共 23 条
Carboxymethyl-botryosphaeran stabilized carbon nanotubes aqueous dispersion: A new platform design for electrochemical sensing of desloratadine
被引:8
|作者:
Salamanca-Neto, Carlos A. R.
[1
]
Olean-Oliveira, Andre
[2
]
Scremin, Jessica
[1
]
Ceravolo, Graziela S.
[3
]
Dekker, Robert F. H.
[4
]
Barbosa-Dekker, Aneli M.
[5
]
Teixeira, Marcos F. S.
[2
]
Sartori, Elen R.
[1
]
机构:
[1] Univ Estadual Londrina, Ctr Ciencias Exatas, Dept Quim, Lab Eletroanalit & Sensores, BR-86057970 Londrina, PR, Brazil
[2] Univ Estadual Paulista UNESP, Fac Ciencias & Tecnol, Dept Quim & Bioquim, Presidents Prudente, SP, Brazil
[3] Univ Estadual Londrina, Ctr Ciencias Biol, Dept Fisiol, BR-86057970 Londrina, PR, Brazil
[4] Univ Tecnol Fed Parana, Programa Posgrad Engn Ambiental, Campus Londrina, BR-86036370 Londrina, PR, Brazil
[5] Univ Estadual Londrina, Ctr Ciencias Exatas, Dept Quim, BR-86057970 Londrina, PR, Brazil
来源:
关键词:
Botryosphaeria rhodina MAMB-05;
MWCNTs aqueous dispersion;
Modified glassy carbon electrode;
Pharmaceutical analysis;
Biological sample;
BORON-DOPED DIAMOND;
VOLTAMMETRIC DETERMINATION;
CHEMICAL-MODIFICATION;
MODIFIED ELECTRODE;
BEHAVIOR;
FILM;
LORATADINE;
GRAPHITE;
WATER;
D O I:
10.1016/j.talanta.2019.120642
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
The polysaccharide carboxymethyl-botryosphaeran (CMB) was used to improve the dispersion of multi-walled carbon nanotubes (MWCNTs) in water. This feature was applied in modifying a glassy carbon electrode (GCE) to construct a sensitive voltammetric sensor for the determination of desloratadine (DESL), a tricyclic antihistamine. The morphology and spectroscopic behavior of the sensor were evaluated. The modified sensor was characterized as homogeneous, and presented a higher electroactive area and a lower charge transfer resistance compared to the unmodified GCE. Using linear sweep voltammetry at 25 mV s(-1), the developed sensor presented a sensitivity of 1.018 mu A L mu mol(-1) in the linear working range of 1.99-32.9 mu mol L-1, with a detection limit of 0.88 mu mol L-1 of DESL in 0.10 mol L-1 potassium hydrogen-phosphate solution (pH 8.0). In addition, the sensor showed excellent repeatability with a relative standard deviation of only 1.02% for a sequence of 10 measurements. The sensor was successfully applied in the analysis of pharmaceutical preparations containing DESL, with equivalent results compared to a validated spectrophotometric method at the 95% confidence level. The sensor was also employed in the analysis of a spiked sample of DESL in rat serum.
引用
收藏
页数:8
相关论文