Investigation of perfusion in osseous vessels in close vicinity to piezo-electric bone cutting

被引:13
|
作者
von See, C. [1 ]
Gellrich, N. -C. [1 ]
Ruecker, M. [1 ]
Kokemueller, H. [1 ]
Kober, H. [2 ]
Stoever, E. [2 ]
机构
[1] Hannover Med Sch, Dept Oral & Maxillofacial Surg, Ctr Dent Oral & Orthodont Surg, D-30625 Hannover, Germany
[2] Tech Univ Hamburg, Inst Prod Management & Engn, Hamburg, Germany
来源
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY | 2012年 / 50卷 / 03期
关键词
Piezosurgery; Thrombosis; Bone; Ultrasound; Osteotomy; ROOT SURFACE; OSTEOTOMY; SURGERY; MODEL; PIEZOSURGERY((R)); ULTRASOUND; DEVICE;
D O I
10.1016/j.bjoms.2011.04.069
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Cutting bones by piezosurgery leads to failure of perfusion at the site of the osteotomy, the cause of which cannot be identified immediately. Among other things the formation of vascular thrombi by the transmission of oscillations from the piezoelectric unit to the bone may be responsible. We used three output levels of oscillation that were predefined by the system. The outer cortical bone of the calvaria of rats (n = 24) was removed horizontally and the intraosseous vessels exposed at the surface of the osteotomy. The blood flow was then examined repeatedly using intravital fluorescence microscopy. To calculate the transmission of oscillations to the bone, the spatial oscillation frequency of each calvarium and the contact pressure during removal of bone in vitro (n = 18) were also examined. After removal of the bone there was constant blood flow at all three levels of oscillation output. In no case did an individual vessel seem to be occluded. The excitation oscillation of the bone was established at 2000 Hz in all spatial directions, irrespective of the predefined oscillation output. The application of piezosurgery does not cause the formation of vascular thrombi in the bone. This probably results from the oscillation damping properties of bone. (C) 2011 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 7 条
  • [1] Study on vibration cutting by using piezo-electric actuators
    Tanaka, H
    Sato, M
    Sakamoto, S
    Okamura, S
    Fujiwara, Y
    PROGRESS OF MACHINING TECHNOLOGY, 2004, : 366 - 371
  • [2] A piezo-electric transducer for bone conduction audiometry
    Purcell, D
    Kunov, H
    Madsen, PB
    Cleghorn, W
    CANADIAN MEDICAL AND BIOLOGICAL ENGINEERING SOCIETY, PROCEEDINGS, 1997, : 130 - 131
  • [3] Waviness compensation of precision machining by piezo-electric micro cutting device
    Kim, Jeong-Du
    Kim, Dong-Sik
    International Journal of Machine Tools and Manufacture, 1998, 38 (10-11): : 1305 - 1322
  • [4] Method for definition of piezo-electric module and investigation of it's using boundary
    Akop'yan, V.A.
    Defektoskopiya, 2003, (06): : 29 - 38
  • [5] Experimental investigation of drag reduction of a laminar profile by means of piezo-electric actuators
    Wojciechowski, J
    Szuster, T
    Pietrucha, J
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II FASCICULE B-MECANIQUE PHYSIQUE ASTRONOMIE, 1998, 326 (02): : 85 - 90
  • [6] Autogenous particulate bone collected with a piezo-electric surgical device and bone trap: a microbiological and histomorphometric study
    Sivolella, Stefano
    Berengo, Mario
    Scarin, Marino
    Mella, Francesca
    Martinelli, Franco
    ARCHIVES OF ORAL BIOLOGY, 2006, 51 (10) : 883 - 891
  • [7] Investigation of high temperature vulcanized and room temperature vulcanized silicone rubber based on flexible piezo-electric energy harvesting applications with multi-walled carbon nanotube reinforced composites
    Manikkavel, Amutheesan
    Kumar, Vineet
    Kim, Jaehoon
    Lee, Dong Joo
    Park, Sang Shin
    POLYMER COMPOSITES, 2022, 43 (03) : 1305 - 1318