DESIGN & RESEARCH OF INTERSPINOUS LUMBAR NON-FUSION DEVICE

被引:0
|
作者
Li, Lei [1 ]
Chang, Zhaohua [1 ]
Gu, Xuelian [1 ]
Song, Chengli [1 ]
机构
[1] Univ Shanghai Sci & Technol, Shanghai Inst Minimally Invas Therapy, Shanghai, Peoples R China
关键词
FINITE-ELEMENT-ANALYSIS; MOTION SEGMENT; STRESSES;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Long term clinical data showed that lumbar fusion for Lumbar spinal stenosis (LSS) and lumbar disc degeneration (LDD) therapy could change the loads of disc and articular facet and increase the motion of adjacent segments which lead to facet arthropathy and adjacent level degeneration. This study is to design and analyze an interspinous process device (IPD) that could prevent adjacent level degeneration in the LSS and LDD therapy. Method: The IPD was designed based on anatomical parameters measured from 3D CT images directly. The IPD was inserted at the validated finite element model of the mono-segmental L3/L4. The biomechanical performance of a pair of interbody fusion cages and a paired pedicel screws were studied to compare with the IPD. The model was loaded with the upper body weight and muscle forces to simulate five loading cases including standing, compression, flexion, extension, lateral bending and axial rotation. Results: The interbody fusion cage induced serious stress concentration on the surface of vertebral body, has the worst biomechanical performance among the three systems. Pedicle screws and interbody fusion cage could induce stress concentration within vertebral body which leads to vertebral compression fracture or screw loosening. Regarding to disc protection, the IPD had higher percentage to share the load of posterior lumbar structure than the pedicel screws and interbody fusion cage. Conclusion: IPD has the same loads as pedicle screw-rod which suggests it has a good function in the posterior stability. While the IPD had much less influence on vertebral body. Furthermore, IPD could share the load of intervertebral discs and facet joints to maintain the stability of lumbar spine.
引用
收藏
页码:17 / 18
页数:2
相关论文
共 50 条
  • [21] Clinical Experiences of Non-fusion Dynamic Stabilization Surgery for Adjacent Segmental Pathology after Lumbar Fusion
    Lee, Soo Eon
    Jahng, Tae-Ahn
    Kim, Hyun-Jib
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2016, 10
  • [22] Multicenter Retrospective Review of Safety and Efficacy of a Novel Minimally Invasive Lumbar Interspinous Fusion Device
    Falowski, Steven M.
    Mangal, Vipul
    Pope, Jason
    Patel, Anish
    Coleman, Mark
    Kendall, Dan
    Brouillette, Richard
    Fishman, Michael A.
    JOURNAL OF PAIN RESEARCH, 2021, 14 : 1525 - 1531
  • [23] Effectiveness of Neural Mobilisation in Postoperative Physiotherapy Following Non-Fusion Lumbar Spine Surgery
    Konrad, B.
    Thue, L.
    Robinson, H. S.
    Koch, R.
    Guenther, K. -P.
    MANUELLE THERAPIE, 2008, 12 (04) : 153 - 157
  • [24] Design of a Lumbar Interspinous Fixation Device for Minimally Invasive Surgery and Spine Motion Stabilization
    Minhyeok Heo
    Jihwan Yun
    Sang-Hu Park
    Yoon Suk Choi
    Sang-Soo Lee
    Seonghun Park
    Journal of Medical and Biological Engineering, 2020, 40 : 1 - 10
  • [25] Design of a Lumbar Interspinous Fixation Device for Minimally Invasive Surgery and Spine Motion Stabilization
    Heo, Minhyeok
    Yun, Jihwan
    Park, Sang-Hu
    Choi, Yoon Suk
    Lee, Sang-Soo
    Park, Seonghun
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2020, 40 (01) : 1 - 10
  • [26] Biomechanical comparison of an interspinous fusion device and bilateral pedicle screw system as additional fixation for lateral lumbar interbody fusion
    Doulgeris, James J.
    Aghayev, Kamran
    Gonzalez-Blohm, Sabrina A.
    Lee, William E., III
    Vrionis, Frank D.
    CLINICAL BIOMECHANICS, 2015, 30 (02) : 205 - 210
  • [27] Synovial Cyst in the Setting of an Interspinous Fusion Device
    Judy, Brendan F.
    Abou-Mrad, Tatiana
    Bydon, Ali
    WORLD NEUROSURGERY, 2023, 179 : 144 - 145
  • [28] Can the Interspinous Device, SPIRE™, be an Alternative Fixation Modality in Posterior Lumbar Fusion Instead of Pedicle Screw?
    Lee, Chang-Hyun
    Hyun, Seung-Jae
    Kim, Ki-Jeong
    Jahng, Tae-Ahn
    Kim, Hyun-Jib
    TURKISH NEUROSURGERY, 2017, 27 (03) : 408 - 413
  • [29] Non-fusion instrumentation of the lumbar spine with a hinged pedicle screw rod system: an in vitro experiment
    Werner Schmoelz
    U. Onder
    A. Martin
    A. von Strempel
    European Spine Journal, 2009, 18 : 1478 - 1485
  • [30] Non-fusion instrumentation of the lumbar spine with a hinged pedicle screw rod system: an in vitro experiment
    Schmoelz, Werner
    Onder, U.
    Martin, A.
    von Strempel, A.
    EUROPEAN SPINE JOURNAL, 2009, 18 (10) : 1478 - 1485