Radiopacity and Porosity of Bulk-fill and Conventional Composite Posterior Restorations-Digital X-ray Analysis

被引:27
作者
Soares, C. J. [1 ]
Rosatto, C. M. P. [1 ]
Carvalho, V. F. [1 ]
Bicalho, A. A. [1 ]
Henriques, J. C. G. [2 ]
Faria-e-Silva, A. L. [3 ]
机构
[1] Univ Fed Uberlandia, Dept Operat Dent & Dent Mat, Dent Sch, Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Dent Sch, Dept Radiol & Stomatol, Uberlandia, MG, Brazil
[3] Univ Fed Sergipe, Dent Sch, Dept Operat Dent, Aracaju, Sergipe, Brazil
关键词
RESIN COMPOSITES; MARGINAL ADAPTATION; DENTAL MATERIALS; SYSTEMS; RADIODENSITY; METAANALYSIS; RADIOGRAPHY;
D O I
10.2341/16-146-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare radiopacity and porosity as expressed by the presence of voids in restorations carried out using bulk-fill and incremental filling techniques to restore large mesio-occlusal-distal (MOD) cavities. Methods: Fifty-five molars with MOD preparations were incrementally filled with Filtek Z-350XT (Z350XT) or bulk-fill composite: Filtek Bulk Fill/Z-350XT (FBF/Z350XT), Venus Bulk Fill/Charisma Diamond (VBF/CHA), SDR/Es-thet-X HD (SDR/EST-X), Tetric EvoCeram Bulk Fill (TEC). Digital radiographic images (Vista-scan scanner) were taken of restored molars and analyzed at the gingival and isthmus floors. Radiodensity measurements were performed using standardized points symmetrically distributed over each region of composite and tooth structure. Three calibrated evaluators visually assessed the presence of voids. Confidence intervals were calculated, and data were analyzed using analysis of variance and chi(2) tests. Results: TEC and VBF/CHA showed significantly higher radiodensities, while the lowest values were observed for FBF/Z350XT and Z350XT. Radiodensity at the cervical regions tended to be greater than that found at the isthmus floor. The lowest incidence of voids was found for VBF/CHA, whereas the incremental insertion technique resulted in the highest rate of voids. Conclusion: Bulk-fill composite resin demonstrated an adequate level of radiodensity and a reduced presence of voids compared with the incremental filling technique.
引用
收藏
页码:616 / 625
页数:10
相关论文
共 26 条
  • [1] Bicalho A, 2014, OPER DENT, V39, P83, DOI DOI 10.2341/12-442-L
  • [2] Bicalho AA., 2014, Operative Dentistry, DOI [10.2341/12-441-L, DOI 10.2341/12-441-L]
  • [3] Bouschlicher MR, 1999, OPER DENT, V24, P20
  • [4] Detecting Secondary Caries Lesions: A Systematic Review and Meta-analysis
    Brouwer, F.
    Askar, H.
    Paris, S.
    Schwendicke, F.
    [J]. JOURNAL OF DENTAL RESEARCH, 2016, 95 (02) : 143 - 151
  • [5] Marginal adaptation of class II cavities restored with bulk-fill composites
    Campos, Edson Alves
    Ardu, Stefano
    Lefever, Dorien
    Jasse, Fernanda Ferreira
    Bortolotto, Tissiana
    Krejci, Ivo
    [J]. JOURNAL OF DENTISTRY, 2014, 42 (05) : 575 - 581
  • [6] Comparative Radiopacity of Six Flowable Resin Composites
    Ergucu, Z.
    Turkun, L. S.
    Onem, E.
    Guneri, P.
    [J]. OPERATIVE DENTISTRY, 2010, 35 (04) : 436 - 440
  • [7] Farman T T, 1996, Gen Dent, V44, P532
  • [8] Radiodensity of base, liner and luting dental materials
    Fonseca, Rodrigo Borges
    Branco, Carolina Assaf
    Soares, Paulo Vinicius
    Correr-Sobrinho, Louren O.
    Haiter-Neto, Francisco
    Fernandes-Neto, Alfredo Julio
    Soares, Carlos Jose
    [J]. CLINICAL ORAL INVESTIGATIONS, 2006, 10 (02) : 114 - 118
  • [9] Monomer conversion, microhardness, internal marginal adaptation, and shrinkage stress of bulk-fill resin composites
    Fronza, Bruna Marin
    Rueggeberg, Frederick Allen
    Braga, Roberto Ruggiero
    Mogilevych, Borys
    Silva Soares, Luis Eduardo
    Martin, Airton Abrahao
    Ambrosano, Glaucia
    Giannini, Marcelo
    [J]. DENTAL MATERIALS, 2015, 31 (12) : 1542 - 1551
  • [10] Radiopacity of dental materials using a digital X-ray system
    Gu, Steven
    Rasimick, Brian J.
    Deutsch, Allan S.
    Musikant, Barry Lee
    [J]. DENTAL MATERIALS, 2006, 22 (08) : 765 - 770