摘要
This paper proposes a NH3/CO2 cascade refrigeration system that sets an auxiliary refrigeration loop in the high-temperature cycle to increase the subcooling degree in the low-temperature cycle (CRSS). Based on the basic principles of thermodynamics, a mathematical model is established and theoretical simulation is carried out to obtain the influence of key parameters on the cycle performance. Compared with the conventional cascade refrigeration system (CCRS), the conclusions find that there exists an optimal condensation temperature of low-temperature cycle (T-MC.opt) to maximize COP. The maximum COP of CRSS is 4.58% higher than that of CCRS when the subcooling degree is 10 degrees C. The maximum exergy efficiency is 0.391, increasing by 4.40%. With the increase of the subcooling degree, both the COP and the T-MC. opt of CRSS increase. When the subcooling degree increases from 5 degrees C to 15 degrees C, the performance increment increases from 2.73% to 6.00%. When the evaporation temperature of the system changes, both the COP and exergy efficiency decreases slightly and it is found that the performance is better when the evaporation temperature is lower when condensation temperature is kept constant. Besides, the discharge temperature of the NH3 compressor in CRSS can be reduced by 9.9 degrees C when the evaporation temperature is -30 degrees C. (c) 2022 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:1757 / 1767
页数:11
相关论文
共 36 条
[1]   Influence of internal heat exchanger position on the performance of ejector-enhanced auto-cascade refrigeration cycle for the low-temperature freezer [J].
Bai, Tao ;
Yan, Gang ;
Yu, Jianlin .
ENERGY, 2022, 238
[2]   Energetic performance of transcritical CO2 refrigeration cycles with mechanical subcooling using zeotropic mixture as refrigerant [J].
Dai, Baomin ;
Liu, Shengchun ;
Li, Hailong ;
Sun, Zhili ;
Song, Mengjie ;
Yang, Qianru ;
Ma, Yitai .
ENERGY, 2018, 150 :205-221
[3]   Thermodynamic investigation and optimization of novel ejector-expansion CO2/NH3 cascade refrigeration cycles (novel CO2/NH3 cycle) [J].
Dokandari, Damoon Aghazadeh ;
Hagh, Alireza Setayesh ;
Mahmoudi, S. M. S. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 46 :26-36
[4]   Theoretical analysis of a CO2-NH3 cascade refrigeration system for cooling applications at low temperatures [J].
Dopazo, J. Alberto ;
Fernandez-Seara, Jose ;
Sieres, Jaime ;
Uhia, Francisco J. .
APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) :1577-1583
[5]   Numerical optimization of a transcritical CO2/propylene cascaded refrigeration-heat pump system with economizer in HT cycle [J].
Dubey, Alok Manas ;
Kumar, Suresh ;
Das Agrawal, Ghanshyam .
SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2015, 40 (02) :437-454
[6]   Exergoeconomic analysis of carbon dioxide transcritical refrigeration machines [J].
Fazelpour, Farivar ;
Morosuk, Tatiana .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 38 :128-139
[7]   Performance enhancement of a subcooled cold storage air conditioning system [J].
Hsiao, Ming-Jer ;
Cheng, Chiao-Hung ;
Huang, Ming-Chao ;
Chen, Sih-Li .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (12) :2992-2998
[8]   A FEASIBILITY ANALYSIS OF REPLACING THE STANDARD AMMONIA REFRIGERATION DEVICE WITH THE CASCADE NH3/CO2 REFRIGERATION DEVICE IN THE FOOD INDUSTRY [J].
Jankovich, Dennis ;
Osman, Kresimir .
THERMAL SCIENCE, 2015, 19 (05) :1821-1833
[9]   Comparison of transcritical CO2 refrigeration cycle with expander and throttling valve including/excluding internal heat exchanger: Exergy and energy points of view [J].
Joneydi Shariatzadeh, O. ;
Abolhassani, S. S. ;
Rahmani, M. ;
Nejad, M. Ziaee .
APPLIED THERMAL ENGINEERING, 2016, 93 :779-787
[10]   Transcritical CO2 refrigeration cycle with ejector-expansion device [J].
Li, DQ ;
Groll, EA .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (05) :766-773