DESIGN & RESEARCH OF INTERSPINOUS LUMBAR NON-FUSION DEVICE

被引:0
|
作者
Li, Lei [1 ]
Chang, Zhaohua [1 ]
Gu, Xuelian [1 ]
Song, Chengli [1 ]
机构
[1] Univ Shanghai Sci & Technol, Shanghai Inst Minimally Invas Therapy, Shanghai, Peoples R China
关键词
FINITE-ELEMENT-ANALYSIS; MOTION SEGMENT; STRESSES;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Long term clinical data showed that lumbar fusion for Lumbar spinal stenosis (LSS) and lumbar disc degeneration (LDD) therapy could change the loads of disc and articular facet and increase the motion of adjacent segments which lead to facet arthropathy and adjacent level degeneration. This study is to design and analyze an interspinous process device (IPD) that could prevent adjacent level degeneration in the LSS and LDD therapy. Method: The IPD was designed based on anatomical parameters measured from 3D CT images directly. The IPD was inserted at the validated finite element model of the mono-segmental L3/L4. The biomechanical performance of a pair of interbody fusion cages and a paired pedicel screws were studied to compare with the IPD. The model was loaded with the upper body weight and muscle forces to simulate five loading cases including standing, compression, flexion, extension, lateral bending and axial rotation. Results: The interbody fusion cage induced serious stress concentration on the surface of vertebral body, has the worst biomechanical performance among the three systems. Pedicle screws and interbody fusion cage could induce stress concentration within vertebral body which leads to vertebral compression fracture or screw loosening. Regarding to disc protection, the IPD had higher percentage to share the load of posterior lumbar structure than the pedicel screws and interbody fusion cage. Conclusion: IPD has the same loads as pedicle screw-rod which suggests it has a good function in the posterior stability. While the IPD had much less influence on vertebral body. Furthermore, IPD could share the load of intervertebral discs and facet joints to maintain the stability of lumbar spine.
引用
收藏
页码:17 / 18
页数:2
相关论文
共 50 条
  • [31] Biomechanics of a lumbar interspinous anchor with anterior lumbar interbody fusion Laboratory investigation
    Karahalios, Dean G.
    Kaibara, Taro
    Porter, Randall W.
    Kakarla, Udaya K.
    Reyes, Phillip M.
    Baaj, Ali A.
    Yaqoobi, Ali S.
    Crawford, Neil R.
    JOURNAL OF NEUROSURGERY-SPINE, 2010, 12 (04) : 372 - 380
  • [32] NON-FUSION APPLICATIONS FOR TERAWATT LASERS
    WILSON, J
    LASER FOCUS WITH FIBEROPTIC TECHNOLOGY, 1981, 17 (07): : 47 - 50
  • [33] Optimization of a lumbar interspinous fixation device for the lumbar spine with degenerative disc disease
    Heo, Minhyeok
    Yun, Jihwan
    Kim, Hanjong
    Lee, Sang-Soo
    Park, Seonghun
    PLOS ONE, 2022, 17 (04):
  • [34] Bibliometric analysis of interspinous device in treatment of lumbar degenerative diseases
    Hu, Yunxiang
    Yang, Rui
    Liu, Sanmao
    Wang, Hong
    MEDICINE, 2024, 103 (09) : E37351
  • [35] Biomechanical efficacy of a combined interspinous fusion system with a lumbar interbody fusion cage
    Kim, Yeong-Hyeon
    Jung, Tae-Gon
    Park, Eun-Young
    Kang, Guen-Woo
    Kim, Kyung-Ah
    Lee, Sung-Jae
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (05) : 997 - 1001
  • [36] Percutaneous Decompression of Lumbar Spinal Stenosis with a New Interspinous Device
    Salvatore Masala
    Roberto Fiori
    Dario Alberto Bartolucci
    Tommaso Volpi
    Eros Calabria
    Federica Novegno
    Giovanni Simonetti
    CardioVascular and Interventional Radiology, 2012, 35 : 368 - 374
  • [37] Biomechanical efficacy of a combined interspinous fusion system with a lumbar interbody fusion cage
    Yeong-Hyeon Kim
    Tae-Gon Jung
    Eun-Young Park
    Guen-Woo Kang
    Kyung-Ah Kim
    Sung-Jae Lee
    International Journal of Precision Engineering and Manufacturing, 2015, 16 : 997 - 1001
  • [38] COMPARISON OF RADIOGRAPHIC FINDINGS IN FUSION AND NON-FUSION PATIENTS 10 OR MORE YEARS FOLLOWING LUMBAR-DISK SURGERY
    FRYMOYER, JW
    HANLEY, EN
    HOWE, J
    KUHLMANN, D
    MATTERI, RE
    SPINE, 1979, 4 (05) : 435 - 440
  • [39] Biomechanical analysis of a new lumbar interspinous device with optimized topology
    Chen-Sheng Chen
    Shih-Liang Shih
    Medical & Biological Engineering & Computing, 2018, 56 : 1333 - 1341
  • [40] Aperius interspinous device for degenerative lumbar spinal stenosis: a review
    Ramesh, Ashwanth
    Lyons, Frank
    Kelleher, Michael
    NEUROSURGICAL REVIEW, 2016, 39 (02) : 197 - 205