Modification of the Heidelberg Retinal Flowmeter to record pattern and flicker induced blood flow changes

被引:6
|
作者
Schmeisser, ET
Harrison, JM
Sutter, EE
Kiel, J
Elliott, WR
Sponsel, WE
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Ophthalmol, San Antonio, TX 78284 USA
[2] Smith Kettlewell Inst Visual Sci, San Antonio, TX USA
[3] Veridian Inc, San Antonio, TX USA
关键词
retina; flowmetry; circulation; visual stimulation;
D O I
10.1023/A:1022973315359
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We tested a prototype stimulator interfaced with a commercially available scanning laser ophthalmoscope designed to measure retinal capillary perfusion (Heidelberg Retina Flowmeter (HRF)). The add-on stimulator optically superimposed the image of a monitor display on to the subject's retina coaxially with the imaging optics of the HRF. The purpose of the study was to determine if flicker and pattern stimulation presented in this manner could evoke changes in retinal perfusion that could be measured by the HRF. Methods: The prototype stimulator projected 55degrees visual angle circular fields of homogeneous flicker, alternating checkerboard, and multi-focal m-sequence hexagonal patterns on the retina of 10 human subjects during acquisition of images by the HRF. Results: Images were successfully acquired and processed. HRF perfusion values during flicker and pattern stimulation were not significantly different from control values. Conclusions: Results of the present study and a previously published study showing a flicker-induced increase in the HRF perfusion values are contradictory. Retinal perfusion measured by the HRF were not affected by flicker and pattern stimulation delivered through the prototype device. These data are not consistent with a large flicker or pattern induced increase in retinal perfusion. The instrumental modification appears promising. However, the raster scan stimulation technique or some other aspect of stimulation or image acquisition may account for the different results in the present study and previous studies in our laboratory and in the laboratories of other investigators.
引用
收藏
页码:257 / 263
页数:7
相关论文
共 50 条
  • [41] The effect of image alignment on capillary blood flow measurement of the neuroretinal rim using the Heidelberg retina flowmeter
    Sehi, M
    Flanagan, JG
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (02) : 204 - 206
  • [42] Retinal blood flow in the normal human eye using the canon laser blood flowmeter.
    Garcia, JS
    Garcia, PT
    Rosen, RB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S82 - S82
  • [43] Heidelberg retinal flowmetry: The effect of angle of incidence on blood flow measurement.
    Kagemann, LE
    Harris, A
    Cantor, LB
    Martin, BJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1217 - 1217
  • [44] Evaluation of retinal blood flow using the Heidelberg Retina Flowmeter and nerve fiber layer thickness using Optical Coherence Tomography in a glaucomatous monkey model.
    Ghanta, RK
    Harris, A
    Hertzmark, E
    Pakter, H
    Simpson, J
    Guedes, VRF
    Drexler, W
    Fujimoto, JG
    Kagemann, L
    Schuman, JS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S15 - S15
  • [45] Diffuse luminance flicker increases blood flow in major retinal arteries and veins
    Garhöfer, G
    Zawinka, C
    Resch, H
    Huemer, KH
    Dorner, GT
    Schmetterer, L
    VISION RESEARCH, 2004, 44 (08) : 833 - 838
  • [46] Variations normal retinal capillary blood flow over one month as measured by Heidelberg Retinal Flowmetry
    Martin, B
    Kagemann, L
    Buck, S
    Garrett, M
    Harris, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4893 - 4893
  • [47] Flicker-induced optic nerve blood flow change
    Riva, CE
    Mendel, M
    Petrig, BL
    OCULAR BLOOD FLOW: NEW INSIGHTS INTO THE PATHOGENESIS OF OCULAR DISEASES, 1996, : 128 - 137
  • [48] Investigator's experience with measurements of capillary blood flow by the Heidelberg retina flowmeter (HRF) and reproducibility of the results.
    MullerVelten, R
    Ness, T
    Funk, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 1271 - 1271
  • [49] Role of Neuronal Nitric Oxide Synthase in Regulating Retinal Blood Flow During Flicker-Induced Hyperemia in Cats
    Yoshioka, Takafumi
    Nagaoka, Taiji
    Song, Youngseok
    Yokota, Harumasa
    Tani, Tomofumi
    Yoshida, Akitoshi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (05) : 3113 - 3120
  • [50] Modulation of Heidelberg Retinal Flowmeter parameter flow at the papilla of healthy subjects:: Effect of carbogen, oxygen, high intraocular pressure, and β-blockers
    Haefliger, IO
    Lietz, A
    Griesser, SM
    Ulrich, A
    Schötzau, A
    Hendrickson, P
    Flammer, J
    SURVEY OF OPHTHALMOLOGY, 1999, 43 : S59 - S65