A Review of Results From Thermal Cycling Tests of Hydrogenerator Stator Windings

被引:35
作者
Istad, Maren [1 ]
Runde, Magne [1 ]
Nysveen, Arne [2 ]
机构
[1] SINTEF Energy Res, NO-7465 Trondheim, Norway
[2] Norwegian Univ Sci & Technol, Dept Elect Power Engn, NO-7491 Trondheim, Norway
关键词
Hydrogenerators; intermittent operation; stator groundwall insulation; thermal cycling tests; PARTIAL DISCHARGE; EPOXY/MICA INSULATION; VOLTAGE ENDURANCE; SYSTEMS; BARS; LIFE; ACCELERATION; DEGRADATION; STRESSES;
D O I
10.1109/TEC.2011.2127479
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermal cycling of generators, occurring during intermittent operation of power stations, increases the thermomechanical stress on the stator groundwall insulation and can, therefore, contribute to failure of the generator. Thermal cycling stresses can, to some extent, be replicated and accelerated in laboratory tests. Such tests are performed to ascertain whether a new stator winding insulation system can handle intermittent operation, to evaluate the relative difference between different types of insulations or to investigate degradation processes and failure mechanisms. Results from thermal cycling tests of hydrogenerator stator windings are reviewed. Only stator windings of air-cooled hydrogenerators with thermoset groundwall insulation of mica-epoxy or mica-polyester are considered. The published literature of laboratory experiments performed in order to study effects of thermal cycling on groundwall insulation through different types of diagnostic measurements is described and discussed. Partial discharge (PD) and tan delta measurements gave, in some cases, an indication of a trend in the condition during thermal cycling, while in other cases it was difficult to interpret the test results. Many agree that measurement of breakdown voltage of stator windings can give an indication of the aging and remaining lifetime of the insulation. The ability of other measurements such as tan delta, PD, and voltage endurance to assess the remaining lifetime of the stator winding is less convincing since the results vary greatly.
引用
收藏
页码:890 / 903
页数:14
相关论文
共 69 条
[61]   Symptoms of Winding Insulation Aging After 37 Years of Service Life in a Hydrogenerator [J].
Weiers, Tilman .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (01) :20-24
[62]  
WENDEL C, P 2006 IEEE INT S EL, P97
[63]  
WICHMANN A, 1977, IEEE T POWER AP SYST, V96, P255, DOI 10.1109/T-PAS.1977.32332
[64]   RELIABILITY AND TESTING OF HIGH-VOLTAGE STATOR INSULATION FOR LARGE ROTATING MACHINES [J].
WICHMANN, A .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, 91 (05) :2230-&
[65]   Quality evaluation of stator coils and bars under thennal cycling stress [J].
Zhu, H. ;
Morton, C. .
CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, :384-+
[66]  
2004, EVALUATION QUALIFICA
[67]  
1991, INT ELECTROTECHNICAL, pCH212
[68]  
2003, HYDROGENERATOR FAILU
[69]  
2000, FUNCTIONAL EVALUATIO