Round robin test: Wear of nine dental restorative materials in six different wear simulators - Supplement to the round robin test of 2005

被引:39
|
作者
Heintze, S. D. [1 ]
Barkmeier, W. W. [2 ]
Latta, M. A. [2 ]
Rousson, V. [3 ]
机构
[1] Ivoclar Vivadent AG, R&D, FL-9494 Schaan, Liechtenstein
[2] Creighton Univ, Sch Dent, Dept Gen Dent, Omaha, NE 68178 USA
[3] Univ Lausanne, Biostat Unit, Inst Social & Prevent Med, CH-1015 Lausanne, Switzerland
关键词
Wear; Round robin test; In vitro; Composite; Ceramic; Amalgam; Wear simulator; IN-VITRO WEAR; COMPOSITE WEAR; CLINICAL WEAR; RESIN COMPOSITES; AMALGAM; DEVICE;
D O I
10.1016/j.dental.2010.09.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The purpose of the present study was to submit the same materials that were tested in the round robin wear test of 2002/2003 to the Alabama wear method. Methods. Nine restorative materials, seven composites (belleGlass, Chromasit, Estenia, Heliomolar, SureFil, Targis, Tetric Ceram) an amalgam(Amalcap) and a ceramic (IPS Empress) have been submitted to the Alabama wear method for localized and generalized wear. The test centre did not know which brand they were testing. Both volumetric and vertical loss had been determined with an optical sensor. After completion of the wear test, the raw data were sent to IVOCLAR for further analysis. The statistical analysis of the data included logarithmic transformation of the data, the calculation of relative ranks of each material within each test centre, measures of agreement between methods, the discrimination power and coefficient of variation of each method as well as measures of the consistency and global performance for each material. Results. Relative ranks of the materials varied tremendously between the test centres. When all materials were taken into account and the test methods compared with each other, only ACTA agreed reasonably well with two other methods, i.e. OHSU and ZURICH. On the other hand, MUNICH did not agree with the other methods at all. The ZURICH method showed the lowest discrimination power, ACTA, IVOCLAR and ALABAMA localized the highest. Material-wise, the best global performance was achieved by the leucite reinforced ceramic material Empress, which was clearly ahead of belleGlass, SureFil and Estenia. In contrast, Heliomolar, Tetric Ceram and especially Chromasit demonstrated a poor global performance. The best consistency was achieved by SureFil, Tetric Ceram and Chromasit, whereas the consistency of Amalcap and Heliomolar was poor. When comparing the laboratory data with clinical data, a significant agreement was found for the IVOCLAR and ALABAMA generalized wear method. Significance. As the different wear simulator settings measure different wear mechanisms, it seems reasonable to combine at least two different wear settings to assess the wear resistance of a new material. (C) 2010 Published by Elsevier Ltd on behalf of Academy of Dental Materials. All rights reserved.
引用
收藏
页码:E1 / E9
页数:9
相关论文
共 50 条
  • [31] User Impact as an Uncertainty in Hygrothermal Simulations: Insights from a Round Robin Test
    Dang, Xinyuan
    Janssen, Hans
    Roels, Staf
    MULTIPHYSICS AND MULTISCALE BUILDING PHYSICS, IBPC 2024, VOL 1, 2025, 552 : 68 - 75
  • [32] Evaluation of the Data Quality from a Round-Robin Test of Hyperspectral Imaging Systems
    Pillay, Ruven
    Picollo, Marcello
    Hardeberg, Jon Yngve
    George, Sony
    SENSORS, 2020, 20 (14) : 1 - 26
  • [33] Statistical reliability assessment of UT round-robin test data for piping welds
    Kim, HM
    Park, IK
    Park, US
    Park, YW
    Kang, SC
    Lee, JH
    ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 1743 - 1748
  • [34] Evaluation for Standardization of 1H Quantitative NMR Spectroscopy by Round Robin Test
    Miura, Toru
    Sugimoto, Naoki
    Watanabe, Ryuichi
    Suematsu, Takako
    Takayanagi, Yoichiro
    Ito, Yoshinobu
    Saito, Naoki
    Sawa, Ryuichi
    Kato, Tsuyoshi
    Fujimine, Yoshinori
    Koike, Ryo
    Ohfuku, Yuko
    Yamada, Yuko
    Utsumi, Hiroaki
    Suzuki, Toshiyuki
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2017, 137 (12): : 1543 - 1553
  • [35] Application of a novel reference material in an international round robin test on material emissions testing
    Horn, W.
    Richter, M.
    Nohr, M.
    Wilke, O.
    Jann, O.
    INDOOR AIR, 2018, 28 (01) : 181 - 187
  • [36] 1st international round robin test on safety characteristics of hybrid mixtures
    Spitzer, Stefan H.
    Askar, Enis
    Benke, Alexander
    Cloney, Chris
    D'Hyon, Sebastian
    Dufaud, Olivier
    Dyduch, Zdzislaw
    Gabel, Dieter
    Geoerg, Paul
    Heilmann, Vanessa
    Jankuj, Vojtech
    Jian, Wang
    Krause, Ulrich
    Krietsch, Arne
    Mynarz, Miroslav
    Norman, Frederik
    Skrinsky, Jan
    Taveau, Jerome
    Vignes, Alexis
    Zakel, Sabine
    Zhong, Shengjun
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2023, 81
  • [37] Round robin test on the determination of residual stress depth distributions by X-ray diffraction
    Gibmeier, J
    Lu, J
    Scholtes, B
    ECRS 6: PROCEEDINGS OF THE 6TH EUROPEAN CONFERENCE ON RESIDUAL STRESSES, 2002, 404-7 : 659 - 664
  • [38] Conduction of a round-robin test on a real sample for the identification of gunshot residues by SEM/EDX
    Charles, Sebastien
    Dodier, Thierry
    Kaindl, Monika
    Kasteropoulos, Alain
    Knijnenberg, Alwin
    Larsson, Marcus
    Lauper, Sandrine
    Merat, Nadine
    Niewoehner, Ludwig
    Scholz, Thomas
    Simon, Laurence
    FORENSIC SCIENCE INTERNATIONAL, 2020, 309
  • [39] ROUND-ROBIN TEST ON A DIELECTRIC RESONATOR METHOD FOR MEASURING COMPLEX PERMITTIVITY AT MICROWAVE FREQUENCY
    KOBAYASHI, Y
    TAMURA, H
    IEICE TRANSACTIONS ON ELECTRONICS, 1994, E77C (06) : 882 - 887
  • [40] A Round Robin Test exercise on hydrogen absorption/desorption properties of a magnesium hydride based material
    Moretto, P.
    Zlotea, C.
    Dolci, F.
    Amieiro, A.
    Bobet, J. -L.
    Borgschulte, A.
    Chandra, D.
    Enoki, H.
    De Rango, P.
    Fruchart, D.
    Jepsen, J.
    Latroche, M.
    Jansa, I. Llamas
    Moser, D.
    Sartori, S.
    Wang, S. M.
    Zan, J. A.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (16) : 6704 - 6717