Y-Stent-Assisted Coiling of Wide-Neck Bifurcation Intracranial Aneurysms: A Meta-Analysis

被引:74
作者
Cagnazzo, F. [1 ]
Limbucci, N. [1 ]
Nappini, S. [1 ]
Renieri, L. [1 ]
Rosi, A. [1 ]
Laiso, A. [1 ]
di Carlo, D. Tiziano [2 ]
Perrini, P. [2 ]
Mangiafico, S. [1 ]
机构
[1] Careggi Univ Hosp, Intervent Neuroradiol Unit, Florence, Italy
[2] Univ Pisa, Cisanello Hosp, Dept Neurosurg, Pisa, Italy
关键词
CEREBRAL-ARTERY ANEURYSMS; ENDOVASCULAR TREATMENT; WOVEN ENDOBRIDGE; CELL STENTS; EMBOLIZATION; CONFIGURATION; MULTICENTER; EXPERIENCE; EFFICACY; COMPLEX;
D O I
10.3174/ajnr.A5900
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Y-stent-assisted coiling for wide-neck intracranial aneurysms required further investigation. PURPOSE: Our aim was to analyze outcomes after Y-stent placement in wide-neck aneurysms. DATA SOURCES: We performed a systematic search of 3 data bases for studies published from 2000 to 2018. STUDY SELECTION: According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting Y-stent-assisted coiling of wide-neck aneurysms. DATA ANALYSIS: Random-effects meta-analysis was used to pool the following: aneurysm occlusion rate, complications, and factors influencing the studied outcomes. DATA SYNTHESIS: We included 27 studies and 750 aneurysms treated with Y-stent placement. The immediate complete/near-complete occlusion rate was 82.2% (352/468; 95% CI, 71.4%-93%; I-2 = 92%), whereas the long-term complete/near-complete occlusion rate was 95.4% (564/598; 95% CI, 93.7%-97%; I-2 = 0%) (mean radiologic follow-up of 14 months). The aneurysm recanalization rate was 3% (20/496; 95% CI, 1.5%-4.5%; I-2 = 0%), and half of the recanalized aneurysms required retreatment. The treatment-related complication rate was 8.9% (63/614; 95% CI, 5.8%-12.1%; I-2 = 44%). Morbidity and mortality after treatment were 2.4% (18/540; 95% CI, 1.2%-3.7%; I-2 = 0%) and 1.1% (5/668; 95% CI, 0.3%-1.9%; I-2 = 0%), respectively. Crossing Y-stent placement was associated with a slightly lower complication rate compared with the kissing configuration (56/572 = 8.4%; 95% CI, 5%-11%; I-2 = 46% versus 4/30 = 12.7%; 95% CI, 3%-24%; I-2 = 0%). Occlusion rates were quite comparable among Enterprise, Neuroform, and LVIS stents, whereas the Enterprise stent was associated with lower rates of complications (8/89 = 6.5%; 95% CI, 1.6%-11%; I-2 = 0%) compared with the others (20/131 = 14%; 95% CI, 5%-26%; I-2 = 69% and 9/64 = 11%; 95% CI, 3%-20%; I-2 = 18%). LIMITATIONS: This was a small, retrospective series. CONCLUSIONS: Y-stent-assisted coiling yields high rates of long-term angiographic occlusion, with a relatively low rate of treatment-related complications. Y-stent placement with a crossing configuration appears to be associated with better outcomes. Although Y-configuration can be obtained using many types of stents with comparable occlusion rates, the Enterprise stent is associated with lower complication rates.
引用
收藏
页码:122 / 128
页数:7
相关论文
共 41 条
[1]   Current Status of the PulseRider in the Treatment of Bifurcation Aneurysms: A Systematic Review [J].
Aguilar-Salinas, Pedro ;
Brasiliense, Leonardo B. C. ;
Walter, Christina M. ;
Hanel, Ricardo A. ;
Dumont, Travis M. .
WORLD NEUROSURGERY, 2018, 115 :288-294
[2]   Hybrid, Y-configured, dual stent-assisted coil embolization in the treatment of wide-necked bifurcation aneurysms [J].
Akgul, Erol ;
Balli, Tugsan ;
Aksungur, Erol H. .
INTERVENTIONAL NEURORADIOLOGY, 2015, 21 (01) :29-39
[3]  
[Anonymous], The Newcastle-Ottawa Scale (NOS) for Assessing the Quality of Nonrandomized Studies in Meta- Analysis
[4]  
[Anonymous], J NEURORADIOL
[5]   Efficacy and Safety of the Woven EndoBridge (WEB) Device for the Treatment of Intracranial Aneurysms: A Systematic Review and Meta-Analysis [J].
Asnafi, S. ;
Rouchaud, A. ;
Pierot, L. ;
Brinjikji, W. ;
Murad, M. H. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) :2287-2292
[6]   The Difficulties and Risks of Y-Stente-Assisted Coiling: A Comparison of First and Second Stenting Procedures [J].
Bang, Jung Soo ;
Kim, Chang Hun ;
Kwon, Bae Ju ;
Park, Sung-Choon ;
Kim, Young .
WORLD NEUROSURGERY, 2016, 88 :146-153
[7]   "Y" and "X" Stent-Assisted Coiling of Complex and Wide-Neck Intracranial Bifurcation Aneurysms [J].
Bartolini, B. ;
Blanc, R. ;
Pistocchi, S. ;
Redjem, H. ;
Piotin, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (11) :2153-2158
[8]   Kissing-Y stenting for endovascular treatment of complex wide necked bifurcation aneurysms using Acandis Acclino stents: results and literature review [J].
Brassel, Friedhelm ;
Melber, Katharina ;
Schlunz-Hendann, Martin ;
Meila, Dan .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (04) :386-395
[9]   Endovascular Treatment of Very Large and Giant Intracranial Aneurysms: Comparison between Reconstructive and Deconstructive Techniques-A Meta-Analysis [J].
Cagnazzo, F. ;
Mantilla, D. ;
Rouchaud, A. ;
Brinjikji, W. ;
Lefevre, P. -H. ;
Dargazanli, C. ;
Gascou, G. ;
Riquelme, C. ;
Perrini, P. ;
di Carlo, D. ;
Bonafe, A. ;
Costalat, V. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (05) :852-858
[10]   Treatment of Middle Cerebral Artery Aneurysms with Flow-Diverter Stents: A Systematic Review and Meta-Analysis [J].
Cagnazzo, F. ;
Mantilla, D. ;
Lefevre, P-H. ;
Dargazanli, C. ;
Gascou, G. ;
Costalat, V. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (12) :2289-2294