Congenital Heart Disease: Cardiovascular MR Imaging by Using an Intravascular Blood Pool Contrast Agent

被引:29
作者
Makowski, Marcus R. [1 ,2 ]
Wiethoff, Andrea J. [1 ,2 ,3 ]
Uribe, Sergio [1 ,2 ]
Parish, Victoria [1 ,2 ]
Botnar, Rene M. [1 ,2 ]
Bell, Aaron [1 ,2 ]
Kiesewetter, Christoph [1 ,2 ]
Beerbaum, Philipp [1 ,2 ]
Jansen, Christian H. P. [1 ,2 ]
Razavi, Reza [1 ,2 ]
Schaeffter, Tobias [1 ,2 ]
Greil, Gerald F. [1 ,2 ]
机构
[1] Kings Coll London, Div Imaging Sci, British Heart Fdn Ctr, Biomed Res Ctr Guys, London SE1 7EH, England
[2] Kings Coll London, St Thomas Hosp, Natl Hlth Serv Fdn Trust, London SE1 7EH, England
[3] Philips Healthcare, Guildford, Surrey, England
关键词
MAGNETIC-RESONANCE ANGIOGRAPHY; RECOMMENDATIONS; VISUALIZATION;
D O I
10.1148/radiol.11102327
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the image quality and diagnostic performance of a contrast agent-specific inversion-recovery (IR) steady-state free precession (SSFP) magnetic resonance (MR) imaging sequence performed by using an intravascular contrast agent (gadofosveset trisodium) with those of a commonly used T2-prepared SSFP sequence performed by using an extravascular (gadopentetate dimeglumine) and an intravascular (gadofosveset trisodium) contrast agent in patients with congenital heart disease (CHD). Materials and Methods: The local ethics committee and the United Kingdom Medicines and Healthcare products Regulatory Agency approved this study. Patient informed consent was obtained. Twenty-three patients with CHD were examined by using a 1.5-T MR imaging unit and a 32-channel coil. Gadopentetate dimeglumine and gadofosveset trisodium were used in the same patient on consecutive days. Vessel wall sharpness, contrast-to-noise ratios (CNRs), image quality, and diagnostic performance achieved by using the IR SSFP sequence with gadofosveset trisodium were compared with those achieved by using the T2-prepared SSFP sequence with gadopentetate dimeglumine and gadofosveset trisodium and with those achieved at respective contrast material-enhanced MR angiographic examinations. The Wilcoxon rank sum test was used to compare categoric variables; t tests were used to compare continuous variables. Results: Use of the IR SSFP sequence with gadofosveset trisodium significantly improved vessel wall sharpness, CNRs, and image quality (P <.05 for all) for all investigated intra-and extracardiac structures compared with the T2-prepared SSFP sequence with gadopentetate dimeglumine and gadofosveset trisodium and the respective contrast-enhanced MR angiographic examinations. With use of the IR SSFP sequence with gadofosveset trisodium, new, unsuspected diseases (five [ 22%] of 23) were diagnosed, while other diseases could be excluded (15 [ 65%] of 23). Information available from echocardiography (n = 23), conventional angiography (n = 4), and/or surgery (n = 1) confirmed all diagnoses. Conclusion: IR SSFP with gadofosveset trisodium improved image quality and diagnostic performance, allowing a more accurate and complete assessment of cardiovascular anatomy in patients with CHD compared with T2-prepared SSFP with gadopentetate dimeglumine and gadofosveset trisodium and respective contrast-enhanced MR angiographic examinations. (C) RSNA, 2011
引用
收藏
页码:680 / 688
页数:9
相关论文
共 50 条
  • [31] Peripheral MRA with k-space Segmentation and Blood-Pool Contrast Agent
    Kinner, Sonja
    Zenge, Michael O.
    Heilmaier, Christina
    de Greiff, Armin
    Vogt, Florian M.
