Measurement of exposure buildup factors: The influence of scattered photons on gamma-ray attenuation coefficients

被引:15
作者
Mann, Kulwinder Singh [1 ]
机构
[1] DAV Coll, Dept Phys, Bathinda 151001, Punjab, India
关键词
Exposure buildup factor; Gamma-ray measurement; Optimum optical thickness; THICKNESS; SAMPLES;
D O I
10.1016/j.nima.2017.08.047
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Scattered photon's influence on measured values of attenuation coefficients (mu(m), cm(2)g(-1)) for six low-Z (effective atomic number) building materials, at three photon energies has been estimated. Narrow-beam transmission geometry has been used for the measurements. Samples of commonly used engineering materials (Cements, Clay, Lime-Stone, Plaster of Paris) have been selected for the present study. Standard radioactive sources Cs-137 and Co-60 have been used for obtaining gamma-ray energies 661.66, 1173.24 and 1332.50 keV. The optical thickness (OT) of 0.5 mfp (mean free path) has been found the optimum optical thickness (OOT) for mu(m)-measurement in the selected energy range (661.66-1332.50 keV). The aim of this investigation is to provide neglected information regarding subsistence of scattered photons in narrow beam geometry measurements for low-Z materials. The measurements have been performed for a wide range of sample-thickness (2-26 cm) such that their OT varies between 0.2-3.5 mfp in selected energy range. A computer program (GRIC2-toolkit) has been used for various theoretical computations required in this investigation. It has been concluded that in selected energy-range, good accuracy in mu(m)-measurement of low-Z materials can be achieved by keeping their sample's OT below 0.5 mfp. The exposure buildup factors have been measured with the help of mathematical-model developed in this investigation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 26 条
  • [1] [Anonymous], 1974, 1128 IS BUR IND STAN
  • [2] [Anonymous], 1729, Essai d'optique sur la gradation de la lumiere. chez Claude Jombert, rue S. Jacques
  • [3] [Anonymous], 1978, 2542 IS BUR IND STAN
  • [4] [Anonymous], 1977, 2720 IS BIS
  • [5] [Anonymous], 1989, 8042 IS BUR IND STAN
  • [6] [Anonymous], 2013, 3812 IS BUR IND STAN
  • [7] [Anonymous], 6431991W2001 ANSIANS
  • [8] Beer, 1852, Ann. Phys, V162, P78, DOI [10.1002/andp.18521620505, DOI 10.1002/ANDP.18521620505]
  • [9] Berger M.J., 1987, XCOM: Photon Cross Sections Database, Web Version 1.2, DOI DOI 10.2172/6016002
  • [10] Effect of detector collimation on the measured mass attenuation coefficients of some elements for 59.5-661.6 keV gamma-rays
    Celik, Necati
    Cevik, Ugur
    Celik, Ahmet
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 281 : 8 - 14