Serial evaluation of atrial tachyarrhythmia burden and frequency after implantation of a dual-chamber cardioverter-defibrillator

被引:1
|
作者
Schwartzman, D
Gold, M
Quesada, A
Koehler, JL
Mehra, R
Euler, DE
机构
[1] Univ Pittsburgh, Pittsburgh, PA USA
[2] Med Univ S Carolina, Charleston, SC 29425 USA
[3] Univ Valencia, Gen Hosp, Valencia, Spain
[4] Medtronic Inc, Minneapolis, MN USA
关键词
implantable cardioverter; defibrillator; atrial fibrillation; pacing; defibrillation;
D O I
10.1111/j.1540-8167.2005.40519.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We sought to characterize atrial tachyarrhythmia (AT) burden and frequency after implantation of a dual-chamber implantable cardioverter-defibrillator (D-ICD). Methods and Results: A total of 149 subjects underwent implantation of a D-ICD (Jewel AF((R)) model 7250, Medtronic, Inc.) for the primary indication of drug-resistant AT, and were followed for at least 12 months during which device programming was constant. The device employed atrial overdrive pacing as well as shocks to terminate episodes of AT. Arrhythmia burden and frequency were evaluated during the 0- to 6-month follow-up and and 6- to 12-month follow-up intervals. A majority of subjects (62%) received a type I/III antiarrhythmic drug during follow-up. The median arrhythmia burden decreased from 8.2 hours/month during 0-6 months to 3.3 hours/month during 6-12 months (P = 0.004); this result was driven primarily by the subgroup with persistent AT prior to device implantation. There was no significant change in the median AT frequency (2.2 vs 1.0 episodes/month). There was a significant decrease in the median shock frequency (0.32 vs 0.00 shocks/month, P = 0.003) and an increase in shock efficacy (85.5% vs 94.9%, P = 0.01). Conclusions: Device-based treatment of AT, in association with antiarrhythmic drugs, yields a significant time-dependent decrease in AT burden but not frequency.
引用
收藏
页码:708 / 713
页数:6
相关论文
共 50 条
  • [21] Efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter defibrillator
    Adler, SW
    Wolpert, C
    Warman, EN
    Musley, SK
    Koehler, JL
    Euler, DE
    CIRCULATION, 2001, 104 (08) : 887 - 892
  • [22] Juxtaposition of Automatic Mode Switching and Tachycardia-Terminating Algorithms in a Dual-Chamber Implantable Cardioverter Defibrillator
    Barold, S. Serge
    Stroobandt, Roland X.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (10): : 1408 - 1411
  • [23] Olmesartan Reduces New-onset Atrial Fibrillation and Atrial Fibrillation Burden after Dual-chamber Pacemaker Implantation in Atrioventricular Block Patients
    Zhang, Hang
    Pan, Chang
    Zhang, Juan
    Zhu, Lin-Lin
    Huang, Kai
    Zhong, Yun
    Hu, Zuo-Ying
    CHINESE MEDICAL JOURNAL, 2016, 129 (18) : 2143 - 2148
  • [24] Outcome after implantation of a cardioverter-defibrillator in patients with Brugada syndrome -: A multicenter study
    Sacher, Frederic
    Probst, Vincent
    Iesaka, Yoshito
    Jacon, Peggy
    Laborderie, Julien
    Mizon-Gerard, Frederique
    Mabo, Philippe
    Reuter, Sylvain
    Lamaison, Dominique
    Takahashi, Yoshihide
    O'Neill, Mark D.
    Garrigue, Stephane
    Pierre, Bertrand
    Jais, Pierre
    Pasquie, Jean-Luc
    Hocini, Meleze
    Salvador-Mazenq, Michele
    Nogami, Akihiko
    Amiel, Alain
    Defaye, Pascal
    Bordachar, Pierre
    Boveda, Serge
    Maury, Philippe
    Klug, Didier
    Babuty, Dominique
    Haissaguerre, Michel
    Mansourati, Jacques
    Clementy, Jacques
    Le Marec, Herve
    CIRCULATION, 2006, 114 (22) : 2317 - 2324
  • [25] Underrecognizedentity of the transient rise in the atrial capture threshold early after dual-chamber pacemaker implantation
    Uehara, Yoshiko
    Yoshida, Kentaro
    Kimata, Akira
    Ogawa, Kojiro
    Abe, Daisuke
    Tsumagari, Yasuaki
    Tsuneoka, Hidekazu
    Yui, Yoshiaki
    Ito, Yoko
    Ebine, Mari
    Takeyasu, Noriyuki
    Aonuma, Kazutaka
    Nogami, Akihiko
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (12): : 1396 - 1404
  • [26] Risk and predictors of mortality after implantable cardioverter-defibrillator implantation in patients with sarcoid cardiomyopathy
    Higgins, Angela Y.
    Annapureddy, Amarnath R.
    Wang, Yongfei
    Minges, Karl E.
    Bellumkonda, Lavanya
    Lampert, Rachel
    Rosenfeld, Lynda E.
    Jacoby, Daniel L.
    Curtis, Jeptha P.
    Miller, Edward J.
    Freeman, James, V
    AMERICAN HEART JOURNAL, 2022, 246 : 21 - 31
  • [27] Reduction in electrocardiographic lateral precordial voltage after subcutaneous implantable cardioverter-defibrillator implantation
    Liang, Jackson J.
    Maeda, Shingo
    Supple, Gregory E.
    ACTA CARDIOLOGICA, 2017, 72 (02) : 221 - 222
  • [28] Clinical experience with tiered atrial therapies and atrial arrhythmia prevention algorithms in a dual chamber cardioverter defibrillator
    Daoud, Emile G.
    Nademanee, Koonlawee
    Fuenzalida, Charles
    Tomassoni, Gery F.
    Schuger, Claudio
    Chisner, Michael
    Simones, Melissa
    Schwartz, Mark
    Reeve, Helen
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (08) : 852 - 856
  • [29] Incidence of atrial high rate episodes after dual-chamber permanent pacemaker implantation and its clinical predictors
    Samuel, Jeffry
    Batta, Akash
    Barwad, Parag
    Sharma, Yash Paul
    Panda, Prashant
    Kaur, Navjyot
    Shrimanth, Y. S.
    Pruthvi, C. R.
    Sambyal, Bharat
    INDIAN HEART JOURNAL, 2022, 74 (06) : 500 - 504
  • [30] Early Increased Physical Activity, Cardiac Rehabilitation, and Survival After Implantable Cardioverter-Defibrillator Implantation
    Atwater, Brett D.
    Li, Zhen
    Pritchard, Jessica
    Greiner, Melissa A.
    Nabutovsky, Yelena
    Hammill, Bradley G.
    CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2021, 14 (08): : E007580