An alternative method for smear preparation of fine-needle aspiration cytology of cystic thyroid lesions: Evaluation of sample adequacy

被引:0
作者
Xavier-Junior, Jose Candido Caldeira [1 ,2 ]
Zogheib, Rodrigo Jose Pizzello [1 ,2 ]
Camilo-Junior, Deolino Joao [1 ]
D'avilla, Solange Correa Garcia Pires [1 ,3 ]
Mattar, Neivio Jose [1 ]
机构
[1] Pathol Inst Aracatuba, Rua Floriano Peixoto 808, BR-16015000 Sao Paulo, Brazil
[2] Ctr Univ Catolico Unisalesiano Auxilium, Sch Med, Sao Paulo, Brazil
[3] Sao Jose do Rio Preto Med Sch FAMERP, Dept Pathol, Sao Paulo, Brazil
关键词
cysts; cytology; fine-needle aspiration biopsy; methods; thyroid; BIOPSY; FLUID;
D O I
10.1002/dc.24525
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Cystic thyroid lesions represent one of the most common causes of unsatisfactory fine-needle aspiration sampling. Thus, it is important to access the maximum number of follicular cells from cystic fluid in order to reduce unsatisfactory rates. We compared the traditional method of smearing with an alternative one. Methods For each thyroid nodule, two smears were collected. Each smear was prepared using a distinct approach: either using the traditional technique or the alternative. Clinical data were taken from cytopathological request forms. The cytological aspects of the smears (eg, adequacy and number of cells) were observed during microscopy analysis. No cases were found to be suspicious for malignancy during ultrasound analysis (categories TR1 or TR2 according to ACR TI-RADS). Results Thirty-five cases were analyzed. For smears prepared using both the traditional and the alternative techniques, 20 and 4 cases, respectively, were unsatisfactory. In the 20 unsatisfactory traditional smear cases, 9 (45%) showed enough cells for diagnosis in cytospin and/or cell block samples; the four unsatisfactory alternative method cases showed the same. There was a statistical difference between the two methods of collecting a smear concerning sample adequacy (P< .001), but there was no statistical difference regarding the cellularity (P= .842). Conclusion In our data, the alternative method of using only one slide and the needle tip had higher rates of adequate sampling. Since it is cost effective and does not change the cytological analysis, this proposed alternative method can be useful in cases of cystic thyroid lesions.
引用
收藏
页码:1054 / 1057
页数:4
相关论文
共 50 条
[21]   Medullary carcinoma of the thyroid - Accuracy of diagnosis by fine-needle aspiration cytology [J].
Forrest, CH ;
Frost, FA ;
de Boer, WB ;
Spagnolo, DV ;
Whitaker, D ;
Sterrett, GF .
CANCER CYTOPATHOLOGY, 1998, 84 (05) :295-302
[22]   EVALUATION OF FINE-NEEDLE ASPIRATION (FNA) CYTOLOGY IN THE DIAGNOSIS OF THYROID-NODULES [J].
HOLLEMAN, F ;
HOEKSTRA, JBL ;
RUITENBERG, HM .
CYTOPATHOLOGY, 1995, 6 (03) :168-175
[23]   Extracapsular Cervical Hematoma After Thyroid Fine-Needle Aspiration Cytology [J].
Correia, Sara ;
Ramalho, Diogo ;
Rocha, Gustavo ;
Oliveira, Maria J. .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
[24]   Fine-needle aspiration biopsy cytology of hyalinizing trabecular adenomas of the thyroid [J].
Akin, MRM ;
Nguyen, GK .
DIAGNOSTIC CYTOPATHOLOGY, 1999, 20 (02) :90-94
[25]   Fine-Needle Aspiration Cytology of Thyroid Nodule: Does the Needle Matter? [J].
Cappelli, Carlo ;
Pirola, Ilenia ;
Gandossi, Elena ;
De Martino, Elena ;
Agosti, Barbara ;
Castellano, Maurizio .
SOUTHERN MEDICAL JOURNAL, 2009, 102 (05) :498-501
[26]   Fine-needle aspiration cytology of soft tissue lesions: Diagnostic challenges [J].
Domanski, Henryk A. .
DIAGNOSTIC CYTOPATHOLOGY, 2007, 35 (12) :768-773
[27]   Effect of a Biopsy Center on Adequacy Rates of Thyroid Nodule Fine-Needle Aspiration [J].
Leung, Vincent A. ;
Kirpalani, Anish ;
Mnatzakanian, Gevork ;
Colak, Errol ;
Vlachou, Paraskevi A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (02) :358-362
[28]   Evaluation of Thyroid Lesions by Fine Needle Aspiration Cytology According to Bethesda System [J].
Jain, Disha ;
Sharma, Rashmi ;
Pachori, Geeta ;
Bayla, Tushar .
INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2023, 75 (02) :457-462
[29]   Utility of fine-needle aspiration cytology in the identification of parathyroid lesions [J].
Kumari, Niraj ;
Mishra, Deepti ;
Pradhan, Roma ;
Agarwal, Amit ;
Krishnani, Narendra .
JOURNAL OF CYTOLOGY, 2016, 33 (01) :17-21
[30]   Evaluation of Thyroid Lesions by Fine Needle Aspiration Cytology According to Bethesda System [J].
Disha Jain ;
Rashmi Sharma ;
Geeta Pachori ;
Tushar Bayla .
Indian Journal of Otolaryngology and Head & Neck Surgery, 2023, 75 :457-462