An alternative method for smear preparation of fine-needle aspiration cytology of cystic thyroid lesions: Evaluation of sample adequacy

被引:1
|
作者
Xavier-Junior, Jose Candido Caldeira [1 ,2 ]
Zogheib, Rodrigo Jose Pizzello [1 ,2 ]
Camilo-Junior, Deolino Joao [1 ]
D'avilla, Solange Correa Garcia Pires [1 ,3 ]
Mattar, Neivio Jose [1 ]
机构
[1] Pathol Inst Aracatuba, Rua Floriano Peixoto 808, BR-16015000 Sao Paulo, Brazil
[2] Ctr Univ Catolico Unisalesiano Auxilium, Sch Med, Sao Paulo, Brazil
[3] Sao Jose do Rio Preto Med Sch FAMERP, Dept Pathol, Sao Paulo, Brazil
关键词
cysts; cytology; fine-needle aspiration biopsy; methods; thyroid; BIOPSY; FLUID;
D O I
10.1002/dc.24525
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Cystic thyroid lesions represent one of the most common causes of unsatisfactory fine-needle aspiration sampling. Thus, it is important to access the maximum number of follicular cells from cystic fluid in order to reduce unsatisfactory rates. We compared the traditional method of smearing with an alternative one. Methods For each thyroid nodule, two smears were collected. Each smear was prepared using a distinct approach: either using the traditional technique or the alternative. Clinical data were taken from cytopathological request forms. The cytological aspects of the smears (eg, adequacy and number of cells) were observed during microscopy analysis. No cases were found to be suspicious for malignancy during ultrasound analysis (categories TR1 or TR2 according to ACR TI-RADS). Results Thirty-five cases were analyzed. For smears prepared using both the traditional and the alternative techniques, 20 and 4 cases, respectively, were unsatisfactory. In the 20 unsatisfactory traditional smear cases, 9 (45%) showed enough cells for diagnosis in cytospin and/or cell block samples; the four unsatisfactory alternative method cases showed the same. There was a statistical difference between the two methods of collecting a smear concerning sample adequacy (P< .001), but there was no statistical difference regarding the cellularity (P= .842). Conclusion In our data, the alternative method of using only one slide and the needle tip had higher rates of adequate sampling. Since it is cost effective and does not change the cytological analysis, this proposed alternative method can be useful in cases of cystic thyroid lesions.
引用
收藏
页码:1054 / 1057
页数:4
相关论文
共 50 条
  • [1] Sensitivity Evaluation of Fine-Needle Aspiration Cytology in Thyroid Lesions
    Dobrinja, Chiara
    Trevisan, Giuliano
    Liguori, Gennaro
    Romano, Andrea
    Zanconati, Fabrizio
    DIAGNOSTIC CYTOPATHOLOGY, 2009, 37 (03) : 230 - 235
  • [2] Comparison of fine-needle aspiration with fine-needle capillary cytology in thyroid nodules
    Hatami, H.
    Samsami, M.
    Movahedinia, S.
    Salehi, B.
    Movahedinia, M.
    Ardeshir, M.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2023, 105 (02) : 162 - 165
  • [3] Fine-needle aspiration in the evaluation of thyroid lesions in children
    Kaur, Jasleen
    Srinivasan, Radhika
    Arora, Sandeep Kumar
    Rajwanshi, Arvind
    Saikia, Uma Nahar
    Dutta, Pinaki
    Gupta, Nalini
    Nijhawan, Raje
    Dey, Pranab
    DIAGNOSTIC CYTOPATHOLOGY, 2012, 40 : E33 - E37
  • [4] Intrinsic factors affecting adequacy of thyroid nodule fine-needle aspiration cytology
    Grani, Giorgio
    Calvanese, Anna
    Carbotta, Giovanni
    D'Alessandri, Mimma
    Nesca, Angela
    Bianchini, Marta
    Del Sordo, Marianna
    Fumarola, Angela
    CLINICAL ENDOCRINOLOGY, 2013, 78 (01) : 141 - 144
  • [5] Evaluation of fine needle aspiration cytology as a screening tool in thyroid lesions
    Mamoon, Nadira
    Jamy, Rabia
    Khan, Asna Haroon
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2013, 63 (09) : 1120 - 1123
  • [6] Fine-needle aspiration cytology in the diagnosis of parotid lesions
    Piccioni, L. O.
    Fabiano, B.
    Gemma, M.
    Sarandria, D.
    Bussi, M.
    ACTA OTORHINOLARYNGOLOGICA ITALICA, 2011, 31 (01) : 1 - 4
  • [7] Grading of Soft Tissue Sarcomas on Fine-Needle Aspiration Cytology Smear
    Mallik, Mrinmay Kumar
    Dey, Pranab
    Gupta, Subhash Kumari
    Vasishta, Rakesh Kumar
    DIAGNOSTIC CYTOPATHOLOGY, 2010, 38 (02) : 109 - 112
  • [8] An Automatable Method for Determining Adequacy of Thyroid Fine-Needle Aspiration Samples
    Schmolze, Daniel B.
    Fischer, Andrew H.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2019, 143 (09) : 1084 - 1088
  • [9] Thyroid fine-needle aspiration cytology: Is there a place to virtual cytology?
    Gerhard, Rene
    Teixeira, Sofia
    da Rocha, Adriana Gaspar
    Schmitt, Fernando
    DIAGNOSTIC CYTOPATHOLOGY, 2013, 41 (09) : 793 - 798
  • [10] Comparison of Conventional Smear and Liquid-Based Cytology in Adequacy of Thyroid Fine-Needle Aspiration Biopsies without an Accompanying Cytopathologist
    Sayer, Ayse Ozdal
    Mut, Deniz Turkyilmaz
    Von Bodelschwingh, Bade
    Ozguven, Banu Yilmaz
    Sahin, Cennet
    MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL, 2022, 56 (03): : 353 - 359