Calibration of PET/CT scanners for multicenter studies on differentiated thyroid cancer with 124I

被引:6
作者
Kist, Jakob W. [1 ]
van der Vlies, Manfred [2 ]
Hoekstra, Otto S. [3 ]
Greuter, Henri N. J. M. [3 ]
de Keizer, Bart [4 ]
Stokkel, Marcel P. M. [1 ]
Vogel, Wouter V. [1 ]
Huisman, Marc C. [3 ]
van Lingen, Arthur [3 ]
机构
[1] Netherlands Canc Inst, Dept Nucl Med, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
[2] Groene Hart Ziekenhuis, Dept Diagnost, Bleulandweg 10, NL-2803 HH Gouda, Netherlands
[3] Vrije Univ Amsterdam, Med Ctr, Dept Radiol & Nucl Med, De Boelelaan 1117, NL-1081 HV Amsterdam, Netherlands
[4] Univ Med Ctr Utrecht, Dept Nucl Med, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
来源
EJNMMI RESEARCH | 2016年 / 6卷
关键词
Calibration; Multicenter; Quantification; PET/CT; Iodine-124; Differentiated thyroid cancer; DOSIMETRY; PROTOCOL;
D O I
10.1186/s13550-016-0191-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Studies on imaging of differentiated thyroid cancer (DTC) using I-124 often require a multicenter approach, as the prevalence of DTC is low. Calibration of participating scanners is required to obtain comparable quantification. As determination of a well-defined range of recovery coefficients is complicated for various reasons, a simpler approach based on the assumption that the iodine uptake is highly focal with a background that significantly lacks radioactivity might be more efficient. For each scanner, a linear conversion between known and observed activity can be derived, allowing quantification that can be traced to a common source for all scanners within one study-protocol. The aim of this paper is to outline a procedure using this approach in order to set up a multicenter calibration of PET/CT scanners for I-124. Methods: A cylindrical polyethylene phantom contained six 2-ml vials with reference activities of similar to 2, 10, 20, 100, 400, and 2000 kBq, produced by dilution from a known activity. The phantom was scanned twice on PET/CT scanners of participating centers within 1 week. For each scanner, the best proportional and linear fit between measured and known activities were derived and based on statistical analyses of the results of all scanners; it was determined which fit should be applied. In addition, a Bland-Altman analysis was done on calibrated activities with respect to reference activities to asses the relative precision of the scanners. Results: Nine Philips (vendor A) and nine Siemens (vendor B) PET/CT scanners were calibrated in a time period of 3 days before and after the reference time. No significant differences were detected between the two subsequent scans on any scanner. Six fitted intercepts of vendor A were significantly different from zero, so the linear model was used. Intercepts ranged from -8 to 26 kBq and slopes ranged from 0.80 to 0.98. Bland-Altman analysis of calibrated and reference activities showed that the relative error of calibrated activities was smaller than that of uncalibrated activities. Conclusions: A simplified multicenter calibration procedure for PET/CT scans that show highly focal uptake and negligible background is feasible and results in more precise quantification. Our procedure can be used in multicenter I-124 PET scans focusing on (recurrent) DTC.
引用
收藏
页数:8
相关论文
共 19 条
  • [1] [Anonymous], RESEARCH 4 LIF
  • [2] A Recommendation for Revised Dose Calibrator Measurement Procedures for 89Zr and 124I
    Beattie, Bradley J.
    Pentlow, Keith S.
    O'Donoghue, Joseph
    Humm, John L.
    [J]. PLOS ONE, 2014, 9 (09):
  • [3] FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
    Boellaard, Ronald
    Delgado-Bolton, Roberto
    Oyen, Wim J. G.
    Giammarile, Francesco
    Tatsch, Klaus
    Eschner, Wolfgang
    Verzijlbergen, Fred J.
    Barrington, Sally F.
    Pike, Lucy C.
    Weber, Wolfgang A.
    Stroobants, Sigrid
    Delbeke, Dominique
    Donohoe, Kevin J.
    Holbrook, Scott
    Graham, Michael M.
    Testanera, Giorgio
    Hoekstra, Otto S.
    Zijlstra, Josee
    Visser, Eric
    Hoekstra, Corneline J.
    Pruim, Jan
    Willemsen, Antoon
    Arends, Bertjan
    Kotzerke, Joerg
    Bockisch, Andreas
    Beyer, Thomas
    Chiti, Arturo
    Krause, Bernd J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (02) : 328 - 354
  • [4] 124I-PET dosimetry in advanced differentiated thyroid cancer:: Therapeutic impact
    Freudenberg, L. S.
    Jentzen, W.
    Goerges, R.
    Petrich, T.
    Marlowe, R. J.
    Knust, J.
    Bockisch, A.
    [J]. NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2007, 46 (04): : 121 - 128
  • [5] Selumetinib-Enhanced Radioiodine Uptake in Advanced Thyroid Cancer
    Ho, Alan L.
    Grewal, Ravinder K.
    Leboeuf, Rebecca
    Sherman, Eric J.
    Pfister, David G.
    Deandreis, Desiree
    Pentlow, Keith S.
    Zanzonico, Pat B.
    Haque, Sofia
    Gavane, Somali
    Ghossein, Ronald A.
    Ricarte-Filho, Julio C.
    Dominguez, Jose M.
    Shen, Ronglai
    Tuttle, R. Michael
    Larson, Steve M.
    Fagin, James A.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (07) : 623 - 632
  • [6] ICRP, 1988, ANN ICRP, V18
  • [7] Optimized 124I PET dosimetry protocol for radioiodine therapy of differentiated thyroid cancer
    Jentzen, Walter
    Freudenberg, Lutz
    Eising, Emst G.
    Sormenschein, Wilfried
    Knust, Jochen
    Bockisch, Andreas
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (06) : 1017 - 1023
  • [8] Assessment of Lesion Response in the Initial Radioiodine Treatment of Differentiated Thyroid Cancer Using 124I PET Imaging
    Jentzen, Walter
    Hoppenbrouwers, Jan
    van Leeuwen, Paul
    van der Velden, Daan
    van de Kolk, Rudie
    Poeppel, Thorsten Dirk
    Nagarajah, James
    Brandau, Wolfgang
    Bockisch, Andreas
    Rosenbaum-Krumme, Sandra
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (11) : 1759 - 1765
  • [9] Experimental investigation of factors affecting the absolute recovery coefficients in iodine-124 PET lesion imaging
    Jentzen, Walter
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (08) : 2365 - 2398
  • [10] Recurrent differentiated thyroid cancer: towards personalized treatment based on evaluation of tumor characteristics with PET (THYROPET Study): study protocol of a multicenter observational cohort study
    Kist, Jakob W.
    de Keizer, Bart
    Stokkel, Marcel P. M.
    Hoekstra, Otto S.
    Vogel, Wouter V.
    [J]. BMC CANCER, 2014, 14