Effects of continuous-flow left ventricular assist devices on cerebral hemodynamics

被引:6
|
作者
Karahan, Mehmet [1 ]
Kocabeyoglu, Sinan Sabit [1 ]
Kervan, Umit [1 ]
Sert, Dogan Emre [1 ]
Aygun, Emre [1 ]
Tola, Muharrem [2 ]
Demirkan, Burcu [3 ]
Mungan, Semra [4 ]
Kursun, Oguzhan [4 ]
Catav, Zeki [1 ]
Pac, Mustafa [1 ]
机构
[1] Turkiye Yuksek Ihtisas Hosp, Cardiovasc Surg, Kizilay St 4 Altindag, TR-06100 Ankara, Turkey
[2] Turkiye Yuksek Ihtisas Hosp, Radiol, Ankara, Turkey
[3] Turkiye Yuksek Ihtisas Hosp, Cardiol, Ankara, Turkey
[4] Ankara Numune Hosp, Neurol, Ankara, Turkey
关键词
carotid artery; middle cerebral artery; pulsatility index; resistive index; ventricular assist device; ADVANCED HEART-FAILURE; BLOOD-FLOW; CAROTID CIRCULATION; RESISTIVE INDEX; ISCHEMIC-STROKE; VELOCITY; AUTOREGULATION; RESISTANCE; ARTERIES;
D O I
10.1111/aor.13616
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Continuous-flow left ventricular assist devices (LVADs) reduce peak systolic flow, increase diastolic flow, and eliminate pulsatility of circulation. Altered blood flow may lead to a change in end-organ perfusion. Analysis of the flow dynamics of the arteries of end organs, such as the brain, may indicate whether an organ is perfused sufficiently. The aim of this study is to evaluate and identify the flow pattern changes of carotid (CA) and middle cerebral arteries (MCA) in LVAD patients and to compare with heart failure patients and healthy volunteers. Eighty-nine individuals were included in this cross-sectional study. Participants were divided into three groups: LVAD patients (n = 31), heart failure patients (n = 26), and healthy volunteers (n = 27). Carotid and transcranial Doppler ultrasonography were performed for all study groups for peak systolic velocity (PSV), end-diastolic velocity (EDV), pulsatility (PI), and resistive (RI) indices of CA and MCA. Flow dynamics were compared between the groups. Doppler ultrasonographic data were analyzed at a median 12 (3-47) months after LVAD implantation. CA-PSV was lower in LVAD group compared with the other two groups (P < .001), MCA-PSV of LVAD and heart failure groups were similar and lower than healthy volunteers (P < .05). The highest values for CA-EDV were found in the LVAD group (P < .05). MCA-EDV values were found to be lowest in heart failure group (P < .05). For PI and RI, in all CA and MCA, the LVAD group had lower indices compared with the other two groups (P < .001). In addition, MCA flow analysis in patients with LVADs was identified for the first time with this study.
引用
收藏
页码:457 / 464
页数:8
相关论文
共 50 条
  • [21] Effects of Continuous-Flow Left Ventricular Assist Device Therapy on Peripheral Vascular Function
    Kaya, Ersin
    Kocabas, Umut
    Simsek, Evrim
    Nalbantgil, Sanem
    Kahraman, Umit
    Engin, Cagatay
    Yagdi, Tahir
    Ozbaran, Mustafa
    Akilli, Azem
    ASAIO JOURNAL, 2022, 68 (02) : 214 - 219
  • [22] Existing issues and valid concerns in continuous-flow ventricular assist devices
    Hetzer, Roland
    Walter, Eva Maria Delmo
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (12) : 949 - 959
  • [23] Complete coronary thrombolysis on continuous-flow left ventricular assist device
    Ichihara, Yuki
    Hamasaki, Azumi
    Saito, Satoshi
    Niinami, Hiroshi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2021, 60 (03) : 721 - 721
  • [24] Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices
    Cross, Troy J.
    Sajgalik, Pavol
    Fabian, Vratislav
    Matera, Lukas
    Kushwaha, Sudhir S.
    Maltais, Simon
    Stulak, John M.
    Schirger, John A.
    Johnson, Bruce D.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2020, 43 (02) : 99 - 108
  • [25] Discriminatory performance of positive urine hemoglobin for detection of significant hemolysis in patients with continuous-flow left ventricular assist devices
    Gayalas, Michael V.
    Breskin, Alexander
    Yuzefpolskaya, MeLana
    Eisenberger, Andrew
    Castagna, Francesco
    Demmer, Ryan T.
    Flannery, Margaret
    Garan, A. Reshad
    Takeda, Koji
    Takayama, Hiroo
    Naka, Yoshifumi
    Topkara, Veli K.
    Colombo, Paolo C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (01) : 59 - 63
  • [26] Long-term continuous-flow left ventricular assist devices (LVAD) as bridge to heart transplantation
    Pozzi, Matteo
    Giraud, Raphael
    Tozzi, Piergiorgio
    Bendjelid, Karim
    Robin, Jacques
    Meyer, Philippe
    Obadia, Jean Francois
    Banfi, Carlo
    JOURNAL OF THORACIC DISEASE, 2015, 7 (03) : 532 - 542
  • [27] Medical management of patients with continuous-flow left ventricular assist devices topical collection on heart failure
    Devore A.D.
    Mentz R.J.
    Patel C.B.
    Current Treatment Options in Cardiovascular Medicine, 2014, 16 (2)
  • [28] Erythrocyte aging as a mechanism of anemia and a biomarker of device thrombosis in continuous-flow left ventricular assist devices
    Taimeh, Ziad
    Koene, Ryan J.
    Furne, Julie
    Singal, Ashish
    Eckman, Peter M.
    Levitt, Michael D.
    Pritzker, Marc R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (06) : 625 - 632
  • [29] Colo-colonic anastomosis in a continuous-flow left ventricular assist device patient
    Knaus, William J.
    Olson, Craig H.
    ASIAN JOURNAL OF SURGERY, 2017, 40 (03) : 232 - 235
  • [30] Restoration of Pulsatile Flow Reduces Sympathetic Nerve Activity Among Individuals With Continuous-Flow Left Ventricular Assist Devices
    Cornwell, William K.
    Tarumi, Takashi
    Stickford, Abigail
    Lawley, Justin
    Roberts, Monique
    Parker, Rosemary
    Fitzsimmons, Catherine
    Kibe, Julius
    Ayers, Colby
    Markham, David
    Drazner, Mark H.
    Fu, Qi
    Levine, Benjamin D.
    CIRCULATION, 2015, 132 (24) : 2316 - 2322