Modification of the Heidelberg Retinal Flowmeter to record pattern and flicker induced blood flow changes

被引:6
|
作者
Schmeisser, ET
Harrison, JM
Sutter, EE
Kiel, J
Elliott, WR
Sponsel, WE
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Ophthalmol, San Antonio, TX 78284 USA
[2] Smith Kettlewell Inst Visual Sci, San Antonio, TX USA
[3] Veridian Inc, San Antonio, TX USA
关键词
retina; flowmetry; circulation; visual stimulation;
D O I
10.1023/A:1022973315359
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We tested a prototype stimulator interfaced with a commercially available scanning laser ophthalmoscope designed to measure retinal capillary perfusion (Heidelberg Retina Flowmeter (HRF)). The add-on stimulator optically superimposed the image of a monitor display on to the subject's retina coaxially with the imaging optics of the HRF. The purpose of the study was to determine if flicker and pattern stimulation presented in this manner could evoke changes in retinal perfusion that could be measured by the HRF. Methods: The prototype stimulator projected 55degrees visual angle circular fields of homogeneous flicker, alternating checkerboard, and multi-focal m-sequence hexagonal patterns on the retina of 10 human subjects during acquisition of images by the HRF. Results: Images were successfully acquired and processed. HRF perfusion values during flicker and pattern stimulation were not significantly different from control values. Conclusions: Results of the present study and a previously published study showing a flicker-induced increase in the HRF perfusion values are contradictory. Retinal perfusion measured by the HRF were not affected by flicker and pattern stimulation delivered through the prototype device. These data are not consistent with a large flicker or pattern induced increase in retinal perfusion. The instrumental modification appears promising. However, the raster scan stimulation technique or some other aspect of stimulation or image acquisition may account for the different results in the present study and previous studies in our laboratory and in the laboratories of other investigators.
引用
收藏
页码:257 / 263
页数:7
相关论文
共 50 条
  • [1] Modification of the Heidelberg retinal flowmeter to record pattern and flicker induced blood flow changes
    Elmar T. Schmeisser
    Joseph M. Harrison
    Erich E. Sutter
    Jeffrey Kiel
    W. Rowe Elliott
    W. E. Sponsel
    Documenta Ophthalmologica, 2003, 106 : 257 - 263
  • [2] Retinal blood flow changes in diabetic retinopathy measured with the Heidelberg scanning laser Doppler flowmeter
    M. H. M. Cuypers
    Jocelyn S. Kasanardjo
    Bettine C. P. Polak
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238 : 935 - 941
  • [3] Retinal blood flow changes in diabetic retinopathy measured with the Heidelberg scanning laser Doppler flowmeter
    Cuypers, MHM
    Kasanardjo, JS
    Polak, BCP
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (12) : 935 - 941
  • [4] Variability of blood flow measurements using the Heidelberg retinal flowmeter.
    Lundmark, P
    Rawji, M
    Flanagan, J
    Trope, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1215 - 1215
  • [5] The effect of retinal bleaching on retinal capillary blood flow as measured by Heidelberg Retina Flowmeter
    Lanzi, IM
    Nicholl, JE
    Azuara, A
    Spaeth, GL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3609 - 3609
  • [6] The repeatability of various methods of analyses for retinal blood flow obtained with the Heidelberg Retinal Flowmeter
    Donohue, E
    Oguri, A
    McKendrick, A
    Wang, L
    Cull, G
    Cioffi, GA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S557 - S557
  • [7] Effect of 10 HZ flicker on retinal hemodynamics measured by the Heidelberg retinal flowmeter (HRF)
    Harrison, JM
    Elliott, WR
    Kiel, JW
    Sponsel, WE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1214 - 1214
  • [8] The acute effect of smoking on retinal blood flow: An assessment with the Heidelberg retina flowmeter
    Chen, H
    Hudson, C
    Ataullah, S
    McLeod, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1237 - 1237
  • [9] Pointwise analysis reveals that Heidelberg retinal flowmeter measurements of human retinal blood flow are influenced by illumination level
    Kagemann, L
    Harris, A
    Chung, HS
    Martin, BJ
    Kiesling, K
    Elvambuena, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S508 - S508
  • [10] Flicker-induced changes in retinal blood flow assessed by Doppler optical coherence tomography
    Wang, Yimin
    Fawzi, Amani A.
    Tan, Ou
    Zhang, Xinbo
    Huang, David
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (07): : 1852 - 1860