ICP-AES determination of trace rare earth elements in environmental and food samples by on-line separation and preconcentration with acetylacetone-modified silica gel using microcolumn

被引:47
作者
Zhang, Nan [1 ]
Huang, Chaozhang [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
D O I
10.2116/analsci.23.997
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method of online microcolumn separation and preconcentration coupled to inductively coupled plasma atomic emission spectrometry (ICP-AES) with the use of acetylacetone-modified silica gel as packing material was developed for the determination of trace rare earth elements (REEs) in environmental and food samples. The main parameters affecting online separation/preconcentration, including pH, sample flow rate, sample volume, elution and interfering ions, have been investigated in detail. Under the optimized operating conditions, the adsorption capacity values for Sc, Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu were 25.65, 23.23, 24.01, 19.40, 22.89, 23.77, 24.40, 23.96, 25.58, 25.15, 24.86, 22.75, 16.05, 24.13, 26.51 and 27.93 mg g(-1), respectively. Detection limits (3 sigma) based on three times standard deviations of the blanks by 8 replicates were in the range from 48 pg mL(-1) for Lu to 1003 pg mL(-1) for Sm. With 90 s preconcentration time and 10 s elution time, the enrichment factor was 10 and the sample frequency was 28 h(-1). The precisions (RSDs) obtained by determination of a 250 ng mL(-1) (n = 8) REEs standard solution were in the range from 1.7% for Y to 4.4% for Sm. The proposed method was successfully applied to the determination of trace REEs in pig liver, agaric and mushroom. To validate the proposed method, we analyzed three certified reference materials (GBW07401 soil, GBW07301a sediment, and GBW07605 tea leaves). The determined values were in a good agreement with the certified values. The method is rapid, selective, sensitive and applicable to the determination of trace REEs in biological and environmental samples with complicated matrix effects.
引用
收藏
页码:997 / 1002
页数:6
相关论文
共 29 条
[1]   Spectral interferences in the determination of traces of scandium, yttrium and rare earth elements in 'pure' rare earth matrices by inductively coupled plasma atomic emission spectrometry: Part VI - Ytterbium [J].
Aleksieva, L ;
Daskalova, N ;
Velichkov, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (08) :1339-1350
[2]   On-line preconcentration of some rare earth elements in water samples using C18-cartridge modified with 1-(2-pyridylazo) 2-naphtol (PAN) prior to simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP-OES) [J].
Bahramifar, N ;
Yamini, Y .
ANALYTICA CHIMICA ACTA, 2005, 540 (02) :325-332
[3]   Vaporization and removal of silica for the direct analysis of geological materials by slurry sampling electrothermal vaporization-inductively coupled plasma-mass spectrometry [J].
Ben Younes, ME ;
Grégoire, DC ;
Chakrabarti, CL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) :1703-1708
[4]   ENVIRONMENTAL ANALYSIS PROBLEMS CREATED BY UNEXPECTED VOLATILE BERYLLIUM COMPOUNDS IN VARIOUS SAMPLES [J].
BLACK, MS ;
SIEVERS, RE .
ANALYTICAL CHEMISTRY, 1973, 45 (09) :1773-1775
[5]   Distribution of some rare earth elements and their binding species with proteins in human liver studied by instrumental neutron activation analysis combined with biochemical techniques [J].
Chen, CY ;
Zhang, PQ ;
Chai, ZF .
ANALYTICA CHIMICA ACTA, 2001, 439 (01) :19-27
[6]   3-CHLOROPROPYLTRIALKOXYSILANES - KEY INTERMEDIATES FOR THE COMMERCIAL PRODUCTION OF ORGANOFUNCTIONALIZED SILANES AND POLYSILOXANES [J].
DESCHLER, U ;
KLEINSCHMIT, P ;
PANSTER, P .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 1986, 25 (03) :236-252
[7]   ULTRATRACE ANALYSIS FOR BERYLLIUM IN TERRESTRIAL, METEORITIC, AND APOLLO-11 AND APOLLO-12 LUNAR SAMPLES USING ELECTRON CAPTURE GAS CHROMMATOGRAPHY [J].
EISENTRAUT, KJ ;
GRIEST, DJ ;
SIEVERS, RE .
ANALYTICAL CHEMISTRY, 1971, 43 (14) :2003-+
[8]  
Genova N, 2001, J RADIOANAL NUCL CH, V249, P355
[9]   Separation and microcolumn preconcentration of traces of rare earth elements on nanoscale TiO2 and their determination in geological samples by ICP-AES [J].
Hang, YP ;
Qin, YC ;
Shen, J .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10) :957-960
[10]   Speciation of yttrium and lanthanides in natural water by inductively coupled plasma mass spectrometry after preconcentration by ultrafiltration and with a chelating resin [J].
Haraguchi, H ;
Itoh, A ;
Kimata, C ;
Miwa, H .
ANALYST, 1998, 123 (05) :773-778