    Ladd, Mark E.
    Barkhausen, Joerg
    Quick, Harald H.
    ACADEMIC RADIOLOGY, 2011, 18 (01) : 113 - 119
  • [32] Equilibrium phase MR angiography of the aortic arch and abdominal vasculature with the blood pool contrast agent CMD-A2-Gd-DOTA in pigs
    Kroft, LJM
    Doornbos, J
    Benderbous, S
    de Roos, A
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (06): : 777 - 785
  • [33] Three-dimensional Dual-Phase Whole-Heart MR Imaging: Clinical Implications for Congenital Heart Disease
    Hussain, Tarique
    Lossnitzer, Dirk
    Bellsham-Revell, Hannah
    Valverde, Israel
    Beerbaum, Philipp
    Razavi, Reza
    Bell, Aaron J.
    Schaeffter, Tobias
    Botnar, Rene M.
    Uribe, Sergio A.
    Greil, Gerald F.
    RADIOLOGY, 2012, 263 (02) : 547 - 554
  • [34] Dixon-based fat-free MR-angiography compared to first pass and steady-state high-resolution MR-angiography using a blood pool contrast agent
    Homsi, Rami
    Gieseke, Juergen
    Kukuk, Guido M.
    Traeber, Frank
    Willinek, Winfried A.
    Schild, Hans H.
    Hadizadeh, Dariusch R.
    MAGNETIC RESONANCE IMAGING, 2015, 33 (09) : 1035 - 1042
  • [35] Role of Cardiovascular MR Imaging and MR Angiography in Patients with Pulmonary Vascular Disease
    Trabzonlu, Tugce Agirlar
    Allen, Bradley D.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2025, 63 (02) : 279 - 291
  • [36] 3D Whole Heart Imaging for Congenital Heart Disease
    Greil, Gerald
    Tandon, Animesh
    Vieira, Miguel Silva
    Hussain, Tarique
    FRONTIERS IN PEDIATRICS, 2017, 5
  • [37] Modern Perforator Flap Imaging with High-Resolution Blood Pool MR Angiography
    Kagen, Alexander C.
    Hossain, Rydhwana
    Dayan, Erez
    Maddula, Soumya
    Samson, William
    Dayan, Joseph
    Smith, Mark L.
    RADIOGRAPHICS, 2015, 35 (03) : 901 - 915
  • [38] High Spatial Resolution and High Contrast Visualization of Brain Arteries and Veins: Impact of Blood Pool Contrast Agent and Water-Selective Excitation Imaging at 3T
    Spuentrup, E.
    Jacobs, J. E.
    Kleimann, J. F.
    Wiethoff, A. J.
    Poggenborg, J.
    Brinker, G.
    Loehr, M.
    Hartmann, W. Moeller
    Botnar, R. M.
    Emestus, R. I.
    Lackner, K. J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (12): : 1097 - 1104
  • [39] Contrast-enhanced MR angiography: does a higher relaxivity MR contrast agent permit a reduction of the dose administered for routine vascular imaging applications?
    Xiaoying Xing
    Xiangzhu Zeng
    Xuan Li
    Qiang Zhao
    Miles A. Kirchin
    Gianpaolo Pirovano
    Xiaoying Wang
    Yuan Li
    Roberto Iezzi
    Francesco De Cobelli
    La radiologia medica, 2015, 120 : 239 - 250
  • [40] Contrast-enhanced MR angiography: does a higher relaxivity MR contrast agent permit a reduction of the dose administered for routine vascular imaging applications?
    Xing, Xiaoying
    Zeng, Xiangzhu
    Li, Xuan
    Zhao, Qiang
    Kirchin, Miles A.
    Pirovano, Gianpaolo
    Wang, Xiaoying
    Li, Yuan
    Iezzi, Roberto
    De Cobelli, Francesco
    RADIOLOGIA MEDICA, 2015, 120 (02): : 239 - 250