Development of rapid oral bacteria detection apparatus based on dielectrophoretic impedance measurement method

被引:66
作者
Hamada, R. [1 ,2 ]
Suehiro, J. [2 ]
Nakano, M. [2 ]
Kikutani, T. [3 ]
Konishi, K. [4 ]
机构
[1] Panason Healthcare Co Ltd, R&D Ctr, Toon, Ehime 7910395, Japan
[2] Kyushu Univ, Grad Sch Informat Sci & Elect Engn, Dept Elect & Elect Engn, Nishi Ku, Fukuoka 8190395, Japan
[3] Nippon Dent Univ Sch Life Dent, Grad Sch Life Dent, Div Clin Oral Rehabil, Chiyoda Ku, Tokyo 1028158, Japan
[4] Nippon Dent Univ Sch Life Dent Tokyo, Dept Microbiol, Chiyoda Ku, Tokyo 1028159, Japan
关键词
ASPIRATION PNEUMONIA; SELECTIVE DETECTION; ACQUIRED PNEUMONIA; ELDERLY-PATIENTS; CARE; COLONIZATION; INFECTION; CELLS; ELECTROPERMEABILIZATION; PLAQUE;
D O I
10.1049/iet-nbt.2010.0011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a bacteria detection apparatus based on dielectrophoretic impedance measurement (DEPIM) method was demonstrated for rapid evaluation of oral hygiene. The authors integrated a micro electrode chip on which bacteria were captured by dielectrophoresis (DEP), an AC voltage source to induce DEP force, and an impedance measurement circuit to a portable instrument that enables rapid and automated oral bacterial inspection in hospitals and clinics. Special considerations have been made on effects of high electrical conductivity of oral samples on DEP force and DEPIM results. It was shown experimentally and theoretically that using a higher electric field frequency for the DEP bacteria trap and the impedance measurement could realise DEPIM application to bacteria inspection from oral samples with higher conductivity. Based on these investigations, the authors optimised the frequency condition of the DEPIM suitable for inspecting an oral sample along with the design and development of a portable DEPIM apparatus for on-site inspection of oral bacteria. Under the optimised frequency condition, DEPIM results were in good agreement with the conventional culture method showing significant applicability of the DEPIM apparatus for practical rapid oral bacteria inspection.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 30 条
[1]   Tongue-coating as risk indicator for aspiration pneumonia in edentate elderly [J].
Abe, Shu ;
Ishihara, Kazuyuki ;
Adachi, Mieko ;
Okuda, Katsuji .
ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2008, 47 (02) :267-275
[2]   Professional oral care reduces influenza infection in elderly [J].
Abe, Shu ;
Ishihara, Kazuyuki ;
Adachi, Mieko ;
Sasaki, Hidetada ;
Tanaka, Kouko ;
Okuda, Katsuji .
ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2006, 43 (02) :157-164
[3]   Oral hygiene evaluation for effective oral care in preventing pneumonia in dentate elderly [J].
Abe, Shu ;
Ishihara, Kazuyuki ;
Adachi, Mieko ;
Okuda, Katsuji .
ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2006, 43 (01) :53-64
[4]   Comparison of a rapid ATP bioluminescence assay and standard plate count methods for assessing microbial contamination of consumers' refrigerators [J].
Chen, Fur-Chi ;
Godwin, Sandria L. .
JOURNAL OF FOOD PROTECTION, 2006, 69 (10) :2534-2538
[5]   Indicators of potentially drug resistant bacteria in severe nursing home acquired pneumonia [J].
El Solh, AA ;
Pietrantoni, C ;
Bhat, A ;
Bhora, M ;
Berbary, E .
CHEST, 2004, 126 (04) :845S-845S
[6]   AC electrokinetics: applications for nanotechnology [J].
Hughes, MP .
NANOTECHNOLOGY, 2000, 11 (02) :124-132
[7]   GASTRODUODENAL DYSFUNCTION AND BACTERIAL-COLONIZATION OF THE VENTILATED LUNG [J].
INGLIS, TJJ ;
SHERRATT, MJ ;
SPROAT, LJ ;
GIBSON, JS ;
HAWKEY, PM .
LANCET, 1993, 341 (8850) :911-913
[8]   Professional oral health care reduces the number of oropharyngeal bacteria [J].
Ishikawa, A. ;
Yoneyama, T. ;
Hirota, K. ;
Miyake, Y. ;
Miyatake, K. .
JOURNAL OF DENTAL RESEARCH, 2008, 87 (06) :594-598
[9]  
Jones T B, 2005, Electromechanics of particles
[10]   USE OF FLUOROCHROMES FOR DIRECT ENUMERATION OF TOTAL BACTERIA IN ENVIRONMENTAL-SAMPLES - PAST AND PRESENT [J].
KEPNER, RL ;
PRATT, JR .
MICROBIOLOGICAL REVIEWS, 1994, 58 (04) :603-615