High-sensitivity cardiac troponin assays: Answers to frequently asked questions

被引:28
作者
Chenevier-Gobeaux, Camille [1 ]
Bonnefoy-Cudraz, Eric [2 ]
Charpentier, Sandrine [3 ]
Dehoux, Monique [4 ]
Lefevre, Guillaume [5 ]
Meune, Christophe [6 ,7 ]
Ray, Patrick [8 ,9 ,10 ]
机构
[1] GH Cochin Broca Hotel Dieu, AP HP, HUPC, Lab Biochim, F-75014 Paris, France
[2] Hosp Civils Lyon, Hop Louis Pradel, Serv Cardiol, F-69002 Lyon, France
[3] Univ Toulouse 3, CHU Toulouse, Hop Rangueil, Serv Accueil Urgences,INSERM,UMR 1027,Equipe 5, F-31400 Toulouse, France
[4] Hop Bichat Claude Bernard, AP HP, HUPNVS, Lab Biochim, F-75018 Paris, France
[5] Hop Tenon, AP HP, HUEP, Lab Biochim & Hormonol, F-75020 Paris, France
[6] Hop Avicenne, AP HP, HUPSSD, Serv Cardiol, F-93000 Bobigny, France
[7] Univ Paris 13, F-93000 Paris, France
[8] Hop Tenon, AP HP, HUEP, Serv Accueil Urgences, F-75020 Paris, France
[9] Univ Paris 06, F-75013 Paris, France
[10] Univ Paris 06, AP HP, DHU Fighting Ageing & Stress FAST, F-75013 Paris, France
关键词
Troponin; High-sensitivity; Myocardial infarction; Acute coronary syndrome; Chest pain; ACUTE MYOCARDIAL-INFARCTION; ACUTE CORONARY SYNDROME; EARLY-DIAGNOSIS; 99TH PERCENTILE; SERIAL CHANGES; I ASSAY; ELEVATION; DETERMINANTS; MORTALITY; ABSOLUTE;
D O I
10.1016/j.acvd.2014.11.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiac troponin (cm) assays have quickly gained in analytical sensitivity to become what are termed 'high-sensitivity cardiac troponin' (hs-cTn) assays, bringing a flurry of dense yet incomplete literature data. The net result is that cTn assays are not yet standardized and there are still no consensus-built data on how to use and interpret cTn assay results. To address these issues, the authors take cues and clues from multiple disciplines to bring responses to frequently asked questions. In brief, the effective use of hs-cTn hinges on knowing: specific assay characteristics, particularly precision at the 99th percentile of a reference population; factors of variation at the 99th percentile value; and the high-individuality of hs-cTn assays, for which the notion of individual kinetics is more informative than straight reference to 'normal' values. The significance of patterns of change between two assay measurements has not yet been documented for every hs-cTn assay. Clinicians need to work hand-in-hand with medical biologists to better understand how to use hs-cTn assays in routine practice. (C) 2014 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:132 / 149
页数:18
相关论文
共 50 条
[1]   Coprevalence of Autoantibodies to Cardiac Troponin I and T in Normal Blood Donors [J].
Adamczyk, Maciej ;
Brashear, R. Jeffrey ;
Mattingly, Phillip G. .
CLINICAL CHEMISTRY, 2010, 56 (04) :676-677
[2]  
[Anonymous], TROPONIN ASSAY ANAL
[3]  
[Anonymous], BIOL VARIATION PRINC
[4]   National Academy of Clinical Biochemistry and IFCC Committee for Standardization of Markers of Cardiac Damage Laboratory Medicine Practice Guidelines: Analytical issues for biomarkers of heart failure [J].
Apple, Fred S. ;
Wu, Alan H. B. ;
Jaffe, Allan S. ;
Panteghini, Mauro ;
Christenson, Robert H. ;
Christenson, Robert H. ;
Apple, Fred S. ;
Cannon, Christopher P. ;
Francis, Gary ;
Jesse, Robert L. ;
Morrow, David A. ;
Newby, L. Kristen ;
Storrow, Alan B. ;
Tang, W. H. Wilson ;
Wu, Alan H. B. ;
Apple, Fred S. ;
Christenson, Robert H. ;
Jaffe, Allan S. ;
Pagani, Franca ;
Tate, Jillian ;
Ordonez-Llanos, Jordi ;
Mair, Johannes .
CIRCULATION, 2007, 116 (05) :E95-E98
[5]   Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays [J].
Apple, Fred S. ;
Collinson, Paul O. .
CLINICAL CHEMISTRY, 2012, 58 (01) :54-61
[6]   Circulating Immunoreactive Cardiac Troponin Forms Determined by Gel Filtration Chromatography after Acute Myocardial Infarction [J].
Bates, Katharine J. ;
Hall, Elizabeth M. ;
Fahie-Wilson, Michael N. ;
Kindler, Heiko ;
Bailey, Clare ;
Lythall, David ;
Lamb, Edmund J. .
CLINICAL CHEMISTRY, 2010, 56 (06) :952-958
[7]  
Biener Moritz, 2013, Int J Cardiol, V167, P1134, DOI 10.1016/j.ijcard.2012.09.122
[8]   Cardiac troponin: a critical review of the case for point-of-care testing in the ED [J].
Bingisser, Roland ;
Cairns, Charles ;
Christ, Michael ;
Hausfater, Pierre ;
Lindahl, Bertil ;
Mair, Johannes ;
Panteghini, Mauro ;
Price, Christopher ;
Venge, Per .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (08) :1639-1649
[9]   Peak and Fixed-Time High-Sensitive Troponin for Prediction of Infarct Size, Impaired Left Ventricular Function, and Adverse Outcomes in Patients With First ST-Segment Elevation Myocardial Infarction Receiving Percutaneous Coronary Intervention [J].
Boden, Helen ;
Ahmed, Tarek A. N. ;
Velders, Matthijs A. ;
van der Hoeven, Bas L. ;
Hoogslag, Georgette E. ;
Bootsma, Marianne ;
le Cessie, Saskia ;
Cobbaert, Christa M. ;
Delgado, Victoria ;
van der Laarse, Arnoud ;
Schalij, Martin J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (10) :1387-1393
[10]   A comprehensive review of upper reference limits reported for (high-)sensitivity cardiac troponin assays: the challenges that lie ahead [J].
Cardinaels, Eline P. M. ;
Mingels, Alma M. A. ;
Jacobs, Leo H. J. ;
Meex, Steven J. R. ;
Bekers, Otto ;
van Dieijen-Visser, Marja P. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (05) :791-806