Serial evaluation of atrial tachyarrhythmia burden and frequency after implantation of a dual-chamber cardioverter-defibrillator

被引:1
|
作者
Schwartzman, D
Gold, M
Quesada, A
Koehler, JL
Mehra, R
Euler, DE
机构
[1] Univ Pittsburgh, Pittsburgh, PA USA
[2] Med Univ S Carolina, Charleston, SC 29425 USA
[3] Univ Valencia, Gen Hosp, Valencia, Spain
[4] Medtronic Inc, Minneapolis, MN USA
关键词
implantable cardioverter; defibrillator; atrial fibrillation; pacing; defibrillation;
D O I
10.1111/j.1540-8167.2005.40519.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We sought to characterize atrial tachyarrhythmia (AT) burden and frequency after implantation of a dual-chamber implantable cardioverter-defibrillator (D-ICD). Methods and Results: A total of 149 subjects underwent implantation of a D-ICD (Jewel AF((R)) model 7250, Medtronic, Inc.) for the primary indication of drug-resistant AT, and were followed for at least 12 months during which device programming was constant. The device employed atrial overdrive pacing as well as shocks to terminate episodes of AT. Arrhythmia burden and frequency were evaluated during the 0- to 6-month follow-up and and 6- to 12-month follow-up intervals. A majority of subjects (62%) received a type I/III antiarrhythmic drug during follow-up. The median arrhythmia burden decreased from 8.2 hours/month during 0-6 months to 3.3 hours/month during 6-12 months (P = 0.004); this result was driven primarily by the subgroup with persistent AT prior to device implantation. There was no significant change in the median AT frequency (2.2 vs 1.0 episodes/month). There was a significant decrease in the median shock frequency (0.32 vs 0.00 shocks/month, P = 0.003) and an increase in shock efficacy (85.5% vs 94.9%, P = 0.01). Conclusions: Device-based treatment of AT, in association with antiarrhythmic drugs, yields a significant time-dependent decrease in AT burden but not frequency.
引用
收藏
页码:708 / 713
页数:6
相关论文
共 50 条
  • [41] Incidence and predictors of moderate to severe tricuspid regurgitation after dual-chamber pacemaker implantation
    Cho, Min Soo
    Kim, Jun
    Lee, Jung-Bok
    Nam, Gi-Byoung
    Choi, Kee-Joon
    Kim, You-Ho
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (01): : 85 - 92
  • [42] Implantable dual-chamber defibrillator for the selective treatment of spontaneous atrial and ventricular arrhythmias:: Arrhythmia incidence and device performance
    Schuchert, A
    Boriani, G
    Wollmann, C
    Biffi, M
    Kühl, M
    Sperzel, J
    Stiller, S
    Gasparini, G
    Böcker, D
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2005, 12 (02) : 149 - 156
  • [43] Role of exercise electrocardiogram to screen for T-wave oversensing after implantation of subcutaneous implantable cardioverter-defibrillator
    Afzal, Muhammad R.
    Evenson, Christopher
    Badin, Auroa
    Patel, Dilesh
    Godara, Hemant
    Essandoh, Michael
    Okabe, Toshimasa
    Tyler, Jaret
    Houmsse, Mahmoud
    Augostini, Ralph
    Hummel, John
    Kalbfleisch, Steven
    Daoud, Emile G.
    Weiss, Raul
    HEART RHYTHM, 2017, 14 (10) : 1436 - 1439
  • [44] Randomized pilot study of a new atrial-based minimal ventricular pacing mode in dual-chamber implantable cardioverter-defibrillators
    Sweeney, MO
    Shea, JB
    Fox, V
    Adler, S
    Nelson, L
    Mullen, TJ
    Belk, P
    Casavant, D
    Sheldon, T
    HEART RHYTHM, 2004, 1 (02) : 160 - 167
  • [45] Is this pacemaker working properly? Prolongation of the atrial escape interval following activation of the ventricular safety pacing algorithm in a dual-chamber implantable cardioverter defibrillator with atrial-based, lower rate timing
    Johri, Amer M.
    Baranchuk, Adrian
    Simpson, Christopher S.
    Redfearn, Damian P.
    Abdollah, Hoshiar
    CANADIAN JOURNAL OF CARDIOLOGY, 2008, 24 (07) : E43 - E44
  • [46] Impact of Atrial Lead Position on Functional Cardiac Parameters in Patients Requiring Dual-Chamber Pacemaker Implantation
    Gharibeh, Sarah X.
    Jochmann, Valerie
    Szendey, Istvan
    Jirak, Peter
    Topf, Albert
    Ladage, Dorothee
    Hoppe, Uta C.
    Eckardt, Lars
    Chorianopoulos, Emmanuel
    Motloch, Lukas J.
    Larbig, Robert
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (07)
  • [47] Ability to remotely monitor atrial high-rate episodes using a single-chamber implantable cardioverter-defibrillator with a floating atrial sensing dipole
    Hindricks, Gerhard
    Theuns, Dominic A.
    Bar-Lev, David
    Anguera, Ignasi
    Ayala Paredes, Felix Alejandro
    Arnold, Martin
    Geller, J. Christoph
    Merkely, Bela
    Dyrda, Katia Marjolaine
    Perings, Christian
    Maglia, Giampiero
    Ploux, Sylvain
    Meyhoefer, Juergen
    Blomstroem-Lundqvist, Carina
    Karjalainen, Pasi
    Liang, Yanchun
    Diemberger, Igor
    Wranicz, Jerzy Krzysztof
    Barr, Craig
    Quartieri, Fabio
    Timmel, Tobias
    Bollmann, Andreas
    EUROPACE, 2023, 25 (05):
  • [48] Long-Term Effects of Left Bundle Branch Area Pacing Versus Traditional Right Ventricular Pacing on Atrial Fibrillation After Dual-Chamber Pacemaker Implantation
    Chen, Jieruo
    Wang, Zefeng
    Hang, Fei
    Sun, Weiping
    Li, Haiwei
    Wu, Yongquan
    CLINICAL CARDIOLOGY, 2025, 48 (03)
  • [49] Reduction of ventricular tachyarrhythmia by treatment of atrial fibrillation in ICD patients with dual-chamber implantable cardloverter/defibrillators capable of atrtal therapy delivery:: the REVERT-AF study
    Gradaus, Rainer
    Seidl, Karlheinz
    Korte, Thomas
    Himmrich, Ewald
    Wieneke, Heinrich
    Schuchert, Andreas
    Bauer, Wolfgang
    Gerss, Joachim
    Wollmann, Christian G.
    Borggrefe, Martin
    Boecker, Dirk
    EUROPACE, 2007, 9 (07): : 534 - 539
  • [50] The role of atrial sensing for new-onset atrial arrhythmias diagnosis and management in single-chamber implantable cardioverter-defibrillator recipients: Results from the THINGS registry
    Biffi, Mauro
    Iori, Matteo
    De Maria, Elia
    Bolognesi, Maria Giulia
    Placci, Angelo
    Calvi, Valeria
    Allocca, Giuseppe
    Ammendola, Ernesto
    Carinci, Valeria
    Boggian, Giulio
    Saporito, Davide
    Grassini, Diego
    Giacopelli, Daniele
    Statuto, Giovanni
    Ziacchi, Matteo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (04) : 846 - 853