Obstetric outcome in women who present with a reduction in fetal movements in the third trimester of pregnancy

被引:37
作者
Harrington, K
Thompson, O
Jordan, L
Page, J
Carpenter, RG
Campbell, S
机构
[1] Homerton Hosp, Acad Dept Obstet & Gynaecol, London E9 6SR, England
[2] St Bartholomews Hosp, London, England
[3] Univ London Kings Coll Hosp, London, England
[4] Univ London London Sch Hyg & Trop Med, Dept Med Stat, London WC1E 7HT, England
[5] St George Hosp, London, England
[6] Sch Med, London, England
关键词
abdominal circumference; amniotic fluid volume; decreased fetal movement; Doppler ultrasound; fetal heart rate; obstetric outcome; perinatal outcome; umbilical artery pulsatility index;
D O I
10.1515/jpme.1998.26.2.77
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
A complaint of decreased fetal movements is a common indication for the assessment of fetal well being. The aim of this study was to review the outcome of a group of women whose primary indication for referral was decreased fetal movements. Over a 20 month period, 435 patients were seen in the fetal assessment unit of an inner London teaching hospital, following a primary complaint of reduced fetal movements. Investigations included: the fetal abdominal circumference (AC), amniotic fluid volume (AFV), the umbilical artery pulsatility index (UAPI) derived from Doppler ultrasound waveforms and a computerised analysis of fetal heart rate (FHR) recordings or cardiotocograph (CTG). Outcome measures were: gestational age at delivery, Apgar score < 7 at 5 minutes, admission to the Special Care Baby Unit (SCBU), the need for delivery by an emergency cesarean section for fetal compromise (CSFC), and any perinatal deaths. A comparison of actual versus expected outcome for women with decreased fetal movement revealed the following relative risks, with the 95 % confidence intervals (CI) in brackets; low 5 minute Apgar score 0.03 vs. 0.05 expected (CI = 0.01,0.05), SCBU admission, 0.06 vs. 0.07 (0.04, 0.08), and preterm delivery, 0.08 vs. 0.11 (0.05, 0.10). Cesarean sections for fetal compromise, 0.07 vs. 0.053 (0.050-0.096). The addition of FHR monitoring to standard ultrasound assessment of well being did not appear to confer any added benefit. There were no fetal deaths. The outcome for pregnancies where the mother presents with decreased fetal movements in the third trimester is comparable with the outcome for the general population.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 23 条
  • [1] COMPARISON OF UMBILICAL-ARTERY VELOCIMETRY AND CARDIOTOCOGRAPHY FOR SURVEILLANCE OF SMALL-FOR-GESTATIONAL-AGE FETUSES
    ALMSTROM, H
    AXELSSON, O
    CNATTINGIUS, S
    EKMAN, G
    MAESEL, A
    ULMSTEN, U
    ARSTROM, K
    MARSAL, K
    [J]. LANCET, 1992, 340 (8825) : 936 - 940
  • [2] CHANG TC, 1992, OBSTET GYNECOL, V80, P1030
  • [3] COX DN, 1987, OBSTET GYNECOL, V70, P673
  • [4] DAWES G, 1994, J PERINAT MED, V22, P491
  • [5] GAZIANO EP, 1994, AM J OBSTET GYNECOL, V170, P1734
  • [6] COMPARISON BETWEEN SUBJECTIVE AND ULTRASOUND ASSESSMENTS OF FETAL MOVEMENT
    GETTINGER, A
    ROBERTS, AB
    CAMPBELL, S
    [J]. BRITISH MEDICAL JOURNAL, 1978, 2 (6130) : 88 - 90
  • [7] Gibb D, 1992, FETAL MONITORING PRA
  • [8] FETAL UMBILICAL ARTERY FLOW VELOCITY WAVEFORMS AND PLACENTAL RESISTANCE - PATHOLOGICAL CORRELATION
    GILES, WB
    TRUDINGER, BJ
    BAIRD, PJ
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1985, 92 (01): : 31 - 38
  • [9] GRANT A, 1989, LANCET, V2, P345
  • [10] Groome LJ, 1995, J DEV BEHAV PEDIATR, V16, P391