A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia

被引:393
作者
Osman, Reham B. [1 ,2 ]
Swain, Michael V. [3 ]
机构
[1] Acad Ctr Dent Amsterdam ACTA, Dept Oral Implantol & Prosthet Dent, NL-1081 LA Amsterdam, Netherlands
[2] Cairo Univ, Dept Removable Prosthodont, Giza 11553, Egypt
[3] Univ Sydney, Sydney Dent Hosp, Biomat Lab, Surry Hills, NSW 2010, Australia
关键词
SURFACE-MODIFIED ZIRCONIA; MECHANICAL-PROPERTIES; ORAL IMPLANTS; IN-VITRO; FRACTURE-TOUGHNESS; MOLAR REPLACEMENT; 2-PIECE ZIRCONIA; TISSUE-RESPONSE; BONE-FORMATION; HEAT-TREATMENT;
D O I
10.3390/ma8030932
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The goal of the current publication is to provide a comprehensive literature review on the topic of dental implant materials. The following paper focuses on conventional titanium implants and more recently introduced and increasingly popular zirconia implants. Major subtopics include the material science and the clinical considerations involving both implant materials and the influence of their physical properties on the treatment outcome. Titanium remains the gold standard for the fabrication of oral implants, even though sensitivity does occur, though its clinical relevance is not yet clear. Zirconia implants may prove to be promising in the future; however, further in vitro and well-designed in vivo clinical studies are needed before such a recommendation can be made. Special considerations and technical experience are needed when dealing with zirconia implants to minimize the incidence of mechanical failure.
引用
收藏
页码:932 / 958
页数:27
相关论文
共 152 条
[1]   Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams [J].
Abduo, Jaafar ;
Lyons, Karl ;
Bennamoun, Mohammed .
INTERNATIONAL JOURNAL OF DENTISTRY, 2014, 2014
[2]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[3]   Comparison between freestanding and tooth-connected partially stabilized zirconia implants after two years' function in monkeys: A clinical and histologic study [J].
Akagawa, Y ;
Hosokawa, R ;
Sato, Y ;
Kamayama, K .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 80 (05) :551-558
[4]   INTERFACE HISTOLOGY OF UNLOADED AND EARLY LOADED PARTIALLY-STABILIZED ZIRCONIA ENDOSSEOUS IMPLANT IN INITIAL BONE HEALING [J].
AKAGAWA, Y ;
ICHIKAWA, Y ;
NIKAI, H ;
TSURU, H .
JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (06) :599-604
[5]   Biofilm formation and composition on different implant materials in vivo [J].
Al-Ahmad, A. ;
Wiedmann-Al-Ahmad, M. ;
Faust, J. ;
Baechle, M. ;
Follo, M. ;
Wolkewitz, M. ;
Hannig, C. ;
Hellwig, E. ;
Carvalho, C. ;
Kohal, R. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 95B (01) :101-109
[6]   Osteointegration of bioactive glass-coated and uncoated zirconia in osteopenic bone:: An in vivo experimental study [J].
Aldini, NN ;
Fini, M ;
Giavaresi, G ;
Martini, L ;
Dubini, B ;
Bossi, MGP ;
Rustichelli, F ;
Krajewski, A ;
Ravaglioli, A ;
Mazzocchi, M ;
Giardino, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 68A (02) :264-272
[7]   Influence of Low-Temperature Environmental Exposure on the Mechanical Properties and Structural Stability of Dental Zirconia [J].
Alghazzawi, Tariq F. ;
Lemons, Jack ;
Liu, Perng-Ru ;
Essig, Milton E. ;
Bartolucci, Alfred A. ;
Janowski, Gregg M. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (05) :363-369
[8]  
[Anonymous], 2009, Eur. Cells Mater.
[9]   ZrO2 three-unit fixed partial dentures:: comparison of failure load before and after exposure to a mastication simulator [J].
Att, W. ;
Grigoriadou, M. ;
Strub, J. R. .
JOURNAL OF ORAL REHABILITATION, 2007, 34 (04) :282-290
[10]  
Aydin Cemal, 2010, N Y State Dent J, V76, P30