Co-registration of optical coherence tomography and X-ray angiography in percutaneous coronary intervention. The Does Optical Coherence Tomography Optimize Revascularization (DOCTOR) fusion study

被引:34
|
作者
Hebsgaard, Lasse [1 ]
Nielsen, Troels Munck [1 ]
Tu, Shengxian [2 ]
Krusell, Lars Romer [1 ]
Maeng, Michael [1 ]
Veien, Karsten Tange [1 ]
Raungaard, Bent [1 ]
Terkelsen, Christian Juhl [1 ]
Kaltoft, Anne [1 ]
Reiber, Johan H. C. [2 ]
Lassen, Jens Flensted [1 ]
Christiansen, Evald Hoj [1 ]
Holm, Niels Ramsing [1 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiol, Skejby, Denmark
[2] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, Leiden, Netherlands
关键词
Optical coherence tomography; Percutaneous coronary intervention; Angiography; Coronary heart disease; Co-registration; Quantitative coronary angiography; INTRAVASCULAR ULTRASOUND GUIDANCE; ELUTING STENT IMPLANTATION; FRACTIONAL FLOW RESERVE; SIDE BRANCH OCCLUSION; IN-VIVO; CLINICAL-OUTCOMES; ARTERY STENOSES; LESIONS; TRIAL; IMPACT;
D O I
10.1016/j.ijcard.2014.12.088
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Intracoronary imaging provides accurate lesion delineation and precise measurements for sizing and positioning of coronary stents. During percutaneous coronary intervention (PCI), it may be challenging to identify corresponding segments between intracoronary imaging and angiography. Computer based online co-registration may aid the target segment identification. Methods: The DOCTOR fusion study was a prospective, single arm, observational study including patients admitted for elective PCI. Optical coherence tomography (OCT) was acquired pre-stent implantation for sizing of stents. The operator subsequently indicated on the angiogram the target area as identified by OCT. Computer based co-registration was performed on-line immediately after pre-stent acquisition to assess feasibility. The cumulated numerical difference between operator based, and computer based co-registration was assessed as the "Operator Registration Error". The operator implanted the stent blind to the co-registrated angiogram. The difference between the co-registered stent border positions and the actual stent deployment border positions was the "Geographic Miss Distance". Results: Twenty-two patients were included in the study. Two patients were excluded due to missing pre or post-OCT acquisitions. Online co-registration pre-stenting was successful in all analyzed cases. The mean "Operator Registration Error" was 5.4 +/- 3.5mm. The mean "Geographic Miss Distance" was 5.4 +/- 2.6mm. Without access to the computer-based co-registration, segments of the target lesion indicated on OCT were left uncovered by stent in 14 patients (70%). Conclusion: Computer based online co-registration of OCT and angiography is feasible. Frequent inaccuracies in operator based registration indicate that computer aided co-registration may reduce errors in corresponding OCT findings to the angiogram. (C) 2015 The Authors. Published by Elsevier Ireland Ltd.
引用
收藏
页码:272 / 278
页数:7
相关论文
共 50 条
  • [11] A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography
    Carlier, Stephane
    Didday, Rich
    Slots, Tristan
    Kayaert, Peter
    Sonck, Jeroen
    El-Mourad, Mike
    Preumont, Nicolas
    Schoors, Dany
    Van Camp, Guy
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2014, 15 (04) : 226 - 232
  • [12] Safety and efficiency of percutaneous coronary intervention using a standardised optical coherence tomography workflow
    Osborn, Eric A.
    Johnson, Michael
    Maksoud, Aziz
    Spoon, Daniel
    Zidar, Frank J.
    Korngold, Ethan C.
    Buccola, Jana
    Cabrera, Hector Garcia
    Rapoza, Richard J.
    West, Nick E. J.
