Online sample clean-up and enrichment of proteins from salty media with dynamic double gradients on a paper fluidic channel

被引:20
作者
Cai, Yu [1 ]
Niu, Ji-Cheng [1 ]
Liu, Yu-Qi [1 ]
Du, Xin-Li [2 ]
Wu, Zhi-Yong [1 ]
机构
[1] Northeastern Univ, Coll Sci, Res Ctr Analyt Sci, Chem Dept, Shenyang 110819, Peoples R China
[2] Liaoning Diabet Treatment Ctr, Shenyang 110015, Peoples R China
基金
中国国家自然科学基金;
关键词
Paper fluidic channel; Electric field gradient; pH gradient; Sample clean-up; Enrichment; Microalbuminuria; URINARY ALBUMIN EXCRETION; ELECTROKINETIC STACKING; MICROFLUIDIC DEVICES; DNA; AMPLIFICATION; MICROALBUMINURIA; IMMUNONEPHELOMETRY; PERFORMANCE; ANALYTES;
D O I
10.1016/j.aca.2019.11.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Paper-based analytical device (PAD) has received more and more attention in the field of point-of-care test (POCT) due to its low cost, portability and simple operation. Sensitivity and selectivity are two important aspects in clinical diagnostic analysis. However, low sensitivity of a PAD limits its wider application for POCT. Here we introduced a PAD that can clean and enrich the protein content from salty media with both electric field (E) and pH gradient (double E/pH gradients), with which 100-fold enrichment effect could be achieved within 70 s as demonstrated by fluorescein isothiocyanate labeled bovine serum albumin (FITC-BSA) from artificial urine media. With post staining of the protein stacking band with bromophenol blue (BPB), selective colorimetric detection of human serum albumin (HSA) was achieved simply with smartphone camera in the clinically significant range of 10-300 mg.L-1 (R-2 = 0.99) with a limit of detection (LOD) of 4.9 mg.L-1. Detection of microalbuminuria (MAU) of diabetic patients was demonstrated with this method without difference (alpha = 0.01) to that by the clinical method (immunoturbidimetry). This work demonstrated the potential of this PAD method in online sample pretreatment and detection of target component from complex physiological samples. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 45 条
[31]   Two Orders of Magnitude Improvement in Detection Limit of Lateral Flow Assays Using lsotachophoresis [J].
Moghadam, Babak Y. ;
Connelly, Kelly T. ;
Posner, Jonathan D. .
ANALYTICAL CHEMISTRY, 2015, 87 (02) :1009-1017
[32]   Isotachophoretic Preconcenetration on Paper-Based Microfluidic Devices [J].
Moghadam, Babak Y. ;
Connelly, Kelly T. ;
Posner, Jonathan D. .
ANALYTICAL CHEMISTRY, 2014, 86 (12) :5829-5837
[33]   Electrophoretic separations on paper: Past, present, and future-A review [J].
Nanthasurasak, Pavisara ;
Cabot, Joan Marc ;
See, Hong Heng ;
Guijt, Rosanne M. ;
Breadmore, Michael C. .
ANALYTICA CHIMICA ACTA, 2017, 985 :7-23
[34]   Performance characteristics of an HPLC assay for urinary albumin [J].
Owen, WE ;
Roberts, WL .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2005, 124 (02) :219-225
[35]   Amplification-free detection of DNA in a paper-based microfluidic device using electroosmotically balanced isotachophoresis [J].
Rosenfeld, Tally ;
Bercovici, Moran .
LAB ON A CHIP, 2018, 18 (06) :861-868
[36]   1000-fold sample focusing on paper-based microfluidic devices [J].
Rosenfeld, Tally ;
Bercovici, Moran .
LAB ON A CHIP, 2014, 14 (23) :4465-4474
[37]  
SCHOSINSKY KH, 1987, CLIN CHEM, V33, P223
[38]   Performance of electrokinetic stacking enhanced paper-based analytical device with smartphone for fast detection of fluorescent whitening agent [J].
Song, Yi-Zhen ;
Zhang, Xiu-Xiu ;
Ma, Biao ;
Wu, Zhi-Yong ;
Zhang, Zi-Qiang .
ANALYTICA CHIMICA ACTA, 2017, 995 :85-90
[39]  
VIBERTI GC, 1982, LANCET, V1, P1430
[40]   Paper Spray for Direct Analysis of Complex Mixtures Using Mass Spectrometry [J].
Wang, He ;
Liu, Jiangjiang ;
Cooks, R. Graham ;
Ouyang, Zheng .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (05) :877-880