Exergy analysis of a hybrid ground-source heat pump system

被引:50
|
作者
Menberg, Kathrin [1 ,2 ]
Heo, Yeonsook [2 ]
Choi, Wonjun [3 ]
Ooka, Ryozo [3 ]
Choudhary, Ruchi [1 ]
Shukuya, Masanori [4 ]
机构
[1] Univ Cambridge, Dept Engn, Trumpington St, Cambridge, England
[2] Univ Cambridge, Dept Architecture, 1-5 Scroope Terrace, Cambridge, England
[3] Univ Tokyo, Inst Ind Sci, Meguro Ku, 4-6-1 Komaba, Tokyo, Japan
[4] Tokyo City Univ, Dept Restorat Ecol & Built Environm, Tokyo, Japan
基金
英国工程与自然科学研究理事会;
关键词
Energy analysis; Ground source heat pump systems; Hybrid systems; AIR-CONDITIONING SYSTEM; THERMODYNAMIC ANALYSIS; THEORETICAL-ANALYSIS; POWER-PLANT; ENERGY; PERFORMANCE; SUSTAINABILITY; BUILDINGS; OPERATION; INDUSTRY;
D O I
10.1016/j.apenergy.2017.06.076
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In contrast to energy analysis, the analysis of energy allows the evaluation of the quality of different energy flows and enables a comprehensive assessment of inefficiencies within a system and its individual components by accounting for exergy consumption. While exergy analysis methods have been applied to a variety of conventional and renewable energy supply systems, there is still a lack of knowledge regarding the exergy flows and exergy efficiency of hybrid ground-source heat pump systems with a supplementary boiler. In this study, we develop a thermodynamic model for each subsystem in a hybrid heating and cooling system of an existing building by applying the concept of cool and warm exergy. A comparison of the exergy consumption of the hybrid system in heating and cooling reveals that there are significant differences regarding the components that attribute most to the overall exergy consumption in the system. Due to these differences the true exergy performance of the system in heating mode (similar to 30%) is twice as high as for cooling mode (similar to 15%), while the natural exergy performance is considerably better in cooling mode (similar to 26% to similar to 3%). Potential measures to enhance the exergy performance based on changes in the operational settings of the system and the improvement of the building envelope were found to have a more significant effect on heating performance than on cooling performance. In general, measures that affect the amount of thermal energy delivered by the system appear to be more effective than changes to the operational settings of energy supply systems. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:31 / 46
页数:16
相关论文
共 50 条
  • [1] Experiments and exergy analysis for a carbon dioxide ground-source heat pump in cooling mode
    Skye, Harrison M.
    Wu, Wei
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 920 - 937
  • [2] Hybrid ground-source heat pump system with active air source regeneration
    Allaerts, K.
    Coomans, M.
    Salenbien, R.
    ENERGY CONVERSION AND MANAGEMENT, 2015, 90 : 230 - 237
  • [3] Comprehensive exergy analysis of a ground-source heat pump system for both building heating and cooling modes
    Bi, Yuehong
    Wang, Xinhong
    Liu, Yun
    Zhang, Hua
    Chen, Lingen
    APPLIED ENERGY, 2009, 86 (12) : 2560 - 2565
  • [4] Thermoeconomic analysis of ground-source heat pump systems
    Kwak, Ho-Young
    You, Yungpil
    Oh, Si-Doek
    Jang, Ha-Na
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2014, 38 (02) : 259 - 269
  • [5] EXERGY ANALYSIS OF A RADIANT CEILING ASSISTED GROUND-SOURCE HEAT PUMP AIR-CONDITIONING SYSTEM
    Sui, Xuemin
    Zhang, Xu
    Lin, Ting
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1844 - 1851
  • [6] Dynamic thermal analysis of a residential ground-source heat pump
    Yang, S.
    Lee, S. B.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 37
  • [7] Thermodynamic analysis of a ground-source heat pump system for district heating
    Hepbasli, A
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2005, 29 (07) : 671 - 687
  • [8] Energy and exergy analysis of a ground source (geothermal) heat pump system
    Hepbasli, A
    Akdemir, O
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (05) : 737 - 753
  • [9] Energy and exergy analysis of a combined ground source heat pump system
    Ozturk, Murat
    APPLIED THERMAL ENGINEERING, 2014, 73 (01) : 362 - 370
  • [10] Optimized Design of Ground-Source Heat Pump System Heat Exchanger
    Shi, Zhigang
    Song, Shangping
    Hu, Songtao
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 723 - 730