Dynamic simulation and exergetic analysis of a solar thermal collector installation

被引:9
作者
Garcia-Menendez, David [1 ]
Carlos Rios-Fernandez, Juan [1 ]
Maria Blanco-Marigorta, Ana [2 ]
Jose Suarez-Lopez, Maria [1 ]
机构
[1] Univ Oviedo, EDZE Energia, Campus Viesques, Gijon 33203, Asturias, Spain
[2] Univ Las Palmas Gran Canaria, Dept Proc Engn, Tafira Baja S-N, Las Palmas De Gc, Canary Islands, Spain
关键词
Solar thermal collector; Exergetic analysis; TRNSYS dynamic model; Exergetic efficiency; FLAT-PLATE COLLECTORS; WATER-HEATING SYSTEM; PARABOLIC TROUGH COLLECTORS; ENVIRONMENTAL-ANALYSIS; PERFORMANCE; OPTIMIZATION; VALIDATION; MODEL;
D O I
10.1016/j.aej.2021.06.075
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Solar collectors are active solar devices which help reducing the energy consumption in buildings. In this paper, a real installation of solar collectors is analysed under different collector array configurations. Also, both energetic and exergetic analyses have been developed, for both general balance and specific variables. To apply these analyses, a TRNSYS dynamic model has been built and validated with experimental data obtained in the real installation. The values of the representative variables have been examined in different points of the installation, resulting in a description of the installation operation and parameters influencing the exergetic efficiency. Although parallel connections of the collectors are commonly used, in this work, simulations and experiments have been carried out with both parallel and series connections. As a result, no significant differences regarding the array configurations have been found. The values of the exergetic efficiency of the collectors are always very low (within 1% and 4.6%), no matter the configuration nor the irradiance. Its maximum value was reached after about 5 h of operation, for all configurations. The values obtained for the whole installation are in the range of 20-50% for the energetic efficiency, whereas the exergetic efficiency is always lower than 1.5%. (C) 2021 THE AUTHORS. Published by Elsevier BV on behalf of Faculty of Engineering, Alexandria University.
引用
收藏
页码:1665 / 1677
页数:13
相关论文
共 34 条
[1]   Forced-circulation solar water heating system using heat pipe-flat plate collectors: Energy and exergy analysis [J].
Allouhi, A. ;
Benzakour Amine, M. ;
Buker, M. S. ;
Kousksou, T. ;
Jamil, A. .
ENERGY, 2019, 180 :429-443
[2]   Experimental and numerical investigation of a flat-plate solar collector [J].
Alvarez, A. ;
Cabeza, O. ;
Muniz, M. C. ;
Varela, L. M. .
ENERGY, 2010, 35 (09) :3707-3716
[3]   Validated TRNSYS model for forced circulation solar water heating systems with flat plate and heat pipe evacuated tube collectors [J].
Ayompe, L. M. ;
Duffy, A. ;
McCormack, S. J. ;
Conlon, M. .
APPLIED THERMAL ENGINEERING, 2011, 31 (8-9) :1536-1542
[4]   Exergy, economic and environmental analysis of forced circulation flat plate solar collector using heat transfer enhancer in riser tube [J].
Balaji, K. ;
Iniyan, S. ;
Swami, Muthusamy V. .
JOURNAL OF CLEANER PRODUCTION, 2018, 171 :1118-1127
[5]   Development and validation of a detailed TRNSYS-Matlab model for large solar collector fields for district heating applications [J].
Bava, Federico ;
Furbo, Simon .
ENERGY, 2017, 135 :698-708
[6]  
Bejan A., 2006, Advanced engineering thermodynamics
[7]  
Bejan A., 1995, Thermal design and optimization
[8]  
Chamoli S, 2013, J ENERGY SOUTH AFR, V24, P8
[9]   Theoretical and experimental analysis of thermal performance of a solar water heating system with evacuated tube heat pipe collector [J].
Daghigh, Roonak ;
Shafieian, Abdellah .
APPLIED THERMAL ENGINEERING, 2016, 103 :1219-1227
[10]   Exergetic optimization of flat plate solar collectors [J].
Farahat, S. ;
Sarhaddi, F. ;
Ajam, H. .