    Rauch, Judah
    EUROINTERVENTION, 2023, 18 (14) : 1178 - +
  • [13] Optical coherence tomography versus angiography to guide percutaneous coronary intervention in patients with in-stent restenosis: an observational study
    Wang, Yi-Fei
    Xu, Tian
    Meng, Pei-Na
    You, Wei
    Xu, Yi
    Kong, Xiao-Han
    Wu, Xiang-Qi
    Wu, Zhi-Ming
    Zhao, Meng-Yao
    Jia, Hai-Bo
    Wang, Feng
    Ye, Fei
    CORONARY ARTERY DISEASE, 2025, 36 (02) : 108 - 116
  • [14] Optical coherence tomography guidance in percutaneous coronary intervention: a meta-analysis of randomized controlled trials
    Sharma, Sharan Prakash
    Rijal, Jharendra
    Dahal, Khagendra
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2019, 34 (02) : 113 - 121
  • [15] Optical coherence tomography imaging for complex percutaneous coronary intervention
    Mamas, Mamas A.
    Mintz, Gary S.
    LANCET, 2024, 404 (10457) : 994 - 995
  • [16] Optical coherence tomography to guide percutaneous coronary intervention of the left main coronary artery: the LEMON study
    Amabile, Nicolas
    Range, Gregoire
    Souteyrand, Geraud
    Godin, Matthieu
    Boussaada, Mohamed Mehdi
    Meneveau, Nicolas
    Cayla, Guillaume
    Casassus, Frederic
    Lefevre, Thierry
    Hakim, Radwane
    Bagdadi, Imane
    Motreff, Pascal
    Caussin, Christophe
    EUROINTERVENTION, 2021, 17 (02) : E124 - U55
  • [17] Optical Coherence Tomography to Optimize Results of Percutaneous Coronary Intervention in Patients with Non-ST-Elevation Acute Coronary Syndrome Results of the Multicenter, Randomized DOCTORS Study (Does Optical Coherence Tomography Optimize Results of Stenting)
    Meneveau, Nicolas
    Souteyrand, Geraud
    Motreff, Pascal
    Caussin, Christophe
    Amabile, Nicolas
    Ohlmann, Patrick
    Morel, Olivier
    Lefrancois, Yoann
    Descotes-Genon, Vincent
    Silvain, Johanne
    Braik, Nassim
    Chopard, Romain
    Chatot, Marion
    Ecarnot, Fiona
    Tauzin, Helene
    Van Belle, Eric
    Belle, Loic
    Schiele, Francois
    CIRCULATION, 2016, 134 (13) : 906 - +
  • [18] In-stent fractional flow reserve variations and related optical coherence tomography findings: the FFR-OCT co-registration study
    Pyxaras, Stylianos A.
    Adriaenssens, Tom
    Barbato, Emanuele
    Ughi, Giovanni Jacopo
    Di Serafino, Luigi
    De Vroey, Frederic
    Toth, Gabor
    Tu, Shengxian
    Reiber, Johan H. C.
    Bax, Jeroen J.
    Wijns, William
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (04) : 495 - 502
  • [19] Coronary Angiography, Intravascular Ultrasound, and Optical Coherence Tomography for Guiding of Percutaneous Coronary Intervention: A Systematic Review and Network Meta-Analysis
    Giacoppo, Daniele
    Laudani, Claudio
    Occhipinti, Giovanni
    Spagnolo, Marco
    Greco, Antonio
    Rochira, Carla
    Agnello, Federica
    Landolina, Davide
    Mauro, Maria Sara
    Finocchiaro, Simone
    Mazzone, Placido Maria
    Ammirabile, Nicola
    Imbesi, Antonino
    Raffo, Carmelo
    Buccheri, Sergio
    Capodanno, Davide
    CIRCULATION, 2024, 149 (14) : 1065 - 1086
  • [20] In Vivo Flow Simulation at Coronary Bifurcation Reconstructed by Fusion of 3-Dimensional X-ray Angiography and Optical Coherence Tomography
    Tu, Shengxian
    Pyxaras, Stylianos A.
    Li, Yingguang
    Barbato, Emanuele
    Reiber, Johan H. C.
    Wijns, William
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (02) : E15 - +