Comparison of air-sealing characteristics of tapered- vs. cylindrical-shaped high-volume, low-pressure tube cuffs

被引:32
作者
Madjdpour, C. [1 ]
Mauch, J. [1 ]
Dave, M. H. [1 ]
Spielmann, N. [1 ]
Weiss, M. [1 ]
机构
[1] Univ Childrens Hosp Zurich, Dept Anaesthesia, Zurich, Switzerland
关键词
TRACHEAL TUBE; ENDOTRACHEAL-TUBES; GEL LUBRICATION; LEAKAGE; FLUID; PNEUMONIA;
D O I
10.1111/j.1399-6576.2011.02542.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background This study aimed at comparing air-sealing characteristics of the new tapered-shaped tracheal tube cuffs with cylindrical tube cuffs. Methods Tracheal tubes with tapered-shaped polyurethane (PU) and polyvinyl chloride (PVC) cuffs as well as standard cylindrical-shaped cuffs made of PU and PVC (Covidien, Athlone, Ireland) were investigated. A tracheal model attached to a test lung was intubated, and cuffs were inflated to 10, 15, 20, 25 and 30 cm H 2O. The test lung was ventilated with intermittent positive pressure ventilation at peak inspiratory pressures (PIPs) of 20 and 25 cm H 2O. Air leakage was assessed by spirometry and measurement of sevoflurane concentration passing the cuff at the upper cuff border using an anaesthetic gas analyser. Experiments were repeated four times with new tracheal tubes for each run. Statistical comparisons were done using Mann-Whitney U-test with level of significance at P < 0.05. Results The tapered-shaped PVC tube cuff demonstrated a significantly lower air leakage determined by spirometry than the cylindrical-shaped cuff at both PIPs (20 and 25 cm H 2O). Similarly, sevoflurane leakage was less with the tapered PVC cuff particularly at higher cuff pressures. With the PU cuff, reduction in air leakage by a tapered-shaped compared with a cylindrical-shaped tube cuff was not significant. Conclusions A tapered-shaped tube cuff considerably improves air-sealing characteristics of PVC tube cuffs and allows thereby reducing cuff pressure required for sufficient ventilation. In tube cuffs made of PU that exhibits superior sealing characteristics compared with PVC, a tapered shape failed to result in a further reduction of air leakage. © 2011 The Acta Anaesthesiologica Scandinavica Foundation.
引用
收藏
页码:230 / 235
页数:6
相关论文
共 26 条
  • [1] Leakage of fluid around high-volume, low-pressure cuffs - A comparison of four tracheal tubes
    Asai, T
    Shingu, K
    [J]. ANAESTHESIA, 2001, 56 (01) : 38 - 42
  • [2] INTRACUFF PRESSURES IN ENDOTRACHEAL AND TRACHEOSTOMY TUBES - RELATED CUFF PHYSICAL CHARACTERISTICS
    BERNHARD, WN
    YOST, L
    JOYNES, D
    COTHALIS, S
    TURNDORF, H
    [J]. CHEST, 1985, 87 (06) : 720 - 725
  • [3] PRESSURES ON ENDOTRACHEAL-TUBE CUFFS
    BLACK, AMS
    SEEGOBIN, RD
    [J]. ANAESTHESIA, 1981, 36 (05) : 498 - 511
  • [4] Gel lubrication of the tracheal tube cuff reduces pulmonary aspiration
    Blunt, MC
    Young, PJ
    Patil, A
    Haddock, A
    [J]. ANESTHESIOLOGY, 2001, 95 (02) : 377 - 381
  • [5] Tracheomalacia and tracheobronchomalacia in children and adults - An in-depth review
    Carden, KA
    Boiselle, PM
    Waltz, DA
    Ernst, A
    [J]. CHEST, 2005, 127 (03) : 984 - 1005
  • [6] Tracheal fluid leakage in benchtop trials: comparison of static versus dynamic ventilation model with and without lubrication
    Dave, Mital H.
    Koepfer, Nelly
    Madjdpour, Caveh
    Frotzler, Angela
    Weiss, Markus
    [J]. JOURNAL OF ANESTHESIA, 2010, 24 (02) : 247 - 252
  • [7] Air leakage around endotracheal tube cuffs
    Dullenkopf, A
    Schmitz, A
    Frei, M
    Gerber, AC
    Weiss, M
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (06) : 448 - 453
  • [8] Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube
    Dullenkopf, A
    Gerber, A
    Weiss, M
    [J]. INTENSIVE CARE MEDICINE, 2003, 29 (10) : 1849 - 1853
  • [9] Influence of airway pressure on minimum occlusive endotracheal tube cuff pressure
    Guyton, DC
    Barlow, MR
    Besselievre, TR
    [J]. CRITICAL CARE MEDICINE, 1997, 25 (01) : 91 - 94
  • [10] What to do when an endotracheal tube cuff leaks
    Ho, AMH
    Contardi, LH
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 40 (03) : 486 - 487