Measurement of ribavirin and evaluation of its stability in human plasma by high-performance liquid chromatography with UV detection

被引:39
作者
Loregian, Arianna
Scarpa, Maria Cristina
Pagni, Silvana
Parisi, Saverio Giuseppe
Palu, Giorgio
机构
[1] Univ Padua, Dept Histol Microbiol & Med Biotechnol, I-35121 Padua, Italy
[2] Padua Univ Hosp, Clin Microbiol & Virol Unit, I-35121 Padua, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 856卷 / 1-2期
关键词
ribavirin; human plasma; solid-phase extraction; high-performance liquid chromatography; UV method; ribavirin stability; therapeutic drug monitoring;
D O I
10.1016/j.jchromb.2007.05.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple high-performance liquid chromatography method for the determination of the antiviral agent ribavirin in human plasma was developed and validated. The method involved solid-phase extraction on phenyl boronic acid cartridges, a reversed-phase liquid chromatography with a Waters Atlantis dC 18 (150 mm x 3.9 mm, 5 mu m) column and a mobile phase consisting of 10 mM potassium phosphate buffer (pH 4.0), and ultraviolet detection at 207 nm. This assay proved to be sensitive (lower limit of quantification of 0.05 mu g/ml), linear (correlation coefficients >= 0.997), specific (no interference with various potentially co-administrated drugs), reproducible (both intra-day and inter-day coefficients of variation <= 4.3%), and accurate (deviations ranged from -5.6 to 2.2% and from -6.0 to 4.0% for intra-day and inter-day analysis, respectively). The method was applied to therapeutic monitoring of patients undergoing ribavirin treatment for hepatitis C and proved to be robust and reliable. Thus, this method provides a simple, sensitive, precise and reproducible assay for dosing ribavirin that can be readily adaptable to routine use by clinical laboratories with standard equipment. In addition, we evaluated the stability of ribavirin in plasma under various conditions, since no detailed study on thermal stability of ribavirin has been reported so far and discrepant data do exist on ribavirin stability upon conditions that clinical samples commonly experience. Ribavirin was stable in human plasma stored at room temperature for at least 24 h or at -20 degrees C for up to I month, after three freeze-thaw cycles, as well as in samples undergoing heat inactivation of infectious viruses for 60 min at 60 degrees C. The drug was also stable in processed samples stored at -20 degrees C for 3 days (as dried extracts) or at 20 degrees C for 4 days (as reconstituted samples). (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:358 / 364
页数:7
相关论文
共 29 条
  • [1] SENSITIVE RADIOIMMUNOASSAY FOR THE BROAD-SPECTRUM ANTIVIRAL AGENT RIBAVIRIN
    AUSTIN, RK
    TREFTS, PE
    HINTZ, M
    CONNOR, JD
    KAGNOFF, MF
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1983, 24 (05) : 696 - 701
  • [2] Determination of ribavirin in human serum and plasma by capillary electrophoresis
    Breadmore, MC
    Theurillat, R
    Thormann, W
    [J]. ELECTROPHORESIS, 2004, 25 (10-11) : 1615 - 1622
  • [3] Validation of liquid/liquid extraction method coupled with HPLC-UV for measurement of ribavirin plasma levels in HCV-positive patients
    D'Avolio, A
    Ibañez, A
    Sciandra, M
    Siccardi, M
    de Requena, DG
    Bonora, S
    Di Perri, G
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 835 (1-2): : 127 - 130
  • [4] Peginterferon alfa-2a plus ribavirin for chronic hepatitis C virus infection.
    Fried, MW
    Shiffman, ML
    Reddy, KR
    Smith, C
    Marinos, G
    Goncales, FL
    Haussinger, D
    Diago, M
    Carosi, G
    Dhumeaux, D
    Craxi, A
    Lin, A
    Hoffman, J
    Yu, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (13) : 975 - 982
  • [5] BIOCHEMISTRY AND CLINICAL-APPLICATIONS OF RIBAVIRIN
    GILBERT, BE
    KNIGHT, V
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1986, 30 (02) : 201 - 205
  • [6] Glue P, 1999, SEMIN LIVER DIS, V19, P17
  • [7] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC) ASSAY FOR RIBAVIRIN AND COMPARISON OF THE HPLC ASSAY WITH RADIOIMMUNOASSAY
    GRANICH, GG
    KROGSTAD, DJ
    CONNOR, JD
    DESROCHERS, KL
    SHERWOOD, C
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1989, 33 (03) : 311 - 315
  • [8] Liquid chromatography assay for routine monitoring of cellular ribavirin levels in blood
    Inoue, Y
    Homma, M
    Matsuzaki, Y
    Shibata, M
    Matsumura, T
    Ito, T
    Mitamura, K
    Tanaka, N
    Kohda, Y
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2004, 48 (10) : 3813 - 3816
  • [9] Population pharmacokinetic and pharmacodynamic analysis of ribavirin in patients with chronic hepatitis C
    Jen, JF
    Glue, P
    Gupta, S
    Zambas, D
    Hajian, G
    [J]. THERAPEUTIC DRUG MONITORING, 2000, 22 (05) : 555 - 565
  • [10] Ribavirin and interferon alfa-2b in chronic hepatitis C: assessment of possible pharmacokinetic and pharmacodynamic interactions
    Khakoo, S
    Glue, P
    Grellier, L
    Wells, B
    Bell, A
    Dash, C
    Murray-Lyon, I
    Lypnyj, D
    Flannery, B
    Walters, K
    Dusheiko, GM
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1998, 46 (06) : 563 - 570