (10)
  • [8] A Multi-Frequency Tomographic Inverse Scattering Using Beam Basis Functions
    Tuvi, Ram
    SENSORS, 2022, 22 (04)
  • [9] MULTI-STACKED AND NITROGEN DOPED GRAPHENE LAYERS FOR MICROWAVE HYPERTHERMIA TREATMENT PLANNING WITH LEAST EXPOSURE TIME
    Singla, A.
    Marwaha, A.
    Marwaha, S.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2023, 18 (04): : 1973 - 1993
  • [10] Model-Based Reconstruction for Multi-Frequency Collimated Beam Ultrasound Systems
    Alanazi, Abdulrahman M.
    Venkatakrishnan, Singanallur
    Santos-Villalobos, Hector
    Buzzard, Gregery T.
    Bouman, Charles
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2023, 9 : 904 - 916