Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study

被引:23
|
作者
Kingston, Mitchell J. [1 ,2 ]
Perriman, Diana M. [1 ,2 ]
Neeman, Teresa [3 ]
Smith, Paul N. [1 ,2 ]
Webb, Alexandra L. [1 ]
机构
[1] Australian Natl Univ, Sch Med, Coll Med Biol & Environm, 54 Mills Rd, Canberra, ACT 2601, Australia
[2] Canberra Hosp, TORU, Canberra, ACT, Australia
[3] Australian Natl Univ, Stat Consulting Unit, Canberra, ACT, Australia
关键词
micro-computed tomography; angiography; barium sulfate; lead oxide; contrast media; INJECTION TECHNIQUE; FLAP; ANATOMY;
D O I
10.1002/cmmi.1695
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra-and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 50 条
  • [21] Three-dimensional electron beam CT angiography in the diagnosis of intracranial aneurysms
    Chen, S
    Shen, TZ
    Chen, XR
    CHINESE MEDICAL JOURNAL, 1999, 112 (08) : 739 - 742
  • [22] Three dimensional visualisation and morphometry of bone samples studied in microcomputed tomography (micro-CT)
    Leszczynski, B.
    Skrzat, J.
    Kozerska, M.
    Wrobel, A.
    Walocha, J.
    FOLIA MORPHOLOGICA, 2014, 73 (04) : 422 - 428
  • [23] Gadopentetate dimeglumine:: A possible alternative contrast agent for CT angiography of the aorta
    Peña, CS
    Kaufman, JA
    Geller, SC
    Waltman, AC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (01) : 23 - 24
  • [24] Three-dimensional CT angiography assessment of the impact of the dermis and the subdermal plexus in DIEP flap perfusion
    Laungani, Alexis T.
    Van Alphen, Nick
    Christner, Jodie A.
    Lachman, Nirusha
    Pawlina, Wojciech
    Ballman, Karla V.
    St-Cyr, Michel
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2015, 68 (04): : 525 - 530
  • [25] Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography
    Hany, TF
    Debatin, JF
    Leung, DA
    Pfammatter, T
    RADIOLOGY, 1997, 204 (02) : 357 - 362
  • [26] Carotid artery stenosis: Prospective comparison of CT, three-dimensional gadolinium-enhanced MR, and conventional angiography
    Randoux, B
    Marro, B
    Koskas, F
    Duyme, M
    Sahel, M
    Zouaoui, A
    Marsault, C
    RADIOLOGY, 2001, 220 (01) : 179 - 185
  • [27] A comparison of the thresholding strategies of micro-CT for periodontal bone loss: a pilot study
    Chang, P-C
    Liang, K.
    Lim, J. C.
    Chung, M-C
    Chien, L-Y
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (02)
  • [28] Analysis of subtraction methods in three-dimensional contrast-enhanced peripheral MR angiography
    Huang, YX
    Webster, CA
    Wright, GA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (05) : 541 - 550
  • [29] Three-Dimensional CT Image Reconstruction Techniques: Implementation and Comparison
    Sabah, Shafiya
    Dhou, Salam
    2019 3RD INTERNATIONAL CONFERENCE ON COMMUNICATIONS, SIGNAL PROCESSING, AND THEIR APPLICATIONS (ICCSPA), 2019,
  • [30] In-line phase contrast micro-CT reconstruction for biomedical specimens
    Fu, Jian
    Tan, Renbo
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 431 - 437