Improved Results in Closed Reduction of Zygomatic Arch Fractures by the Use of Intraoperative Cone-Beam Computed Tomography Imaging

被引:7
|
作者
Johner, Jean-Pierre [1 ]
Wiedemeier, Daniel [2 ]
Hingsammer, Lukas [1 ]
Gander, Thomas [1 ]
Blumer, Michael [1 ]
Wagner, Maximilian E. H. [1 ]
机构
[1] Univ Hosp Zurich, Dept Craniomaxillofacial Surg, Zurich, Switzerland
[2] Univ Zurich, Dept Stat Serv, Div Data Anal & Stat, Zurich, Switzerland
关键词
C-ARM; ULTRASONOGRAPHY; CLASSIFICATION;
D O I
10.1016/j.joms.2019.10.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The use of intraoperative imaging could help overcome the insufficiency of closed reduction that can result from the absence of visible feedback to evaluate the accuracy of the reduction in isolated zygomatic arch fractures. The aim of the present study was to evaluate the use of intraoperative 3-dimensional cone-beam computed tomography (CBCT) to improve the accuracy of reduction, by measuring the remaining cortical step and dislocation angle. We also evaluated the effect of CBCT on the need for repeat surgery. Patients and Methods: We performed a retrospective cohort study of patients who had undergone zygomatic arch reduction surgery from January 2008 to May 2018. The patients were grouped according to the predictor variables into group A (postoperative radiologic follow-up studies) and group B (intraoperative CBCT imaging studies). The primary outcome variables were the remaining cortical step and dislocation angle compared with the ideal virtually mirrored position. These were assessed as measures of reduction accuracy. The secondary variables included age, gender, surgery duration, and fracture type. Statistical analysis was performed using a robust multiple regression analysis. Results: The 45 patients were divided into 2 subgroups with 18 patients in the no intraoperative imaging (control) group and 27 patients in the intraoperative imaging group. Insufficient reduction occurred in 1 patient in the group without intraoperative imaging, leading to repeat surgery No repeat surgery was necessary in the intraoperative imaging group. The remaining cortical step of the intraoperative imaging group was significantly lower than that of the control group (0.18 vs 2.03 mm; P < .001). For the remaining dislocation angle, similar findings were observed but without statistical significance (3.93 degrees vs 7.75 degrees; P = .58). Conclusions: The use of intraoperative CBCT significantly increased the accuracy of the reduction. Furthermore, the need for repeat surgery was not required for any patient in the intraoperative imaging group with CBCT-guided reduction. (C) 2019 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:414 / 422
页数:9
相关论文
共 50 条
  • [1] Impact of intraoperative cone beam computed tomography in the management of zygomatic fractures
    Pons, Melanie
    Lutz, Jean-Christophe
    Chatelain, Brice
    Weber, Elise
    Barrabe, Aude
    Meyer, Christophe
    Sigaux, Nicolas
    Louvrier, Aurelien
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : 349 - 354
  • [2] Intraoperative Cone-Beam Computed Tomography for open reduction and internal fixation of condylar head fractures
    Bertin, Eugenie
    Meyer, Christophe
    Louvrier, Aurelien
    Weber, Elise
    Barrabe, Aude
    Pons, Melanie
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2022, 123 (05) : E593 - E597
  • [3] Cone-beam computed tomography imaging of dentoalveolar and mandibular fractures
    Aydin, Ulkem
    Gormez, Ozlem
    Yildirim, Derya
    ORAL RADIOLOGY, 2020, 36 (03) : 217 - 224
  • [4] Cone-beam computed tomography imaging of dentoalveolar and mandibular fractures
    Ulkem Aydin
    Ozlem Gormez
    Derya Yildirim
    Oral Radiology, 2020, 36 : 217 - 224
  • [5] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Niccolò Faccioli
    Giovanni Foti
    Marco Barillari
    Andrea Atzei
    Roberto Pozzi Mucelli
    Skeletal Radiology, 2010, 39 : 1087 - 1095
  • [6] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Faccioli, Niccolo
    Foti, Giovanni
    Barillari, Marco
    Atzei, Andrea
    Mucelli, Roberto Pozzi
    SKELETAL RADIOLOGY, 2010, 39 (11) : 1087 - 1095
  • [7] Intraoperative Endodontic Applications of Cone-Beam Computed Tomography
    Ball, Randy L.
    Barbizam, Joao V.
    Cohenca, Nestor
    JOURNAL OF ENDODONTICS, 2013, 39 (04) : 548 - 557
  • [8] Intraoperative Use of Cone-Beam Computed Tomography in the Treatment of Atlantoaxial Rotatory Subluxation
    Maes, Honorine
    Janssen, Alexander
    De Muynck, Stijn
    Vantomme, Nikolaas
    WORLD NEUROSURGERY, 2020, 140 : 76 - 78
  • [9] Intraoperative use of cone-beam computed tomography in a cadaveric ossified cochlea model
    Barker, Emma
    Trimble, Keith
    Chan, Harley
    Ramsden, James
    Nithiananthan, Sajendra
    James, Adrian
    Bachar, Gideon
    Daly, Mike
    Irish, Jonathan
    Siewerdsen, Jeff
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2009, 140 (05) : 697 - 702
  • [10] Use of cone-beam computed tomography for advanced imaging of the equine patient
    Stewart, Holly L.
    Siewerdsen, Jeffery H.
    Nelson, Brad B.
    Kawcak, Christopher E.
    EQUINE VETERINARY JOURNAL, 2021, 53 (05) : 872 - 885