Electrically conductive adhesives at microwave frequencies

被引:12
|
作者
Dernevik, M [1 ]
Sihlbom, R [1 ]
Axelsson, K [1 ]
Lai, ZH [1 ]
Liu, JH [1 ]
Starski, P [1 ]
机构
[1] Chalmers Univ Technol, Dept Microwave Engn, S-41296 Gothenburg, Sweden
关键词
D O I
10.1109/ECTC.1998.678839
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we present results from measurements on epoxy-based anisotropic and isotropic, electrically conductive adhesives, ACAs and ICAs respectively. We study two different types of connections, a flip-chip bonded silicon test chips and a simple transmission line gap bridged by a copper foil. These measurements are referenced to equivalent solder joints. The silicon chip is a standard test chip. The test chips are mounted on three different substrates, a rigid FR-4 board, flexible board and a high-frequency Teflon-based duroid substrate. We also discuss two electrical models for the connections, an equivalent RC model and a stochastic model, based on random particle distribution. The equivalent electrical model is based on physical considerations and the parameters are then fitted to measurement data in the high frequency CAD tool HP MDS. All the adhesive and solder interconnections are measured before and after temperature cycling and humidity tests. The temperature dependence of the connections S-parameters are also studied in a temperature controlled environment. A HP8510 network analyzer is used to measure scattering parameters. On rigid and flexible boards, the frequency range investigated is 500 MHz to 8 GHz, and on duroid mounted flip-chips and bridges, the range is 1 GHz to 30 GHz. The Thru-Reflect-Line calibration procedure is used to get the best possible calibration. Power testing is used with the Cu bridge assembly to find the maximum power transmission through an electrically conductive adhesive interconnect. This is done at relevant microwave frequencies Results indicate that the isotropic adhesive interconnections handle high power throughput well. The adhesive joints are subjected to a maximum peak pulsed power of 250 W. Maximum work factor of the pulsed signal is 10%. The effects of different particle sizes and materials in the ACAs are systematically investigated. Three different particle sizes and two particle materials are examined. All adhesives considered show similar electrical properties and are all suitable for adhesive electrical interconnections. The microstructure of the adhesive joints is studied by cross-sectioning using Scanning Electron Microscopy (SEM) before and after temperature cycling.
引用
收藏
页码:1026 / 1030
页数:5
相关论文
共 50 条
  • [41] The interaction mechanism of dicarboxylic acids and electrically conductive adhesives
    Chen, Xiang-Yan
    Zhang, Zhong-Xian
    Xiao, Fei
    Gongneng Cailiao/Journal of Functional Materials, 2011, 42 (05): : 947 - 950
  • [42] Fundamental understanding of conductivity establishment for electrically conductive adhesives
    Fan, LH
    Tison, C
    Wong, CP
    52ND ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, 2002 PROCEEDINGS, 2002, : 1154 - 1157
  • [43] A study of electrically conductive adhesives as a manufacturing solder alternative
    Coughlan, F. M.
    Lewis, H. J.
    JOURNAL OF ELECTRONIC MATERIALS, 2006, 35 (05) : 912 - 921
  • [44] High frequency interconnections using electrically conductive adhesives
    Dernevik, M
    Liu, J
    Starski, P
    MIKON-98: 12TH INTERNATIONAL CONFERENCE ON MICROWAVES & RADAR, VOLS 1-4, 1998, : 680 - 683
  • [45] Testing of Techniques for Improvement of Conductivity of Electrically Conductive Adhesives
    Mach, Pavel
    Richter, Lukas
    Pietrikova, Alena
    ESTC 2008: 2ND ELECTRONICS SYSTEM-INTEGRATION TECHNOLOGY CONFERENCE, VOLS 1 AND 2, PROCEEDINGS, 2008, : 305 - +
  • [46] A study of electrically conductive adhesives as a manufacturing solder alternative
    F. M. Coughlan
    H. J. Lewis
    Journal of Electronic Materials, 2006, 35 : 912 - 921
  • [47] Electrically conductive adhesives for electronic packaging and assembly applications
    Matienzo, L. J.
    Das, R. N.
    Egitto, F. D.
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2008, 22 (8-9) : 853 - 869
  • [48] ELECTRICAL, STRUCTURAL AND PROCESSING PROPERTIES OF ELECTRICALLY CONDUCTIVE ADHESIVES
    LI, L
    LIZZUL, C
    KIM, H
    SACOLICK, I
    MORRIS, JE
    IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1993, 16 (08): : 843 - 851
  • [49] ELECTRICALLY CONDUCTIVE ADHESIVES - A PROSPECTIVE ALTERNATIVE FOR SMD SOLDERING
    JAGT, JC
    BERIS, PJM
    LIJTEN, GFCM
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART B-ADVANCED PACKAGING, 1995, 18 (02): : 292 - 298
  • [50] Electrical characterizations and considerations of electrically conductive adhesives (ECAs)
    Shimada, Y
    Lu, DQ
    Wong, CP
    INTERNATIONAL SYMPOSIUM ON ADVANCED PACKAGING MATERIALS: PROCESSES, PROPERTIES AND INTERFACES, PROCEEDINGS, 2000, : 336 - 342